Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Solid phase extraction cartridges, Bond Elut™ SI
Supplier: VARIAN
Native silica is generally regarded as the most polar SPE sorbent available. Bond Elut™ SI is particularly effective at separating compounds with a very similar structure. Applying the analytes in a non-polar solvent, then increasing the solvent polarity by increasing the concentration of a polar modifier, such as THF or ethyl acetate, delivers effective separations.
Expand 18 Items
Solid phase extraction cartridges, Bond Elut™ NH₂
Supplier: VARIAN
Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.
Expand 24 Items
Solid phase extraction cartridges, Bond Elut™ SAX
Supplier: VARIAN
Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.
Expand 29 Items

Vásárolja meg Acros & Alfa Aesar vegyszereit az Avantor®-tól, hogy optimalizálja laboratóriuma ellátását
Már bízik a Thermo Fisher kiváló minőségű vegyi anyagaiban, valamint az Avantor® kiváló szolgáltatásában és támogatásában. Nos, miért ne kombinálná a kettőt?
Solid phase extraction cartridges, Bond Elut™ C18 OH
Supplier: VARIAN
Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.
Expand 4 Items
Analytical HPLC columns, Microsorb™ C18
Supplier: VARIAN
Microsorb™ C18 is an octadecylsilane-covered silica that has been bonded using monofunctional bonding agents under optimised conditions. This material is then endcapped with trimethylsilyl groups to minimise nonspecific binding, maximise mass recoveries and improve peak shape.
Expand 4 Items
HPLC columns, MetaSil AQ C18
Supplier: VARIAN
The MetaSil AQ materials are based on silica that is highly coated with hydrophobic alkyl chains interspersed with hydrophilic short-chain endcapping groups. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase.
Expand 2 Items
HPLC columns, Pursuit™
Supplier: VARIAN
These Pursuit™ columns are ideal for analysing lead compounds and biological samples. The need for ion pairing agents such as TFA is often eliminated, thus maximising the performance of single and parallel multi-channel LC/MS systems.
Expand 144 Items
Rxi®-1ms Capillary Columns, (Fused Silica)
Supplier: Restek
General purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g. Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ CH
Supplier: VARIAN
Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.
Expand 5 Items
HPLC columns, Polaris™ C8-A
Supplier: VARIAN
These Polaris™ phases have rapid high resolution separations based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 25 Items
HPLC columns, Polaris™ C18-A
Supplier: VARIAN
The Polaris C18-A phase is specially designed for high-throughput and LC/MS analysis of polar analytes in drug discovery, drug metabolism, and AR&D areas.
Expand 48 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
Gel Permeation Chromatography Columns, PL HFIPgel
Supplier: VARIAN
Hexafluoroisopropanol (HFIP) is used as a solvent in GPC for the analysis of important industrial polymers such as polyesters, polyamides and polylactide/glycolide copolymers. For greatly improved performance in extremely polar solvents such as HFIP and trifluoroethanol, we have developed novel 'multipore' technology to produce PL HFIPgel, a PS/DVB packing featuring a monodisperse particle size, high pore volume and high resolution.
Expand 1 Items
Capillary columns, CP-Chirasil-Dex CB
Supplier: VARIAN
The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.
Expand 3 Items
Capillary columns, CP-Sil
Supplier: VARIAN
The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.
Expand 190 Items
Capillary columns, CP-Chirasil Val
Supplier: VARIAN
The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.
Expand 3 Items
Solid phase extraction cartridges, Bond Elut™ AccuCAT
Supplier: VARIAN
Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ Mycotoxin
Supplier: VARIAN
Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.
Expand 1 Items
Solid phase extraction cartridges, EnvirElut™
Supplier: VARIAN
EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.
Expand 6 Items
HPLC columns, Polaris™ C18-ether
Supplier: VARIAN
Polaris™ C18-ether phase has a rapid high resolution separation based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 26 Items
Solid phase extraction cartridges, Bond Elut™ PH
Supplier: VARIAN
Bond Elut™ PH is a non-polar bonded silica material which exhibits a different selectivity to alkyl or aliphatic functionalised phases such as C8 or cyclohexyl. The electron density present in the aromatic ring affords an enhancement in the retention of conjugated or aromatic ring-containing analytes due to desirable pi-pi interactions.
Expand 11 Items
HPLC columns, PLRP-S
Supplier: VARIAN
The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.
Expand 41 Items
Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying
Supplier: VARIAN
Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ Certify
Supplier: VARIAN
The Bond Elut™ Certify extraction cartridge utilises a packed bed consisting of a special, non-polar C8 sorbent and a strong cation exchanger (SCX). Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but it is also very effective for extraction of a wide range of compounds from a diverse range of aqueous matrices.
Expand 33 Items
Solid phase extraction cartridges, Bond Elut™ Diol
Supplier: VARIAN
Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ LMS
Supplier: VARIAN
Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ C18
Supplier: VARIAN
Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.
Expand 43 Items
Solid phase extraction cartridges, Bond Elut™ PSA
Supplier: VARIAN
Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ CN-U
Supplier: VARIAN
Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.
Expand 4 Items
High temperature columns, VF-5ht and VF-5ht Ultimetal
Supplier: VARIAN
The VF-5ht improves the analysis of high boiling compounds by exhibiting low bleed, even at high temperatures. Based on ultra-low bleed FactorFour technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high-molecular weight compounds.