Blocking buffers, FirstChoice™
Supplier: G-Biosciences
FirstChoice™ Blocking Buffer is ideal as a first choice for optimization of new assays and systems, or when determining the optimal blocking buffer for elimination of non specific binding sites in ELISA, blotting, immunohistochemistry and other applications. Buffers are conveniently supplied in widely used TBS (Tris-buffered saline at pH 7,5) and PBS (phosphate-buffered saline at pH 7,5) buffers as well as in separate formulations containing Tween® 20 for improving blocking efficiencies.
Expand 4 Items
Urea 8 mol/l in aqueous solution, Proteomics Grade
Supplier: VWR Chemicals
A convenient pre-mixed solution that is easily diluted for buffer preparation under denaturing conditions.Commonly used to denature nucleic acids for electrophoresis and to study the secondary and tertiary structure of proteins. Effective for maintaining DNA in a highly denatured state during sequencing protocols, urea is also useful for accelerating the activity of Proteinase K digestions.
Expand 1 Items
Lysates, bacterial GenLysate™, E.Coli
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 1 Items
PBS and TBS buffers
Supplier: Rockland Immunochemicals
Phosphate buffered and Tris buffered saline are suitable for multiple applications including biological diluent buffer for antibodies or other biologics. Also may be used as a wash buffer for immunological assays including western blot, immunohistochemistry, immunofluorescence microscopy, and ELISA. Other applications may require detergents or other additional components.
Expand 3 Items
VWR® PerfectBlue Twin M, Dual-Gel System
Supplier: VWR Collection
For 16×14 cm gels, the Twin M is a versatile system for SDS PAGE applications, in addition to non denaturing electrophoresis of proteins, SSCPs and dinucleotide repeats. With the enlarged upper buffer chamber, water circulation system and heat-sinking aluminium ceramic plates, the Twin M provides high speed separation while maintaining straight, sharp bands.
Expand 2 Items
Lysates, worm GenLysate™, earthworm
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 1 Items
Lysates, mammalian GenLysate™, pig
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 9 Items
Hybridisation buffers
Supplier: G-Biosciences
The hybridisation buffers like Church & Gilbert’s, Denhardt solution, hybridisation denaturing solution, hybridisation neutralising solution, SSC, SSPE, TMAC Hyb solution and TNT Buffer are used in wide range of applications. Church & Gilbert’s Hybridization Buffer is prepared from molecular biology grade SDS (sodium dodecyl sulfate), monosodium phosphate (NaHPO₄), EDTA (ethylenediaminetetracetic acid) and bovine serum albumin (BSA) Fraction V using DNase, RNase and Protease-free water. It consists of 1mM EDTA, 1% BSA, 0,5M sodium phosphate monobasic, and 7% SDS (at a pH of 7,2).
Expand 15 Items
SSC buffer, 20X concentrate, pH 7,0
Supplier: Rockland Immunochemicals
Saline-sodium citrate (SSC) buffer is most commonly used as a buffer for the hybridisation process and washing in experiments where spcies of nucleic or ribonucleic acid are to be matched to complimentary sequences (such as Southern and Nouthern blotting, in situ hybridisation, or DNA microarrays). SSC is used to help control the stringency of hybridisation in these steps.
Expand 1 Items
Lysates, mammalian GenLysate™, mouse
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 28 Items
Lysates, mammalian GenLysate™, macaque (primate)
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 17 Items
Lysates, insect GenLysate™, Drosophila
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 1 Items
Lysates, plant tissue GenLysate™
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 12 Items
Blocking buffer, fish gelatin
Supplier: Biotium
Fish gelatin is commonly used in blocking solutions to minimise background noise in immunodetection procedures such as Western Blotting and immunostaining. Fish gelatin can be used to block non-specific binding sites on positively charged nylon or PVDF membranes or for blocking and dilution of antibodies during immunostaining procedures. Unlike BSA or milk, fish gelatin does not contain IgG or serum proteins that could cross-react with mammalian antibodies.
Expand 2 Items
Lysates, mammalian GenLysate™, rabbit
Supplier: G-Biosciences
GenLysates™ are total protein tissue and cell lysates that are extracted from the tissue or cell of interest. To inhibit proteolysis, the GenLysates™ are prepared in a lysis buffer containing a complete protease inhibitor cocktail. Each lysate lot is tested by electrophoresis and Western blot analysis.
