You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual solvent polarity, composition, and size. The right chromatography control system allows to automate the delivery of cleaning, sanitizing and conditioning buffers to the packed column, and can enable to cycle the chromatography column several times during the batch, requiring smaller columns and subsequent lower capital investment.
Avantor® ACE® Phenyl-300, HPLC Columns, 3 µm
Supplier: Avantor
These ultra inert Avantor® ACE® Phenyl-300 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
Expand 12 Items
Avantor® Prevail C18-Select, HPLC Columns
Supplier: Avantor
Prevail™ HPLC columns exhibit long column lifetime in both highly aqueous and highly organic mobile phases. All phases, apart from Prevail™ Carbohydrate ES are silica-based. The stability of these phases is such that a single column can be switched between highly aqueous for analysis of highly polar analytes and highly organic for strong retention of hydrophobic analytes.
Expand 8 Items
Vydac 208MS C8, HPLC columns
Supplier: Avantor
Vydac MS columns are a later development from Grace for the reversed phase HPLC separation of biomolecules. A proprietary surface treatment and bonding process give Vydac MS columns unique selectivity. A variety of reversed phases makes this product line suitable for the analysis of small peptides to large intact, undenatured proteins.
Expand 5 Items
Avantor® ACE® PFAS Delay Columns
Supplier: Avantor
Background PFAS (Perfluoronated Alkyl Substances) from an LC instrument and mobile phase can interfere with the detection of PFAS in samples. The introduction of a delay column, which is plumbed before the autosampler in the LC system, will delay background PFAS to improve accuracy of PFAS measurement by LC-MS.
Expand 1 Items
Avantor® Partisil SAX, HPLC Columns
Supplier: Avantor
Avantor® Partisil® was one of the first commercially available irregular silicas with a large surface area giving it a high loading capacity.
Expand 15 Items
Avantor® Hichrom, Retention Gap/Precolumn, CW Deactivated Fused Silica
Supplier: Avantor
CW deactivated fused silica retention gap / precolumn. Deactivation mainly for polar solvents.
Expand 48 Items
Avantor® Hichrom HI-624, GC Columns
Supplier: Avantor
General purpose low to mid polarity phase for a wide range of applications, including (for example): Residual solvents and volatile pollutants.
Expand 150 Items
Vydac 214MS C4, HPLC columns
Supplier: Avantor
These Vydac MS columns are a later development from Grace for the reversed phase HPLC separation of biomolecules. A proprietary surface treatment and bonding process give Vydac MS columns unique selectivity. A variety of reversed phases makes this product line suitable for the analysis of small peptides to large intact, undenatured proteins.
Expand 16 Items
Avantor® Hichrom HI-DEX G-01, GC Columns
Supplier: Avantor
Unique selectivity for the separation of enantiomers. Useful for the analysis of chiral compounds in fragrances, pesticides and pharmaceuticals in which the determination of the ratio of enantiomers in a sample is necessary.
Expand 12 Items
Avantor® Hichrom HI-5 MS, GC Columns
Supplier: Avantor
Really versatile general purpose low-polarity phase for a wide range of applications, including (for example): PCBs, essential oils, pesticides, semivolatiles and many more. HI-5 MS is an MS grade low-bleeding crossbonded column and assure a long lifetime even under high temperature limits.
Expand 148 Items
Avantor® Hichrom HI-1, GC Columns
Supplier: Avantor
Really versatile general purpose apolar phase for a wide range of applications, including (for example): PCBs, simulated distillation, gases, essential oils, hydrocarbons analysis, pesticides, semivolatiles, oxygenates. HI-1 is a crossbonded phase and assure a long lifetime even under high temperature limits.
Expand 161 Items
Vydac 218TP C18, HPLC columns
Supplier: Avantor
Vydac TP is the first range of wide pore media phases developed in the Vydac range and it is the industry's standard for peptide and protein separations. The large pores of the 300 Å TP silica give polypeptide molecules complete access to the interior of the silica pores.
Expand 44 Items
J.T.Baker® BAKERBOND spe™ WP CBX, SPE Columns
Supplier: Avantor
BAKERBOND spe™ columns are disposable PP or glass columns pre-packed with high capacity sorbents contained between two 20 µm PE frits.
Expand 1 Items
Avantor® ACE® SuperC18, HPLC Columns, Microbore, 3 µm
Supplier: Avantor
Avantor® ACE® SuperC18 columns provide high stability across an extended pH range. These stainless steel columns are ideal for use with LC/MS compatible buffers and can be used with both MeOH and MeCN mobile phases.
Expand 4 Items
Avantor® Hichrom HI-35 MS, GC Columns
Supplier: Avantor
Proprietary low polarity and low bleeding stationary phase; great choice for pesticides, herbicides, polychlorinated biphenyls (PCBs), and polyaromatic hydrocarbons (PAHs). Ideal for GC/MS applications and also an excellent choice as a confirmation column for semi-volatile environmental analysis.
