Order Entry
Ireland
ContactUsLinkComponent
1719 results for Chromatography Columns

You searched for: Chromatography Columns

Chromatography Columns

Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual solvent polarity, composition, and size. The right chromatography control system allows to automate the delivery of cleaning, sanitizing and conditioning buffers to the packed column, and can enable to cycle the chromatography column several times during the batch, requiring smaller columns and subsequent lower capital investment.

Sort By

Solid phase extraction cartridges, Bond Elut™ C18 OH

Supplier: VARIAN

Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.

Expand 4 Items
Loading...
Capillary columns, CP-Lowox

Capillary columns, CP-Lowox

Supplier: VARIAN

CP-Lowox offers a unique solution to the chemical and petrochemical industries. It is now possible to analyze trace level oxygenate impurities in gas and liquid hydrocarbon streams.

Expand 2 Items
Loading...
Preparative HPLC cartridges

Preparative HPLC cartridges

Supplier: Agilent

These cartridge columns are with reusable end fittings that have a unique design which makes them easy to install with finger-tight connections.

Expand 52 Items
Loading...
HPLC columns, PLRP-S

HPLC columns, PLRP-S

Supplier: VARIAN

The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.

Expand 41 Items
Loading...
Method development kits

Method development kits

Supplier: Agilent

Agilent offers methods development kits to streamline the column collection process used for medium and high pressure LC systems.

Expand 3 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ AccuCAT

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Supplier: VARIAN

Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CH

Supplier: VARIAN

Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.

Expand 5 Items
Loading...

SampliQ SPE cartridges

Supplier: Agilent

High quality SampliQ SPE (Solid Phase Extraction) products help the user confidently extract and concentrate samples from complex matrices, ensuring fast, accurate, and reproducible results from the very first step. The SampliQ line includes polymers, silica and non-silica options to meet user's specific SPE needs.

Expand 2 Items
Loading...

Columns for large biomolecule analysis, CIMmultus™

Supplier: HICHROM

CIMmultus™ columns are based on an innovative monolithic technology. Distinguished by large pores/flow through channels these columns are designed for the production, purification, and analytics of large proteins (IgG, IgM, PEGylated proteins), viruses (AAV, adenovirus, lentivirus, influenza, bacteriophages), VLPs, exosomes and pDNA for example.

Expand 14 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-U

Supplier: VARIAN

Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ LMS

Supplier: VARIAN

Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PH

Supplier: VARIAN

Bond Elut™ PH is a non-polar bonded silica material which exhibits a different selectivity to alkyl or aliphatic functionalised phases such as C8 or cyclohexyl. The electron density present in the aromatic ring affords an enhancement in the retention of conjugated or aromatic ring-containing analytes due to desirable pi-pi interactions.

Expand 11 Items
Loading...

Analytical HPLC columns, Microsorb™ C18

Supplier: VARIAN

Microsorb™ C18 is an octadecylsilane-covered silica that has been bonded using monofunctional bonding agents under optimised conditions. This material is then endcapped with trimethylsilyl groups to minimise nonspecific binding, maximise mass recoveries and improve peak shape.

Expand 4 Items
Loading...
High temperature columns, VF-5ht and VF-5ht Ultimetal

High temperature columns, VF-5ht and VF-5ht Ultimetal

Supplier: VARIAN

The VF-5ht improves the analysis of high boiling compounds by exhibiting low bleed, even at high temperatures. Based on ultra-low bleed FactorFour technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high-molecular weight compounds.

Expand 14 Items
Loading...

HPLC columns, MetaSil AQ C18

Supplier: VARIAN

The MetaSil AQ materials are based on silica that is highly coated with hydrophobic alkyl chains interspersed with hydrophilic short-chain endcapping groups. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase.

Expand 2 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-E

Supplier: VARIAN

A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PSA

Supplier: VARIAN

Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Plexa PCX

Supplier: VARIAN

Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.

Expand 11 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Certify

Supplier: VARIAN

The Bond Elut™ Certify extraction cartridge utilises a packed bed consisting of a special, non-polar C8 sorbent and a strong cation exchanger (SCX). Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but it is also very effective for extraction of a wide range of compounds from a diverse range of aqueous matrices.

Expand 33 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Diol

Supplier: VARIAN

Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ DEA

Supplier: VARIAN

Bond Elut™ DEA bears some resemblance to Bond Elut™ NH₂ in its properties but with a slightly lower capacity as an anion exchange sorbent. DEA has a moderately non-polar character due to the alkyl side chains on the amino functionality. These groups still afford a medium level of polarity, higher than C₈ but less polar than C₂ or CN-E.

Expand 11 Items
Loading...
Capillary columns, CP-Sil

Capillary columns, CP-Sil

Supplier: VARIAN

The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.

Expand 190 Items
Loading...
Capillary columns, CP-Chirasil-Dex CB

Capillary columns, CP-Chirasil-Dex CB

Supplier: VARIAN

The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.

Expand 3 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PPL

Supplier: VARIAN

Bond Elut™ PPL is a styrene-divinylvenzene (SDVB) polymer that has been modified with a proprietary non-polar surface. PPL will retain even the most polar classes of analytes, including phenols. The large particle size allows ease of flow for viscous or particulate rich water samples, while the high surface area and strong hydrophobicity ensure reproducible extractions with high recoveries upon elution. Bond Elut™ PPL is suitable for EPA Method 528 ‘Determination of Phenols in Drinking Water by SPE and Capillary GC/MS’.

Expand 9 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX

Supplier: VARIAN

Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.

Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 43 Items
Loading...
Capillary columns, CP-Al₂O₃/Na₂SO₄

Capillary columns, CP-Al₂O₃/Na₂SO₄

Supplier: VARIAN

CP-Al₂O₃/Na₂SO₄ is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C₁ to C₅ hydrocarbons in a main stream of C₁ to C₅ hydrocarbons. The Na₂SO₄ deactivation salt provides a polar Al₂O₃ surface, so that unsaturated compounds such as ethylene and acetylene are retained longer. These columns analyse more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al₂O₃ provides increased selectivity and allows all C₁ to C₅ hydrocarbon isomers to be separated. CP-Al₂O₃ operates without the need for sub-ambient cooling.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SCX

Supplier: VARIAN

Bond Elut™ SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut™ PRS, the presence of the benzene ring in the functional group increases the potential for non-polar interactions. This non-polar characteristic becomes particularly important when conducting ion-exchange from aqueous systems, where selectivity towards compounds exhibiting cationic and non-polar character is seen.

Expand 24 Items
Loading...
Sort By
Recommended for You