Order Entry
Hungary
ContactUsLinkComponent
1399 results for Chromatography Columns

You searched for: Chromatography Columns

Chromatography Columns

Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.

Sort By

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Loading...
HPLC columns for carbohydrate analysis, Hi-Plex

HPLC columns for carbohydrate analysis, Hi-Plex

Supplier: VARIAN

Hi-Plex HPLC columns deliver improved efficiency, lower operating pressures and longer column lifetimes from monodispersed materials. With a range of ligand counter ions for optimum selectivity and resolution and materials matched to the USP definitions of media types L17, L19, L34 and L58, the Hi-Plex range is ideal for isocratic separations using water or dilute acid as the eluent. This simplifies your HPLC system requirements and eliminates the use of potentially hazardous organic solvents.

Expand 25 Items
Loading...
Diatomaceous earth sorbents, Chem Elut™ and Hydromatrix™

Diatomaceous earth sorbents, Chem Elut™ and Hydromatrix™

Supplier: VARIAN

Chem Elut sorbent for rapid, general sample preparation of biological samples such as plasma, serum, whole blood and urine. Chem Elut products are available in buffered and unbuffered formats. The buffered devices can be used for simple scrubbing operations on organic reactions. The base-treated cartridge can remove residual acid compounds from a variety of matrices.

Expand 18 Items
Loading...
466450SF.jpg
Fedezze fel az Alfa Aesa és Arcor termékeit nálunk!

Vásárolja meg Acros & Alfa Aesar vegyszereit az Avantor®-tól, hogy optimalizálja laboratóriuma ellátását

Már bízik a Thermo Fisher kiváló minőségű vegyi anyagaiban, valamint az Avantor® kiváló szolgáltatásában és támogatásában. Nos, miért ne kombinálná a kettőt?

Vásároljon most!

Solid phase extraction cartridges, Bond Elut™ Focus

Supplier: VARIAN

Bond Elut™ Focus solid phase extraction cartridges with enhanced polar recovery. Features a unique amide functionalised polar-enhanced sorbent technology that delivers outstanding retention for polar and non-polar analytes.

Expand 4 Items
Loading...
Analytical guard column, Upchurch Scientific®

Analytical guard column, Upchurch Scientific®

Supplier: UPCHURCH SCIENTIFIC

This narrow-bore short column (2,0×20 mm) creates only a slight pressure increase with virtually no detectable theoretical plate loss when used with a 3 mm int.Ø or larger column.

Expand 1 Items
Loading...
HPLC columns, Polaris™ amide C18

HPLC columns, Polaris™ amide C18

Supplier: VARIAN

Polaris™ amide C18 has the greatest polarity of the Polaris™ C18 family. The amide polar groups offer a different selectivity from either the C18-A or C18-ether phases. The surface has been covalently modified with alkyl amide groups and endcapped.

Expand 32 Items
Loading...
Capillary columns, VF-17ms

Capillary columns, VF-17ms

Supplier: VARIAN

VF-17ms is a 50% phenyl, 50% dimethylpolysiloxane, medium polarity, low bleed column for increased sensitivity, accuracy and instrument uptime.

Expand 20 Items
Loading...
PLOT columns, CP-PoraPLOT U and CP-PoraPLOT S

PLOT columns, CP-PoraPLOT U and CP-PoraPLOT S

Supplier: VARIAN

CP-PoraPLOT U and CP-PoraPLOT S provide symmetrical peaks from polar and non-polar volatiles for ultimate accuracy.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PCB

Supplier: VARIAN

Bond Elut™ PCB is a specially designed sorbent which allows for the facile extraction of polychlorinated biphenyl (PCB) compounds from a variety of matrices. Desired analytes can be loaded and eluted using a simple, single solvent method prior to analysis by GC/ECD.

Expand 1 Items
Loading...
Capillary columns, CP-Sil 88 for FAME

Capillary columns, CP-Sil 88 for FAME

Supplier: VARIAN

Guaranteed analysis of FAME cis/trans isomers for complete confidence.

Expand 3 Items
Loading...

