Order Entry
Ireland
ContactUsLinkComponent
 

385 Results for: "Mass Spectrometry"

Peptide and protein MALDI-MS calibration kit, ProteoMass™, Supelco®

Supplier: Merck

This kit features a convenient selection of pre-qualified standard peptides, proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionisation (MALDI) mass spectrometers.

Expand 1 Items
Loading...
Destaining solution, Blue-OUT™ for mass spectrometry

Destaining solution, Blue-OUT™ for mass spectrometry

Supplier: G-Biosciences

Blue-OUT™ for the removal of Coomassie and fluorescent stain prior to mass spectrometry

Expand 1 Items
Loading...

Pesticide reference standards, Pyridaphenthion, PESTANAL®, analytical standards, Supelco®

Supplier: Merck

Pyridaphenthion may be used as a reference standard for the quantification of pyridaphenthion in biological samples using liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry.

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad

Supplier: Merck

Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.

Expand 1 Items
Loading...

Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®

Supplier: Merck

Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.

Expand 1 Items
Loading...
Perfluorokerosene 50% in PFK low boiling, high boiling for mass spectrometry

Perfluorokerosene 50% in PFK low boiling, high boiling for mass spectrometry

Supplier: Thermo Fisher Scientific

Perfluorokerosene 50% in PFK low boiling, high boiling for mass spectrometry

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Monolinuron

Supplier: Merck

Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).

Expand 1 Items
Loading...

Pesticide reference standard, Ronidazole-d3, VETRANAL(TM), analytical standard, Supelco®

Supplier: Merck

Ronidazole-d₃ may be used internal standard in the determination of avermectins, benzimidazoles and nitroimidazoles residues in bovine muscle tissue using ultra-high performance liquid chromatography coupled with mass spectrometry (UHPLC/MS-MS).

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebutam

Supplier: Merck

Tebutam CRM may also be used as given below:
Optimisation of sample extraction based on QuEChERS and dispersive-solid-phase extraction (d-SPE) clean-up for the multi-residue analysis of 120 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls by liquid and gas chromatography coupled with tandem mass spectrometry (MS/MS)
Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
Determination of 90 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls in honey samples by using QuEChERS combined with dispersive solid-phase extraction (SPME) for sample pre-treatment and liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry for quantitation
Screening and quantification of 569 pesticides in honeysuckle samples by a combination of ultrahigh-performance liquid chromatography (UHPLC) and quadrupole-Orbitrap high-resolution mass spectrometry
Simultaneous determination of 134 pesticide residues in tea samples using d-SPE extraction with a multi-functional filter (MFF) followed by ultra-high performance liquid chromatography (UPLC) and quadrupole time-of-flight mass spectrometry (TOF-MS).

Expand 1 Items
Loading...
Water, BAKER ANALYZED® for LC-MS, J.T.Baker®

Water, BAKER ANALYZED® for LC-MS, J.T.Baker®

Supplier: Avantor

For use in liquid chromatography and mass spectrometry.

    
Expand 2 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Simazine

Supplier: Merck

Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).

Expand 1 Items
Loading...

Organic reference standard, Zearalenone-¹³C₁₈ solution, analytical standard, Supelco®

Supplier: Merck

Zearalenone-¹³C₁₈ may be used as an analytical standard for the determination of zearalenone in animal feed by liquid chromatography combined with tandem mass spectrometry (LC-MS/MS).

Expand 1 Items
Loading...

Organic reference standard, 2,3-Hexanedione, analytical standard, Supelco®

Supplier: Merck

2,3-Hexanedione can be used as an internal standard for the quantitative determination of methylglyoxal present in the tissues of Sprague-Dawley rats using electrospray ionization liquid chromatography coupled with mass spectrometry(ESI/LC/MS).

Expand 1 Items
Loading...

MALDI validation set polystyrene Mp ~700 - 70000, certified reference material, Supelco®

Supplier: Merck

MALDI Standards are suitable for the validation and comparison of MALDI-ToF instruments. Certificates provide MALDI spectra including Mw, Mn and Mp values of select narrow polymers, which differ in molar mass.

Expand 1 Items
Loading...

Organic reference standard, Melamine-13C3, analytical standard, VETRANAL™, Supelco®

Supplier: Merck

Melamine-¹³C₃ may be used as an analytical standard for the determination of melamine in milk powder samples by liquid chromatography-electrospray ionisation-isotope dilution mass spectrometry (LC-ESI-IDMS).

