CO₂ incubators with a built in CO₂ sensor which can be sterilised. Units offer optimum growth conditions for cell cultures and meet demanding requirements for best possible cell growth and maximum sample safety. The ANTI.PLENUM design minimises surfaces due to the seamless, deep-drawn inner chamber without fixtures and featuring an integrated shelf support system. This reduces the risk of contamination, giving less surface area and fewer parts to clean manually, and removes the running costs of consumables. Reliable decontamination is provided by the standard-compliant 180 °C hot air sterilisation routine which completely eliminates contaminants and ensures the inner chamber is completely sterilised.
- Touch screen controller with colour LCD and internal data recording via USB interface
- CO₂ introduction through Venturi gas mixing nozzle
- Electronic error self-diagnostic system with visual and acoustic alarms, as well as a potential free contact for central monitoring
- Independent temperature safety device Class 3.1 (DIN 12880) with visual and audible temperature alarm
- Ethernet interface for APT-COM™ Multi Management Software
- Stable pH values due to short recovery times with drift-free infrared CO₂ measurement system
Uniform growth conditions are provided by the VENTAIR™ jacket system, this ensures accurate temperatures, homogeneous temperature distribution, and enables fast recovery times. It also minimises thermal degradation of cell growth due to occasional door openings, and the Permadry™ double-pan humidification system ensures high humidity and condensate-free interior walls. Units can be stacked using stacking adapter to save space, have a tightly fitted inner glass door made of safety glass and two-point door lock.
- Catalog No:
- 390-1621
- 390-1620
- 390-1617
- 390-1616
- 390-1672
- 390-1624
- Model:
- CB 260
- CB 260
- CB 170
- CB 170
- CB 170
- CB 56
- Temperature fluctuation (time):
- ±0,1 °C @ 37 °C
- ±0,1 °C @ 37 °C
- ±0,1 °C @ 37 °C
- ±0,1 °C @ 37 °C
- ±0,1 °C @ 37 °C
- ±0,1 °C @ 37 °C
- Temperature variation (spatial):
- ±0,3 °C @ 37 °C
- ±0,3 °C @ 37 °C
- ±0,3 °C @ 37 °C
- ±0,3 °C @ 37 °C
- ±0,3 °C @ 37 °C
- ±0,3 °C @ 37 °C
- Recovery time after 30 second door opening at 37 °C:
- 6 min
- 6 min
- 6 min
- 6 min
- 6 min
- 5 min
- Capacity:
- 267 L
- 267 L
- 170 L
- 170 L
- 170 L
- 53 L
- Convection type:
- Air jacket system
- Air jacket system
- Air jacket system
- Air jacket system
- Air jacket system
- Air jacket system
- CO₂ recovery time after 30 second door opening at 5 Vol.% CO₂:
- 5 min
- 5 min
- 5 min
- 5 min
- 5 min
- 5 min
- Shelves supplied (max.):
- (3/8)
- (3/8)
- (3/6)
- (3/6)
- (3/6)
- (2/3)
- Max. load per shelf:
- 10 kg
- 10 kg
- 10 kg
- 10 kg
- 10 kg
- 10 kg
- Max. chamber workload:
- 40 kg
- 40 kg
- 30 kg
- 30 kg
- 30 kg
- 30 kg
- Int. W×D×H:
- 620×575×750 mm
- 620×575×750 mm
- 560×500×600 mm
- 560×500×600 mm
- 560×500×600 mm
- 400×330×400 mm
- Ext. W×D×H:
- 740×785×1020 mm
- 740×785×1020 mm
- 680×718×870 mm
- 680×718×870 mm
- 680×718×870 mm
- 528×545×674 mm
- Energy consumption:
- 65 Wh/h at 37 °C
- 65 Wh/h at 37 °C
- 55 Wh/h at 37 °C
- 55 Wh/h at 37 °C
- 55 Wh/h at 37 °C
- 45 Wh/h at 37 °C
- Nominal power consumption:
- 1500 W
- 1500 W
- 1400 W
- 1400 W
- 1400 W
- 800 W
- Sound level:
- 41 dB(A)
- 41 dB(A)
- 41 dB(A)
- 41 dB(A)
- 41 dB(A)
- 41 dB(A)
- Temperature range:
- Ambient +4…60 °C
- Ambient +4…60 °C
- Ambient +4…60 °C
- Ambient +4…60 °C
- Ambient +4…60 °C
- Ambient +4…60 °C
- Electrical:
- 200/230 V 1~ 50/60 Hz
- 200/230 V 1~ 50/60 Hz
- 200/230 V 1~ 50/60 Hz
- 200/230 V 1~ 50/60 Hz
- 200/230 V 1~ 50/60 Hz
- 200/230 V 1~ 50/60 Hz
- Weight:
- 125 kg
- 125 kg
- 98 kg
- 98 kg
- 98 kg
- 53 kg