Solid phase extraction cartridges, EnvirElut™

Supplier: VARIAN

EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.

Expand 6 Items
Loading...

Analytical HPLC columns, Microsorb™ C18

Supplier: VARIAN

Microsorb™ C18 is an octadecylsilane-covered silica that has been bonded using monofunctional bonding agents under optimised conditions. This material is then endcapped with trimethylsilyl groups to minimise nonspecific binding, maximise mass recoveries and improve peak shape.

Expand 4 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C2

Solid phase extraction cartridges, Bond Elut™ C2

Supplier: VARIAN

Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.

Expand 10 Items
Loading...

HPLC columns, MetaSil AQ C18

Supplier: VARIAN

The MetaSil AQ materials are based on silica that is highly coated with hydrophobic alkyl chains interspersed with hydrophilic short-chain endcapping groups. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase.

Expand 2 Items
Loading...
HPLC columns, Pursuit™

HPLC columns, Pursuit™

Supplier: VARIAN

These Pursuit™ columns are ideal for analysing lead compounds and biological samples. The need for ion pairing agents such as TFA is often eliminated, thus maximising the performance of single and parallel multi-channel LC/MS systems.

Expand 144 Items
Loading...
HPLC columns, Polaris™ C8-A

HPLC columns, Polaris™ C8-A

Supplier: VARIAN

These Polaris™ phases have rapid high resolution separations based on ultra pure silica to which alkyl chains and polar modifications are attached.

Expand 25 Items
Loading...
HPLC columns, Polaris™ C18-A

HPLC columns, Polaris™ C18-A

Supplier: VARIAN

The Polaris C18-A phase is specially designed for high-throughput and LC/MS analysis of polar analytes in drug discovery, drug metabolism, and AR&D areas.

Expand 48 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ ENV

Supplier: VARIAN

Bond Elut™ ENV, a PS/DVB polymer, is designed for the extraction of polar organic residues. It contains 125 μm spherical particles with a high degree of cross linking, advantageous for high volume, fast flow-through applications.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Alumina

Supplier: VARIAN

Alumina, like silica, is an extremely polar sorbent. The alumina surface tends to be slightly more stable under high pH conditions than unfunctionalised silica. The small particle size of the Bond Elut™ Alumina range ensures high extraction efficiency even when small bed masses are used.

Expand 18 Items
Loading...
HPLC columns, PLRP-S

HPLC columns, PLRP-S

Supplier: VARIAN

The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.

Expand 41 Items
Loading...

Gel Permeation Chromatography Columns, PL HFIPgel

Supplier: VARIAN

Hexafluoroisopropanol (HFIP) is used as a solvent in GPC for the analysis of important industrial polymers such as polyesters, polyamides and polylactide/glycolide copolymers. For greatly improved performance in extremely polar solvents such as HFIP and trifluoroethanol, we have developed novel 'multipore' technology to produce PL HFIPgel, a PS/DVB packing featuring a monodisperse particle size, high pore volume and high resolution.

Expand 1 Items
Loading...
Capillary columns, CP-Chirasil-Dex CB

Capillary columns, CP-Chirasil-Dex CB

Supplier: VARIAN

The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.

Expand 3 Items
Loading...
Capillary columns, CP-Chirasil Val

Capillary columns, CP-Chirasil Val

Supplier: VARIAN

The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.

Expand 3 Items
Loading...
Capillary columns, CP-Sil

Capillary columns, CP-Sil

Supplier: VARIAN

The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.

Expand 190 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ AccuCAT

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Supplier: VARIAN

Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Mycotoxin

Supplier: VARIAN

Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.

Expand 1 Items
Loading...
HPLC columns, Polaris™ C18-ether

HPLC columns, Polaris™ C18-ether

Supplier: VARIAN

Polaris™ C18-ether phase has a rapid high resolution separation based on ultra pure silica to which alkyl chains and polar modifications are attached.

Expand 26 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CH

Supplier: VARIAN

Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.

Expand 5 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ LMS

Supplier: VARIAN

Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Loading...
Sort By
Recommended for You