Order Entry
Italy
ContactUsLinkComponent
2-Propanol ≥99.9%, CHROMASOLV™ for LC-MS, Riedel-de Haën™
Flammable
Irritant
2-Propanol ≥99.9%, CHROMASOLV™ for LC-MS, Riedel-de Haën™
   Sustainable Options Available
Certificates
undefined
Flammable
Irritant
2-Propanol ≥99.9%, CHROMASOLV™ for LC-MS, Riedel-de Haën™
   Sustainable Options Available
Certificates

Some Products May Appear Restricted

To ensure a smooth and speedy checkout, please log in to your account. Some items may show as restricted simply because you're not logged in.

If you do not have an account, you can register using our registration webform (https://www.avantorsciences.com/us/en/login/register)

 

If you're still seeing restrictions after logging in, certain products—like chemicals or medical devices—require additional account verification steps to be able to place an order. Some items may additionally require a specific license or customer documentation;  additional documentation will be requested for these items prior to shipment. 

Specifications

  • Environmentally Preferable:
    Safer Human and Environmental Health
  • Environmental certification:
    EPA Safer Chemical Solvent (Green Circle Rating)

Specifications

Specification Test Results

  • Particles > 0,5 µm:
    effective P/ml
  • Assay (GC):
    Min. 99.9 %
  • Non-volatile matter:
    Max. 0.0005 %
  • Water (Karl Fischer):
    Max. 0.05 %
  • Free acid (as C₂H₅COOH):
    Max. 0.001 %
  • Silver (Ag):
    Max. 0.1 ppm
  • Aluminium (Al):
    Max. 0.5 ppm
  • Barium (Ba):
    Max. 0.1 ppm
  • Calcium (Ca):
    Max. 0.1 ppm
  • Cadmium (Cd):
    Max. 0.05 ppm
  • Cobalt (Co):
    Max. 0.02 ppm
  • Chromium (Cr):
    Max. 0.02 ppm
  • Copper (Cu):
    Max. 0.02 ppm
  • Iron (Fe):
    Max. 0.1 ppm
  • Potassium (K):
    Max. 0.1 ppm
  • Magnesium (Mg):
    Max. 0.1 ppm
  • Manganese (Mn):
    Max. 0.02 ppm
  • Sodium (Na):
    Max. 0.1 ppm
  • Nickel (Ni):
    Max. 0.02 ppm
  • Lead (Pb):
    Max. 0.1 ppm
  • Tin (Sn):
    Max. 0.1 ppm
  • Zinc (Zn):
    Max. 0.1 ppm
  • Transmittance at 220 nm:
    Min. 50 %
  • Transmittance at 230 nm:
    Min. 75 %
  • Transmittance from 260 nm:
    Min. 98 %
  • HPLC Gradient at 254 nm:
    Max. 5 mAU
  • Fluorescence (chinin) at 254 nm:
    Max. 1 ppb
  • Fluorescence (chinin) at 365 nm:
    Max. 1 ppb
  • Suitability for the LC-MS:
    complying
  • Vapor Pressure:
    44 mmHg ( 25 °C)
  • Refractive Index:
    n20/D 1.377 (lit.)

Specification Test Results

Related Information

Frequently Bought Together