601 Results for: "HICHROM"
HPLC/UHPLC columns, Kromasil® Classic, 100 Å
Supplier: HICHROM
The Kromasil® Classic 100 Å family of products is used to separate and purify molecules of up to 10000 Da. Drug candidates for the pharmaceutical, natural products and API industries are separated and purified using Kromasil® Classic 100 Å columns.
Expand 9 Items
HPLC columns, Kromasil® Classic, 300 Å
Supplier: HICHROM
The Kromasil® classic 300 Å family of products is designed to be the perfect choice for proteins and biomolecules larger than 8 to 10 kDa. This 300 Å material has a narrow pore size distribution that ensures good mass transfer for larger molecules, resulting in narrow peaks and no size-exclusion effects.
Expand 1 Items
HPLC/UHPLC columns for small molecule analysis, HALO® Biphenyl, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 1 Items
HPLC/UHPLC columns for small molecule analysis, HALO® AQ-C18, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 1 Items
Analytical HPLC columns, CIMac™
Supplier: HICHROM
CIMac™ columns are designed for fast, reproducible HPLC monitoring and quantification of large biomolecules such as large proteins (IgG, IgM, PEGylated proteins), viruses (AAV, adenovirus, lentivirus, influenza, bacteriophages), VLPs, exosomes and pDNA for example.
Expand 2 Items
Bulk Silica, Kromasil®
Supplier: HICHROM
Kromasil®, Kromasil C18(w), 10 µm, 100 Å
Expand 4 Items
HPLC/UHPLC columns for small molecule analysis, HALO® Phenyl-Hexyl, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 8 Items
HPLC/UHPLC columns for small molecule analysis, HALO® ES-CN, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 2 Items
HPLC/UHPLC columns for small molecule analysis, HALO® C8, 5 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative Fused-Core particle technology. These particles are formed from a solid core and porous outer shell. HALO® columns provide high efficiencies and separation speeds but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 1 Items
HPLC/UHPLC columns for small molecule analysis, HALO® C18, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 14 Items
HPLC/UHPLC columns for small molecule analysis, HALO® PFP, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 5 Items
HPLC Columns, OPTIMAPACK
Supplier: HICHROM
OPTIMAPAK is a range of HPLC columns which are available in three bonded phases and an unbonded silica phase.
Expand 2 Items
Columns for large biomolecule analysis, CIMmultus™
Supplier: HICHROM
CIMmultus™ columns are based on an innovative monolithic technology. Distinguished by large pores/flow through channels these columns are designed for the production, purification, and analytics of large proteins (IgG, IgM, PEGylated proteins), viruses (AAV, adenovirus, lentivirus, influenza, bacteriophages), VLPs, exosomes and pDNA for example.
Expand 20 Items
HPLC/UHPLC columns for small molecule analysis, HALO®, RP-Amide, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 2 Items
SFC achiral columns, Kromasil®
Supplier: HICHROM
Based on 100 Å pore size, Kromasil® SFC columns give users the opportunity of fast separations. The columns are tailor-made for research, discovery and routine analysis. These columns are now being delivered in diol, silica and fused organo-silane (XT) chemistries for the laboratory scientist to separate a wide range of substances, from non-polar to strongly polar compounds.
Expand 1 Items
Columns, Whelk-O®1
Supplier: HICHROM
These columns exhibit broad versatility comparable to polysaccharide-derived CSPs.
Expand 3 Items
HPLC/UHPLC columns for small molecule analysis, HALO® HILIC, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 7 Items
HPLC/UHPLC columns for small molecule analysis, HALO® Penta-HILIC, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 3 Items
Small and large molecule selectivity toolkits, HALO®
Supplier: HICHROM
HALO® UHPLC and UHPLC columns from Advanced Materials Technology are based on innovative Fused-Core particle technology. These particles are formed from a solid core and porous outer shell. HALO® columns provide high efficiencies and separation speeds but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 8 Items
HPLC/UHPLC columns for small molecule analysis, HALO® C18, 2 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative Fused-Core particle technology. These particles are formed from a solid core and porous outer shell. HALO® columns provide high efficiencies and separation speeds but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 2 Items
HPLC/UHPLC columns for small molecule analysis, HALO® C8, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative fused-core particle technology. These particles are formed from a solid core and porous outer shell. HALO® 2,7 µm columns provide the efficiency and separation speed of sub 2 µm particles but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 5 Items
Disk housings, CIM®
Supplier: HICHROM
Filter holder, Disk housing cylinder, POM, CIM®
Expand 1 Items
HPLC Columns, Ultisil XB-C18
Supplier: HICHROM
Ultisil Series HPLC Columns are based on ultra-pure ( purity >99,999% ) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility.
Expand 1 Items
SPE cartridge, iSPE®-HILIC
Supplier: HICHROM
Designed for operated in positive ionization mode for analysis of standards.
Expand 4 Items
HPLC/UHPLC columns for protein analysis, HALO® C4, 2,7 µm
Supplier: HICHROM
HALO® HPLC and UHPLC columns are based on innovative Fused-Core particle technology. These particles are formed from a solid core and porous outer shell. HALO® columns provide high efficiencies and separation speeds but at approximately half the back pressure for the same column length. This lower pressure means that HALO® columns can be used with conventional HPLC and LC-MS systems, as well as with UHPLC systems.
Expand 2 Items
Chiral columns, Regis Phase
Supplier: HICHROM
Column type: HPLC column, RegisPack, Ø int.: 4,60 mm, Length: 250 mm, Particle Size: 10 µm
Expand 4 Items
HPLC columns, Develosil® ODS-UG
Supplier: HICHROM
Develosil® ODS-UG is the most stable column under alkaline conditions (pH 1 to 10).
Expand 1 Items
CIMmultus HiP2 Plasmid Process Pack 80-80 mL (1x DEAE 611.5114-2, 1x C4 HLD 611.8136-2
Supplier: HICHROM
CIMmultus HiP2 Plasmid Process Pack 80-80 mL (1x DEAE 611.5114-2, 1x C4 HLD 611.8136-2
Expand 1 Items
CIMmultus HiP2 Plasmid Process Pack 800-800 mL (1x DEAE 811.5114-2, 1x C4 HLD 811.8136-2
Supplier: HICHROM
CIMmultus HiP2 Plasmid Process Pack 800-800 mL (1x DEAE 811.5114-2, 1x C4 HLD 811.8136-2