You searched for: Standards
Meeting regulations in any industry, standards are essential for periodically checking the accuracy of equipment pieces. By comparing against the known values, output readings detect errors present and inform personnel adjustments are required. Once the settings of the manual or automatic instruments have returned to zero, the re-established conditions will yield optimal working performance. Calibrating with concentrated standards eliminates the possibility that environmental changes will induce instrumental miscalculation when accuracy matters most.
Nitrite standard solution
Supplier: HACH
For accuracy checks in nitrite determinations.
Expand 1 Items
Carbon dioxide standard solution
Supplier: HACH
Standard solution for accuracy checks in carbon dioxide determinations (Potassium hydrogen phthalate solution).
Expand 1 Items
Iron standard solution
Supplier: HACH
For accuracy checks in iron determinations.
Expand 5 Items
Standard solution, detergent
Supplier: HACH
For accuracy checks in detergents (surfactants) determinations.
Expand 1 Items
Total organic carbon standards
Supplier: HACH
For accuracy checks in total organic carbon (TOC) determinations. Available as 20 ml sealed ampules.
Expand 1 Items
Potassium iodide-iodate standard solution, 0,0125 N
Supplier: HACH
Used for determination of sulphite by burette iodometric titration.
Expand 1 Items
Volatile acid standards
Supplier: HACH
Acetate standard solution for accuracy checks in volatile acids determinations.
Expand 1 Items
Standards for 2100N and 2100N IS
Supplier: HACH
Turbidity Standard, Stablcal® Turbidity Standards Calibration Kit, < 0,1 NTU, 20 NTU, 200 NTU, 1000 NTU, 4000 NTU, Type: Formazine, 5× sealed vial
Expand 3 Items
Chlorine standard solution
Supplier: HACH
For accuracy checks in chlorine determinations. Lot specific concentration displayed on label.
Expand 3 Items
Gelex secondary standards kit for 2100 series turbidity meters
Supplier: HACH
Gelex secondary standards kit for 2100P and 2100Q series portable turbidimeters (includes 1 sealed vial each for 0 to 10 NTU, 10 to 100 NTU, 100 to 1000 NTU).
Expand 4 Items
Quaternary ammonium compound (QAC) standard solution
Supplier: HACH
For accuracy checks in quaternary ammonium compound (QAC) determinations.
Expand 1 Items
Fluoride standard solutions (NIST)
Supplier: HACH
Fluoride standard solution, 2 µg/ml, Matrix: H₂O, Application: Environmental standards, ISE Calibration
Expand 5 Items
BOD standard solutions (NIST)
Supplier: HACH
For accuracy checks in Biochemical Oxygen Demand (BOD) determinations.
Expand 2 Items
Wastewater inorganics quality control standard
Supplier: HACH
These mixed standards are ready to use, no dilutions are required. They contain ammonia nitrogen, nitrate nitrogen, COD, phosphate, sulphate and TOC.
Expand 1 Items
Molybdenum standard solution
Supplier: HACH
Standard solution for accuracy checks in molybdenum determinations.
Expand 2 Items
Nickel standard solution
Supplier: HACH
Standard solution for accuracy checks in nickel determinations.
Expand 1 Items
Formaldehyde standard solution
Supplier: HACH
For accuracy checks in formaldehyde determination.
Expand 1 Items
Turbidity standard, ULR verification kit, Stablcal®
Supplier: HACH
Stablcal® verification kit containing 0.10 NTU, 0.30 NTU, 0.50 NTU, 1.0 NTU standards (100 ml each), sililcone oil, oiling cloth and instructions is used for verification purpose only.
Expand 1 Items
Potassium standard solution
Supplier: HACH
Standard solution for accuracy checks in potassium determinations.
Expand 1 Items
Solution, cobalt chloride, for spectrophotometer
Supplier: HACH
Cobalt chloride solution for spectrophotometer linearisation.
Expand 1 Items
Reagents for determination of ammonia and total kjeldahl nitrogen by the nessler method
Supplier: HACH
For determination of ammonia and total kjeldahl nitrogen by the nessler method. Solutions are available in self-contained dropping bottle.
Expand 3 Items
Nitrification inhibitor for BOD
Supplier: HACH
TCMP - 2-chloro-6 (trichloromethyl) pyridine (N-Serve), coated on an inert substrate.
Expand 3 Items
Rankem®, Secondary Reference Standards for GC
Supplier: RANKEM
Rankem offers a wide range of highly pure & characterised secondary GC reference standards for chromatographic and analytical applications.
Expand 176 Items
ASTM® Colour Standards
Supplier: MILLIPORE
The fluid sampling kit is a complete solution for field-based fluid collection and contamination analysis. The stainless steel sampler assembly plugs into a quick-release valve installed in the system line, which allows a measured quantity of liquid to pass through the monitor. A valved syringe serves as a pump to remove residual liquid from the monitor. Kit is compatible with our 37 mm contamination monitors and matched-weight monitors.
Expand 1 Items
Conductivity standards
Supplier: METTLER TOLEDO
A slight change in temperature usually has a big impact on the conductivity value of a standard solution. A table on every bottle label indicates the conductivity values at the most common measurement temperatures.
During calibration the meter automatically references to this table for temperature compensation. If possible, calibration and measurements should be performed at the same temperature
Expand 1 Items
VWR®, Conductivity standards, NaCl
Supplier: VWR Collection
NaCl standard solutions can be used to calibrate instruments that measure any samples containing NaCl (sodium chloride) as major component, such as seawater, brackish water, etc.
Expand 3 Items
VWR®, Conductivity standards, KCl, referenced at 25 °C
Supplier: VWR Collection
Conductivity standard 1,000 µS/cm (0.007 mol/L; KCl), VWR®, 1000 µS/cm, Reference temperature: 25 °C
Expand 4 Items
VWR® Traceable® One-Shot™, Conductivity standards (CRM)
Supplier: VWR Collection
Traceable® Conductivity Standards are among the most accurate available. They are compatible with all makes of equipment, and can be used in lab or field. Each bottle is labeled for calibrating conductivity (microsiemens/micromhos), resistivity (ohms), and dissolved solids (parts per million).