About this item
Axygen® gel documentation systems easily capture publication quality, 16 bit TIFF images. The systems are quick to set up and have an intuitive user interface for image capture, annotation, and contrast adjustment. Images are easily saved and opened in common gel analysis software for more detailed analysis.
- Auto exposure - no manual manipulation of the camera required
- Ready to use system - just connnect to computer and load the software
- Long-life dual wavelength transilluminators
- Exceptionally high resolution (5,4 MP) camera
- UV cut-off switch to prevent exposure to ultra-violet light if door is opened while the UV light is on
- Transillumination bulbs last for 30000 hours
The darkroom tab allows users to select from UV 302, UV 365, epi white, or epi blue (BL system only) light sources, as well as an optional trans white light illumination tray.
The auto exposure tool calculates the optimal exposure time with one click. The Slider tool can be used to manually adjust the exposure time and view an updated live image. The select ROI tool calculates a region of interest. The auto exposure calculations are only based on the selected region. This feature is especially useful for gels that have either intense or faint bands.
The band excision tool allows the user to temporarily override the safety precautions in the system to view the gel with the light on.
NOTE: Protective eyewear must always be worn when working with UV light.
Imaging tools include crop, rotate, resize, contrast, saturation, and zoom. Annotation tools include a variety of text and drawing tools. Finished images can be saved, printed, emailed, or exported for further analysis.
The BL model has all the features of the standard system, as well as built-in blue lights and a built-on Microsoft® Windows® tablet. The blue lights are designed for use with EtBr replacement dyes to prevent damage to DNA that will be excised for subsequent analysis.
: GD-1000 and GDBL-1000 are CE, cTUVus certified. GD-PRT is CE, cTUVus,UL,FCC certified.
: Microsoft Windows 7 or higher is required and must be ordered separately. Minimum hardware requirements: 1,4 GHz processor speed, 2 GB RAM, 16 GB free hard disk space, 2 USB ports.
: System includes a dual-wavelength transilluminator, 5,4 MP image resolution camera, and image acquisition software. The BL model includes a Windows® tablet computer.
2 Options Available Below
Product Details & Documents
Axygen® gel documentation systems easily capture publication quality, 16 bit TIFF images. The systems are quick to set up and have an intuitive user interface for image capture, annotation, and contrast adjustment. Images are easily saved and opened in common gel analysis software for more detailed analysis.
- Auto exposure - no manual manipulation of the camera required
- Ready to use system - just connnect to computer and load the software
- Long-life dual wavelength transilluminators
- Exceptionally high resolution (5,4 MP) camera
- UV cut-off switch to prevent exposure to ultra-violet light if door is opened while the UV light is on
- Transillumination bulbs last for 30000 hours
The darkroom tab allows users to select from UV 302, UV 365, epi white, or epi blue (BL system only) light sources, as well as an optional trans white light illumination tray.
The auto exposure tool calculates the optimal exposure time with one click. The Slider tool can be used to manually adjust the exposure time and view an updated live image. The select ROI tool calculates a region of interest. The auto exposure calculations are only based on the selected region. This feature is especially useful for gels that have either intense or faint bands.
The band excision tool allows the user to temporarily override the safety precautions in the system to view the gel with the light on.
NOTE: Protective eyewear must always be worn when working with UV light.
Imaging tools include crop, rotate, resize, contrast, saturation, and zoom. Annotation tools include a variety of text and drawing tools. Finished images can be saved, printed, emailed, or exported for further analysis.
The BL model has all the features of the standard system, as well as built-in blue lights and a built-on Microsoft® Windows® tablet. The blue lights are designed for use with EtBr replacement dyes to prevent damage to DNA that will be excised for subsequent analysis.
: GD-1000 and GDBL-1000 are CE, cTUVus certified. GD-PRT is CE, cTUVus,UL,FCC certified.
: Microsoft Windows 7 or higher is required and must be ordered separately. Minimum hardware requirements: 1,4 GHz processor speed, 2 GB RAM, 16 GB free hard disk space, 2 USB ports.
: System includes a dual-wavelength transilluminator, 5,4 MP image resolution camera, and image acquisition software. The BL model includes a Windows® tablet computer.
Specifications for Product Family
Specifications
- Catalog No:
- AXYGGD-1000
- AXYGGDBL-1000
- Lighting:
- Optional trans white light illumination tray
- Optional trans white light illumination tray
- Image area:
- 150×200 mm
- 150×200 mm
- Lens:
- f1.8
- f1.8
- W×D×H:
- 304,8×381×546 mm
- 304,8×381×546 mm
Specifications
Product Family Options
Product Information
- AvailabilityPrice
- AXYGGD-1000Gel documentation system, GD-1000Specifications:
More
Specifications
Cat. No.AXYGGD-1000LightingOptional trans white light illumination trayImage area150×200 mmLensf1.8W×D×H304,8×381×546 mm - AXYGGDBL-1000Gel documentation system-BL, with 3-position filter slide and tablet computer, GDBL-1000Gel documentation system-BL, with 3-position filter slide and tablet computer, GDBL-1000Log in for availability1 * 1 pezzi13 500,00 €Specifications:
More
Specifications
Cat. No.AXYGGDBL-1000LightingOptional trans white light illumination trayImage area150×200 mmLensf1.8W×D×H304,8×381×546 mm
Accessories
Product Information
- Catalog #AvailabilityPrice
- 1 user license of total lab 1D
Product Information
- Catalog #AvailabilityPrice
- Optional green filter (572 nm)
Product Information
- Catalog #AvailabilityPrice
- Optional blue filter (497 nm)
Product Information
- Catalog #AvailabilityPrice
- UV transmitting tray (protects UV transilluminator when cutting out bands)UV transmitting tray (protects UV transilluminator when cutting out bands)AXYGGD-GCSLog in for availability1 * 1 pezzi - 317,00 €
Product Information
- Catalog #AvailabilityPrice
- USB hub
Product Information
- Catalog #AvailabilityPrice
- Orange glasses (reduces background when cutting out bands with blue light)Orange glasses (reduces background when cutting out bands with blue light)AXYGGD-OGLog in for availability1 * 1 pezzi - 189,00 €
Product Information
- Catalog #AvailabilityPrice
- USB mouse and keyboard
Product Information
- Catalog #AvailabilityPrice
- Thermal printer paper
Product Information
- Catalog #AvailabilityPrice
- Blue light conversion screen for GD-1000Blue light conversion screen for GD-1000AXYGGD-BLCSLog in for availability1 * 1 pezzi - 1 190,00 €
Product Information
- Catalog #AvailabilityPrice
- Gel carrying tray for GD-1000 and GDBL-1000Gel carrying tray for GD-1000 and GDBL-1000AXYGGD-GCTLog in for availability1 * 1 pezzi - 315,00 €
Product Information
- Catalog #AvailabilityPrice
- White light conversion screen for GD-1000 and GDBL-1000White light conversion screen for GD-1000 and GDBL-1000AXYGGD-WLCSLog in for availability1 * 1 pezzi - 580,00 €