CO₂ incubators with hot air sterilisation and humidity regulation, CBF Series
Supplier: Binder
The CBF series CO₂ incubators are the premium series of CO₂ incubators with humidity control. Units are suitable for all sensitive incubation applications and ensure optimal cell growth in GMP environments. A CBF series CO₂ incubator can be used for complex cultivation experiments or individual environments with hypoxic conditions thanks to the comprehensive range of options and accessories. Units ensure consistent results including in cell-based assays with multiwell plates.
Expand 5 Items
Options for Constant climate chambers with Peltier technology, KBF-S ECO Solid.Line series
Supplier: Binder
Access port with silicone plug - 100 mm, top, KBF-S ECO
Expand 17 Items
Ovens, E 28
Supplier: Binder
Robust space-saving oven/steriliser with hydraulic mechanical thermostat and temperature setting via analogue dial indicator thermometer.
Expand 2 Items

Want to Maximize Stability Tests Flexibility?
Combine KBF PRO and ICH Light Module for Dual Testing Capabilities: Execute ICH Q1B Photostability and ICH Q1A Stability Tests Efficiently.
Constant Climate Chambers, KBF Series
Supplier: Binder
The KBF series is a proven specialist for reliable ICH stability tests in the pharmaceutical industry: the KBF masters all long-term tests, accelerated tests and stress tests. It fulfills all important ICH requirements, from precision to programming and documentation. With flexible water supply options for all installation locations. The units have a stainless-steel inner chamber and proven APT.line™ preheating chamber technology, feature a temperature range of 0 to +70 °C, and humidity range of 10 to 80% RH, the KBF consumes up to 40 % less energy than its predecessor. With optional light modules, the KBF can be converted into an ICH photostability chamber and a plant growth chamber.
Expand 6 Items
Accessories for dynamic climate chambers MKF series
Supplier: Binder
Dry-air purge, for units with humidty regulation, includes connection, suitable for the simulation of current automobile industry standards, MKF 720
Expand 17 Items
Ultra-low temperature freezers, UF V 500 series
Supplier: Binder
These ultra-low temperature freezers ensure the safe storage of samples at –90 °C. They combine outstanding environmental friendliness with low energy consumption, convenient operation and an individual safety concept.
Expand 5 Items
Plant growth chambers, KBWF Series
Supplier: Binder
The KBWF series plant growth chambers are precise units for plant cultivation under the most up-to-date working conditions with optimum climatic conditions. They provide perfect simulation of a wide range of growing environments, the perfect interaction between heat or cold, humidity and light. The design includes variable position daylight cassettes with five daylight luminescence tubes each. Units self-test for comprehensive status analysis.
Expand 2 Items
Services for Ultra-Low Temperature Freezers, UF V Series
Supplier: Binder
Qualification documents. Hard copy IQ/OQ/PQ documents inside folder - supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ - or pressure, depending on unit, For: UF V
Expand 4 Items
Battery Test Chambers with Safety Equipment for Rapid Temperature Changes, LIT MK Series
Supplier: Binder
Battery test chambers from BINDER are ideal for aging, performance, and stress tests performed on lithium-ion cells and modules during quality assurance and battery production. Handling lithium-ion batteries can present a variety of potential hazards. System operators need to evaluate the level of risk and counteract it using an appropriate safety concept. The LIT MK series of temperature test chambers from BINDER provides a controllable temperature range of −40 to +110 °C. The units come with extensive safety equipment as standard so that tests on lithium-ion cells can be performed at an anticipated EUCAR hazard level of 6. To ensure maximum safety, all the chambers in the LIT MK series are fitted with detection and fire suppression equipment as standard.
Expand 2 Items
Accessories for ultra-low temperature freezers, UF V 500
Supplier: Binder
pH-neutral detergent, concentrated, for gentle remove of residual contaminants, 1kg, For: UF V
Expand 37 Items
Accessories for CO₂ incubators with hot air sterilisation CB series
Supplier: Binder
Connection kit N₂
Expand 8 Items
Factory fitted options for CO₂ incubators with hot air sterilisation, CB and CBF series
Supplier: Binder
CELLROLL Set - modular, expandable roller bottle system for cell cultivation, 6 roller bottles, For: CB and CBF series
Expand 13 Items
Factory fitted options for CO₂ incubators with hot air sterilisation, CB-S Solid.Line series
Supplier: Binder
Door hinged on the left - unit door and standard glass inner door with door hinged on the left, For: CB-S
Expand 6 Items
Options for Drying and Heating Chambers, with Forced Convection, M Avantgarde.Line
Supplier: Binder
HEPA air filter - for fresh air supply to unit, filter classification H14 (acc. to. EN 1822-1:2009; 99,995% at 0,3 µm), For: M 56 series Avantgarde.Line
Expand 5 Items
Drying ovens with forced convection, FD series
Supplier: Binder
Universal drying ovens with stainless steel chambers which are ideal for use in the pharmaceutical and chemical industries, biotechnology, medicine and universities. Ovens feature one temperature program ramp, an adjustable TWB class 2 safety device with visual alarm and adjustable ventilation by means of ventilation slide and 50 mm Ø exhaust duct. Fast recovery times after opening the door or air change.