Expand 9 Items
VWR® shiroGEL vertical 20, Vertical Electrophoresis Systems
Supplier: VWR Collection
The shiroGEL vertical 20 offers application flexibility and is distinguished by its ease of gel casting and set-up, requiring only four screws to secure up to four 20×20 cm gels. This vertical screw clamp technology distributes pressure evenly along the height of gel rather than in the centre to eliminate plate bowing and gel compression, while maintaining a leakproof seal during casting. A built-in inner buffer chamber within the PAGE insert allows set up to be completed without inclusion of an upper buffer chamber. These systems are ideal for 1D and 2D SDS-PAGE, native, preparative, gradient and high resolution nucleic acid electrophoresis.
Expand 2 Items
Stacking buffer (4X)
Supplier: Thermo Fisher Scientific
Electrophoresis, Stacking Buffer, 4X
Expand 2 Items
Nitrocellulose stripping buffer (10X)
Supplier: Thermo Fisher Scientific
Electrophoresis, Nitrocellulose Stripping Buffer, 10X
Expand 2 Items
Tris(hydroxymethyl)aminomethane (TRIS, Trometamol) ≥99.9%, Ultrapure
Supplier: VWR Chemicals
Reagent for stabilisation of buffer formulations and electrophoresis of biological molecules.
Expand 6 Items
Tris(hydroxymethyl)aminomethane (TRIS, Trometamol) ≥99.8%, Proteomics Grade
Supplier: VWR Chemicals
Reagent for stabilisation of buffer formulations and electrophoresis of biological molecules.
Expand 1 Items
Stripping buffer-2 (4X)
Supplier: Thermo Fisher Scientific
Electrophoresis, Stripping buffer, 4X
Expand 2 Items
Stripping buffer (4X)
Supplier: Thermo Fisher Scientific
Electrophoresis, Stripping buffer, 4X
Expand 1 Items
Tris(hydroxymethyl)aminomethane (TRIS, Trometamol) ≥99.8% for biotechnology
Supplier: VWR Chemicals
Reagent for stabilisation of buffer formulations and electrophoresis of biological molecules.
Expand 3 Items
Transfer buffer, Tris-glycine,10X, AccuGENE™
Supplier: LONZA
AccuGENE™ electrophoresis buffers are ready-to-use solutions ideal for a wide range of molecular biology applications.
Expand 1 Items
Tris-Glycine (TG) buffer,, MP Biomedicals
Supplier: MP Biomedicals
Tris-glycine buffer is used for western blotting and gel electrophoresis.
Expand 1 Items
10X TBE buffer, liquid, Corning®
Supplier: Corning
TBE (Tris-Borate-EDTA) has applications in DNA and RNA agarose gel electrophoresis and polyacrylamide gel electrophoresis.
Expand 1 Items
Electrophoresis running buffers, Pierce™
Supplier: Thermo Fisher Scientific
These are space-saving stock solution that is ideal for quickly preparing running buffer used for gel electrophoresis.
Expand 1 Items
Bromophenol blue sodium salt in ACS Reagent grade water 90% (dye content), Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Bromophenol blue has been used in the sample buffer prepared for western blotting. A tracking dye for nucleic acid or protein electrophoresis in agarose or polyacrylamide gels.
Expand 3 Items
Tris-Glycine buffer
Supplier: EDVOTEK
For vertical polyacrylamide gel electrophoresis.
Expand 2 Items
VWR® shiroGEL Modular mini vertical PAGE systems
Supplier: VWR Collection
The shiroGEL mini vertical PAGE system is modular, allowing PAGE and electroblotting to be carried out in the same tank, simply by changing the inserts. The system features inserts for each application, and a common buffer tank in which to run them. Each insert has its own electrode assembly, which connects to the lid of the buffer tank. For safety, the power leads connect directly to the lid. When the lid is removed, power is disconnected from the system. The inserts also have a small pad that fits into position in the lid. This ensures that the lid is always properly placed and aids in its removal. The buffer tank is moulded to prevent separation and leaking. A variety of spacers, combs and other accessories are available to customise the system. All spacers and combs are colour coded or clearly labelled to indicate thickness.