Order Entry
Italy
ContactUsLinkComponent
 

 

Surfactant, RapiGest™ SF

Supplier: WATERS

RapiGest™ SF is an anionic surfactant for peptide digestion. Supplied as five 1 mg vials for 1 to 50 digestions. The digestion speed and more peptide recovery is enhanced by using trypsin or other enzymes.

Expand 1 Items
 

Analytical HPLC columns, XBridge™ BEH C18

Supplier: WATERS

XBridge™ BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

Expand 5 Items
 

UPLC columns, ACQUITY UPLC™ BEH Shield RP 18

Supplier: WATERS

These columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Expand 2 Items
 

Solid phase extraction cartridges, Oasis® WCX

Supplier: WATERS

These cartridges contain the Oasis® WCX sorbent, which is a polymeric reversed phase, weak ion exchange mixed mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong basic compounds and quaternary amines.

Expand 1 Items
 

Analytical HPLC columns, XTerra® RP18

Supplier: WATERS

XTerra® RP18 columns are general purpose, hybrid-based, reversed phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Expand 5 Items
 

Analytical HPLC columns, XTerra® MS C8

Supplier: WATERS

XTerra® MS C8 columns are general purpose, hybrid-based, reversed phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.

Expand 2 Items
 

Analytical HPLC columns, SunFire™ C8

Supplier: WATERS

SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.

Expand 1 Items
 

Preparative columns, µBondapak® C18

Supplier: WATERS

µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.

Expand 1 Items
 

Solid phase extraction cartridge, Sep-Pak® XPoSure™ Plus

Supplier: WATERS

Specially designed for monitoring aldehydes in indoor air.

Expand 1 Items
 

Columns, ACQUITY UPLC™ HSS T3

Supplier: WATERS

An universal, silica based bonded phase with ACQUITY HSS T3 sorbents which is used for the separations for polar and non-polar compounds. It is compatibility with 100% of aqueous mobile phase. It exhibit ultra-low MS bleed, scalable and transferable to HPLC separations.

Expand 1 Items
 

Solid phase extraction cartridges, Oasis® WAX

Supplier: WATERS

These Oasis® WAX cartridges contain the WAX sorbent, which is a polymeric reversed phase, weak anion exchange mixed mode sorbent that has been optimised for fast, simple, and highly selective sample preparation of strong acidic compounds.

Expand 1 Items
 

Analytical HPLC columns, XTerra® Phenyl

Supplier: WATERS

XTerra® Phenyl columns are hybrid-based, reversed phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

Expand 1 Items
 

Analytical HPLC columns, XBridge™ BEH Shield RP18

Supplier: WATERS

XBridge™ BEH Shield RP18 columns complement the XBridge™ BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Expand 1 Items
 

Analytical HPLC columns, SymmetryShield™ RP18

Supplier: WATERS

SymmetryShield™ columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry® C18 ligand.

Expand 6 Items
 

UPLC columns, ACQUITY UPLC™ BEH C18

Supplier: WATERS

These columns are suitable for a diverse range of analytes. With mobile phase (pH 1 to 12) and temperature (80 °C) compatibility, this trifunctionally-bonded alkyl column is a universal method development tool that can impact the retention, selectivity and sensitivity of ionisable compounds (with mobile phase pH) while delivering low- and high-pH stability for all analyte types.

Expand 1 Items
 

SPE cartridge, Sep-Pak®

Supplier: WATERS

Specially designed for analysing formaldehyde, other aldehydes and ketones in air.

Expand 1 Items
 

Analytical HPLC columns, XTerra® MS C18

Supplier: WATERS

XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.

Expand 7 Items
 

Analytical HPLC columns, µBondapak® Phenyl

Supplier: WATERS

Column type: HPLC column, µBondapak®, Phenyl, Ø int.: 3,90 mm, Length: 300 mm, Pore size: 125 Å, Particle size: 10 µm

Expand 1 Items
 

Reversed phase HPLC columns, µBondapak® C18

Supplier: WATERS

µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.

Expand 5 Items
 

Analytical HPLC columns, Symmetry® C8

Supplier: WATERS

Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.

Expand 4 Items
 

Analytical HPLC columns, XTerra® RP8

Supplier: WATERS

XTerra® RP8 columns are general purpose, hybrid-based, reversed phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Expand 1 Items
 

Columns, ACQUITY UPLC™ CSH C18

Supplier: WATERS

ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.

Expand 1 Items
 

Analytical HPLC columns, SunFire™ C18

Supplier: WATERS

SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.

Expand 9 Items
 

Reversed phase HPLC columns, Atlantis® Silica HILIC

Supplier: WATERS

Atlantis HILIC silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography.

Expand 2 Items
 

Reversed phase HPLC columns, Atlantis® T3

Supplier: WATERS

Atlantis T3 columns are universal, silica based, reversed phase C18 columns that provide balanced retention of polar and hydrophobic molecules and useful for developing separations of polar and non-polar compounds.

Expand 6 Items
 

Snap cap vials

Supplier: WATERS

General use vial, Snap neck, 1,00 ml, Borosilicate glass, Clear, Ø×H: 8×40 mm, Non sterile, Cap included: Yes

Expand 3 Items
 

Peptide standard mixture, MassPREP™

Supplier: WATERS

The MassPREP™ peptide standard mixture is useful for the evaluation of HPLC columns and systems dedicated for peptide separations.

Expand 1 Items
 

Analytical HPLC columns, XBridge™ Phenyl

Supplier: WATERS

XBridge™ Phenyl sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded Phenyl ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability and ultra-low column bleed.

Expand 2 Items
 

PIC (paired ion chromatography) reagents for separation by reverse phase chromatography

Supplier: WATERS

Standards for Ion Pair Chromatography, Paired-ionic chromatography reagent B7, heptane sulfonic acid

Expand 1 Items
 

UPLC columns, ACQUITY UPLC™ BEH phenyl

Supplier: WATERS

These columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds.

Expand 3 Items
 
Recommended for You