Expand 2 Items
CO₂ incubators with hot air sterilisation, CB series
Supplier: Binder
CO₂ incubators with a built in CO₂ sensor which can be sterilised. Units offer optimum growth conditions for cell cultures and meet demanding requirements for best possible cell growth and maximum sample safety. The ANTI.PLENUM design minimises surfaces due to the seamless, deep-drawn inner chamber without fixtures and featuring an integrated shelf support system. This reduces the risk of contamination, giving less surface area and fewer parts to clean manually, and removes the running costs of consumables. Reliable decontamination is provided by the standard-compliant 180 °C hot air sterilisation routine which completely eliminates contaminants and ensures the inner chamber is completely sterilised.
Expand 6 Items
Incubators with natural convection (BD) or forced convection (BF), Avantgarde.Line
Supplier: Binder
Avantgarde. Line incubators ensure stable and reliable incubation of microbiological cultures and guarantee reproducible results for routine tests in the laboratory – even high batch throughputs and with long-term operation. Avantgarde. Line BD models have natural convection ensuring rapid temperature equalisation after the door is opened. The BF models have forced convection via a fan. The APT.line™ pre-heating chamber technology gives homogeneous temperature distribution, excellent temperature uniformity and low fluctuation. Units up to 115 litres can be stacked on top of each other to save space. The units have 60 mm insulation which lowers energy consumption and increases performance. All models have a stainless steel chamber with an ergonomic door opening system.
Expand 8 Items
Drying ovens with forced convection FED series, Avantgarde.Line
Supplier: Binder
With forced convection and enhanced timer functions, the Avantgarde.Line heating and drying chambers offer quality and process reliability. With a wide temperature range up to 300 °C, these drying ovens can be used in all applications. Short heat up times and large power reserves are ideal for applications in science, research and industry. The APT.line™ preheating chamber technology gives homegeneous temperature distribution and excellent temperature uniformity and fluctuation. Units up to 115 litres can be stacked on top of each other to save space. The units have 60 mm insulation which lowers energy consumption and increases performance. All models have a stainless steel chamber with an ergonomic door opening system.
Expand 4 Items
Refrigerated incubators with Peltier technology, forced convection, KT series
Supplier: Binder
These energy efficient cooled incubators have been designed for use in the temperature range from 4 to 100 °C. They feature a Peltier cooling system for finely controlled cooling down to 4 °C together with powerful conventional heating. The unit has easy to clean stainless steel interior and inner safety glass door. The incubators are ideal for use in microbiology, genetics, zoology, food and beverage industries, medicine, forensics, pharmaceutical and cosmetic industries. USB port for reading data and ethernet interface for communication software APT-COM™ DataControlSystem.
Expand 3 Items
CO₂ incubators with hot air sterilisation, CB-S Solid.Line series
Supplier: Binder
Series CB-S incubators are suitable for routine cell cultivation applications: They are free from contamination due to 180 °C hot air sterilisation and reliable pH stability thanks to the drift-free infrared CO₂ measurement system.
Expand 1 Items
Extended warranty for Binder KT refrigerated incubators
Supplier: Binder
Extended warranty for Binder KT refrigerated incubators
Expand 1 Items
Accessories for Binder incubators
Supplier: Binder
Environmental test chamber
Expand 7 Items
Cooled Incubators, KB Series
Supplier: Binder
The powerful KB Series of cooling incubators for microorganisms are able to incubate with exceptional precision even when fully loaded. Units have a stainless-steel inner chamber, feature proven APT.line™ preheating chamber technology, have a temperature range of 0 to +70 °C, hot-air disinfection routine, and can be programmed for weekend operation with ease. This KB unit consumes as much as 40% less energy than the previous model.
Expand 6 Items
CO₂ incubators with hot air sterilisation, CB-S Solid.Line series
Supplier: Binder
The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination proof due to the 180 °C hot air sterilisation cycle and reliably pH stable thanks to drift-free infrared CO₂ measurements conducted in real time.
Expand 3 Items
Drying ovens with natural convection ED series, Avantgarde.Line
Supplier: Binder
With natural convection, Avantgarde.Line heating and drying chambers offer quality and process reliability. With a wide temperature range up to 300 °C, these drying ovens can be used in all applications. Short heat up times and large power reserves are ideal for applications in science, research and industry. APT.line™ pre-heating chamber technology gives homegeneous temperature distribution and excellent temperature uniformity and fluctuation. Units up to 115 litres can be stacked on top of each other to save space. These units have 60 mm insulation which lowers energy consumption and increases performance. All models have a stainless steel chamber with an ergonomic door opening system.
Expand 4 Items
Accessories for plant growth chambers, KBWF series
Supplier: Binder
Plant growth chamber
Expand 3 Items
Options for Binder KB, KBP PRO, KBF and KBF PRO
Supplier: Binder
Alarm output, zero-voltage, accessible via 3-pin clamping sleeve (max. 24 V - 2.5 A), with acoustic signal that can be switched off, KBF PRO 130, KBF PRO 260, KBF PRO 470, KBF PRO 720, KBF PRO 1060, KBF PRO 1600
Expand 115 Items
Accessories for dynamic climatic chambers, MK Series
Supplier: Binder
Climatic chamber
Expand 41 Items
Cooled Incubators, KB PRO Series
Supplier: Binder
The KB PRO series are powerful cooling incubators with energy-efficient cooling with modern inverter cooling unit. The units with proven APT.line™ preheating chamber technology have a temperature range of -20 to +100 °C and comprehensive programming options. The models have a stainless-steel inner chamber and cover a wide range of applications that extend well beyond incubation. Optional light modules are also available to turn the KB PRO into a chamber for ICH photostability testing or plant growth.