Expand 1 Items
Loading...

Organic reference standard, Leucocrystal Violet-d6, analytical standard, Supelco®

Supplier: Merck

Leucocrystal violet-d₆ might be used as an internal standard in the determination of triphenylmethane dyes in rainbow trout samples using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS).

Expand 1 Items
Loading...

Organic reference standard, Fenofibric acid, analytical standard, Supelco®

Supplier: Merck

Used as a reference standard in determination of fenofibric acid in samples of human plasma using high performance liquid chromatography (HPLC) and liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS).

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Metrafenone

Supplier: Merck

Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).

Expand 1 Items
Loading...

Organic reference standard, Bisphenol E, analytical standard, Supelco®

Supplier: Merck

Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).

Expand 1 Items
Loading...

Tartrazine ≥85% (dye content), Sigma-Aldrich®

Supplier: SIGMA ALDRICH MICROSCOPY

Tartrazine may be used as a reference standard in the determination of tartrazine in food samples using ion-pair liquid chromatography coupled with photodiode-array and electrospray mass spectrometry detector.

Expand 2 Items
Loading...
Multi-element standard solution 1 for ICP, TraceCERT®, Supelco®

Multi-element standard solution 1 for ICP, TraceCERT®, Supelco®

Supplier: Merck

Multi-element standard solution 1 has been used in the analysis of pollutants like trace elements in water using total reflection x-ray fluorescence (TXRF) method and inductively coupled plasma mass spectrometry(ICP-MS).

Expand 1 Items
Loading...

Pesticide reference standard, Febantel, VETRANAL(TM), analytical standard, Supelco®

Supplier: Merck

Febantel might be utilised as a source of reference standard in the determination of febantel in samples of animal feed and pharmaceutical formulations, using high performance liquid chromatography (HPLC) and high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS-MS).

Expand 1 Items
Loading...

2,4,6-Tris(pentafluoroethyl)-1,3,5-triazine

Supplier: Apollo Scientific

Mass spectrometry standard.

Expand 3 Items
Loading...

2,4,6-Tris(trifluoromethyl)-1,3,5-triazine 97%

Supplier: Apollo Scientific

Mass spectrometry standard.

Expand 3 Items
Loading...

Pentafluorophenylhydrazine ≥98.0% (by GC), LiChropur™ derivatisation reagent, for HPLC, Supelco®

Supplier: Merck

Pentafluorophenylhydrazine may be used as a derivatizing agent in the determination of semi-volatile carbonyl compounds in air and human plasma samples, using high-resolution gas chromatography coupled with gas chromatography (HRGC-MS) and liquid chromatography atmospheric-pressure chemical-ionization mass spectrometry (LC-APCI-MS-MS), respectively.

Expand 1 Items
Loading...

Tris(perfluorobutyl)amine for mass spectrometry

Supplier: Apollo Scientific

Tris(perfluorobutyl)amine for mass spectrometry

Expand 3 Items
Loading...
OpenLab CDS Software

OpenLab CDS Software

Supplier: VWR Collection

Agilent OpenLab CDS is the next generation chromatography data system, designed for ease of use and productivity. OpenLab CDS offers the most comprehensive instrument control and data acquisition for Hitachi HPLC and amino acid analysers. In addition, it supports an expanded array of instrumentation from other vendors, for example Agilent LC, GC and LC/MS. Whether you like to control a single instrument or a huge network of different analytical instruments, OpenLab CDS grows with your needs.

Expand 1 Items
Loading...

Tris(perfluorononyl)-s-triazine 95%

Supplier: Apollo Scientific

Mass Spectrometry standard

Expand 1 Items
Loading...

Organic reference standard, Ecamsule, analytical standard, Supelco®

Supplier: Merck

Ecamsule (ECAM) has been used as a reference standard for observing the photo-stability and photo-sensitizing property of the ecamsule that forms a major ingredient in the production of sunscreen products by laser flash photolysis and steady-state HPLC coupled with mass spectrometry method.

Expand 1 Items
Loading...

Mammalian TAP system, interPlay

Supplier: AGILENT

The InterPlay Mammalian TAP system allows you to recover interacting proteins from mammalian cells.

Expand 1 Items
Loading...
Recommended for You