You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
HPLC columns for carbohydrate analysis, Hi-Plex
Supplier: VARIAN
Hi-Plex HPLC columns deliver improved efficiency, lower operating pressures and longer column lifetimes from monodispersed materials. With a range of ligand counter ions for optimum selectivity and resolution and materials matched to the USP definitions of media types L17, L19, L34 and L58, the Hi-Plex range is ideal for isocratic separations using water or dilute acid as the eluent. This simplifies your HPLC system requirements and eliminates the use of potentially hazardous organic solvents.
Expand 25 Items
Diatomaceous earth sorbents, Chem Elut™ and Hydromatrix™
Supplier: VARIAN
Chem Elut sorbent for rapid, general sample preparation of biological samples such as plasma, serum, whole blood and urine. Chem Elut products are available in buffered and unbuffered formats. The buffered devices can be used for simple scrubbing operations on organic reactions. The base-treated cartridge can remove residual acid compounds from a variety of matrices.
Expand 18 Items

Vásárolja meg Acros & Alfa Aesar vegyszereit az Avantor®-tól, hogy optimalizálja laboratóriuma ellátását
Már bízik a Thermo Fisher kiváló minőségű vegyi anyagaiban, valamint az Avantor® kiváló szolgáltatásában és támogatásában. Nos, miért ne kombinálná a kettőt?
Solid phase extraction cartridges, Bond Elut™ Focus
Supplier: VARIAN
Bond Elut™ Focus solid phase extraction cartridges with enhanced polar recovery. Features a unique amide functionalised polar-enhanced sorbent technology that delivers outstanding retention for polar and non-polar analytes.
Expand 4 Items
Analytical guard column, Upchurch Scientific®
Supplier: UPCHURCH SCIENTIFIC
This narrow-bore short column (2,0×20 mm) creates only a slight pressure increase with virtually no detectable theoretical plate loss when used with a 3 mm int.Ø or larger column.
Expand 1 Items
HPLC columns, Polaris™ amide C18
Supplier: VARIAN
Polaris™ amide C18 has the greatest polarity of the Polaris™ C18 family. The amide polar groups offer a different selectivity from either the C18-A or C18-ether phases. The surface has been covalently modified with alkyl amide groups and endcapped.
Expand 32 Items
Capillary columns, VF-17ms
Supplier: VARIAN
VF-17ms is a 50% phenyl, 50% dimethylpolysiloxane, medium polarity, low bleed column for increased sensitivity, accuracy and instrument uptime.
Expand 20 Items
PLOT columns, CP-PoraPLOT U and CP-PoraPLOT S
Supplier: VARIAN
CP-PoraPLOT U and CP-PoraPLOT S provide symmetrical peaks from polar and non-polar volatiles for ultimate accuracy.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ PCB
Supplier: VARIAN
Bond Elut™ PCB is a specially designed sorbent which allows for the facile extraction of polychlorinated biphenyl (PCB) compounds from a variety of matrices. Desired analytes can be loaded and eluted using a simple, single solvent method prior to analysis by GC/ECD.
Expand 1 Items
Capillary columns, CP-Sil 88 for FAME
Supplier: VARIAN
Guaranteed analysis of FAME cis/trans isomers for complete confidence.
Expand 3 Items
Solid phase extraction cartridges, EnvirElut™
Supplier: VARIAN
EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.
Expand 6 Items
Analytical HPLC columns, Microsorb™ C18
Supplier: VARIAN
Microsorb™ C18 is an octadecylsilane-covered silica that has been bonded using monofunctional bonding agents under optimised conditions. This material is then endcapped with trimethylsilyl groups to minimise nonspecific binding, maximise mass recoveries and improve peak shape.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ C2
Supplier: VARIAN
Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.
Expand 10 Items
HPLC columns, MetaSil AQ C18
Supplier: VARIAN
The MetaSil AQ materials are based on silica that is highly coated with hydrophobic alkyl chains interspersed with hydrophilic short-chain endcapping groups. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase.
Expand 2 Items
HPLC columns, Pursuit™
Supplier: VARIAN
These Pursuit™ columns are ideal for analysing lead compounds and biological samples. The need for ion pairing agents such as TFA is often eliminated, thus maximising the performance of single and parallel multi-channel LC/MS systems.
Expand 144 Items
HPLC columns, Polaris™ C8-A
Supplier: VARIAN
These Polaris™ phases have rapid high resolution separations based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 25 Items
HPLC columns, Polaris™ C18-A
Supplier: VARIAN
The Polaris C18-A phase is specially designed for high-throughput and LC/MS analysis of polar analytes in drug discovery, drug metabolism, and AR&D areas.
Expand 48 Items
Solid phase extraction cartridges, Bond Elut™ ENV
Supplier: VARIAN
Bond Elut™ ENV, a PS/DVB polymer, is designed for the extraction of polar organic residues. It contains 125 μm spherical particles with a high degree of cross linking, advantageous for high volume, fast flow-through applications.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ Alumina
Supplier: VARIAN
Alumina, like silica, is an extremely polar sorbent. The alumina surface tends to be slightly more stable under high pH conditions than unfunctionalised silica. The small particle size of the Bond Elut™ Alumina range ensures high extraction efficiency even when small bed masses are used.
Expand 18 Items
HPLC columns, PLRP-S
Supplier: VARIAN
The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.
Expand 41 Items
Gel Permeation Chromatography Columns, PL HFIPgel
Supplier: VARIAN
Hexafluoroisopropanol (HFIP) is used as a solvent in GPC for the analysis of important industrial polymers such as polyesters, polyamides and polylactide/glycolide copolymers. For greatly improved performance in extremely polar solvents such as HFIP and trifluoroethanol, we have developed novel 'multipore' technology to produce PL HFIPgel, a PS/DVB packing featuring a monodisperse particle size, high pore volume and high resolution.
Expand 1 Items
Capillary columns, CP-Chirasil-Dex CB
Supplier: VARIAN
The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.
Expand 3 Items
Capillary columns, CP-Chirasil Val
Supplier: VARIAN
The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.
Expand 3 Items
Capillary columns, CP-Sil
Supplier: VARIAN
The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.
Expand 190 Items
Solid phase extraction cartridges, Bond Elut™ AccuCAT
Supplier: VARIAN
Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ Mycotoxin
Supplier: VARIAN
Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.
Expand 1 Items
HPLC columns, Polaris™ C18-ether
Supplier: VARIAN
Polaris™ C18-ether phase has a rapid high resolution separation based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 26 Items
Solid phase extraction cartridges, Bond Elut™ CH
Supplier: VARIAN
Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ LMS
Supplier: VARIAN
Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying
Supplier: VARIAN
Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.