Expand 150 Items
Avantor® ACE® C18-300, HPLC Columns, 5 µm
Supplier: Avantor
Avantor® ACE® C18-300 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative. These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules. These columns provide excellent peak shape even at extremely low levels of additives such as TFA, making them ideal for LC/MS applications.
Expand 3 Items
Avantor® ACE® C18-AR, HPLC Columns, 3 µm
Supplier: Avantor
The Avantor® ACE® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
Expand 26 Items
Avantor® ACE® Excel® C18-Amide, HPLC/UHPLC Columns, Analytical, 1,7 µm
Supplier: Avantor
Avantor® ACE® Excel® C18-Amide is a uniquely designed stationary phase offering improved retention of polar compounds, enhanced phenolic resolution and alternative selectivity to C18 bonded columns. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
Expand 8 Items
Avantor® ACE® UltraCore BIO phenyl2, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore BIO Phenyl2 are high performing solid-core (core-shell) particle columns, designed for a range of biomolecule applications. With both 300 Å and 500 Å pore sizes available, optimum pore size can be chosen. This phase is well suited to the analysis of hydrophobic proteins over 5kDa molecular weight with alternative selectivity to C4 bonded phases
Expand 24 Items
Avantor® Partisil Silica, HPLC Columns
Supplier: Avantor
Avantor® Partisil® was one of the first commercially available irregular silicas. A large surface area gives it a high loading capacity. Avantor® Partisil® ion-exchange materials are widely referenced and remain one of the most popular choices for analysts.
Expand 9 Items
Zorbax CN, HPLC Columns
Supplier: Avantor
Zorbax spherical particles are manufactured from small extremely uniform colloidal silica micro beads which are agglutinated in a Du Pont patented organic polymerisation process. The organic polymer is removed by a controlled sintering process to yield mechanically stable silica particles.
Expand 4 Items
Avantor® ACE® UltraCore BIO C4, Analytical HPLC/UHPLC Columns
Supplier: Avantor
Avantor® ACE® UltraCore BIO C4 are high performing solid-core (core-shell) particle columns, designed for a range of biomolecule applications. With both 300 Å and 500 Å pore sizes available, optimum pore size can be chosen. This phase is well suited to the analysis of hydrophobic proteins over 5 kDa molecular weight.
Expand 24 Items
Vydac 201TP C18, HPLC columns
Supplier: Avantor
Vydac TP is the first range of wide pore media phases developed in the Vydac range and it is the industry's standard for peptide and protein separations. The large pores of the 300 Å TP silica give polypeptide molecules complete access to the interior of the silica pores.
Expand 14 Items
Avantor® ACE® UltraCore SuperPhenylHexyl, HPLC/UHPLC Columns, 5 µm
Supplier: Avantor
Avantor® ACE® UltraCore SuperPhenylHexyl solid-core (core-shell) particle columns are ideal for demanding MS work offering improved MS signal intensity and maximum MS response. These stainless steel columns combine high efficiency separations with low column back pressure. The Encapsulated Bonding Technology (EBT™) greatly increases the ligand coverage of the silica surface and effectively eliminates the effect of unbonded silanol groups on separations. This higher ligand coverage results in improved inertness, chromatographic performance and stability.
Expand 12 Items
J.T.Baker® BAKERBOND Speedisk® Hydrophilic DVB, SPE Columns
Supplier: Avantor
These columns feature BAKERBOND® DVB polymer resins, which are the product of ultra-clean polymer microparticle technology. These resin particles have a large surface area, are highly rigid, are stable over pH range 1 to 14, are water-wettable and are not impacted by sorbent drying. These columns are recommended when advanced detection methods are used.
Expand 2 Items
Avantor® ACE® Excel® C18-AR, HPLC/UHPLC Columns, Analytical, 2 µm
Supplier: Avantor
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
Expand 21 Items
Avantor® ACE®, HPLC/UHPLC Columns, HILIC Method Development Kits, Analytical
Supplier: Avantor
Avantor® ACE® HILIC method development kits offer all three Avantor® ACE® proprietary HILIC phases (HILIC-A, HILIC-B and HILIC-N) in one kit. These phases offer alternative HILIC selectivity to each other, and have been developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Expand 28 Items
Avantor® ACE® CN-ES, HPLC Columns, 5 µm
Supplier: Avantor
Avantor® ACE® CN-ES combines CN polar selectivity with enhanced hydrophobicity, enabling the benefits of both interactions to be fully exploited. Extra phase stability and increased column lifetime is provided by an extended alkyl chain spacer between the silica surface and cyano group. Avantor® ACE® CN-ES is suitable for both reversed phase and normal phase separations.
Expand 19 Items
Avantor® ACE® Excel® C18-AR, HPLC/UHPLC Columns, Analytical, 5 µm
Supplier: Avantor
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
Expand 14 Items
J.T.Baker® BAKERBOND® Q2100, New Generation UHPLC and HPLC Columns
Supplier: Avantor
BAKERBOND® Q2100 LC phases have been specially designed to solve the challenges of most routine samples. They can also be a good starting point for new method development projects. With options of four widely used chemistries and three particle sizes BAKERBOND® Q2100 can be a useful addition to your analytical toolkit.