You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX
Supplier: VARIAN
Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.
Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ PPL
Supplier: VARIAN
Bond Elut™ PPL is a styrene-divinylvenzene (SDVB) polymer that has been modified with a proprietary non-polar surface. PPL will retain even the most polar classes of analytes, including phenols. The large particle size allows ease of flow for viscous or particulate rich water samples, while the high surface area and strong hydrophobicity ensure reproducible extractions with high recoveries upon elution. Bond Elut™ PPL is suitable for EPA Method 528 ‘Determination of Phenols in Drinking Water by SPE and Capillary GC/MS’.
Expand 9 Items
Guard columns, MetaGuard®
Supplier: VARIAN
These MetaGuard columns are stand-alone, disposable guard columns that easily connect directly into the end fitting analytical columns.
Expand 28 Items

Vásárolja meg Acros & Alfa Aesar vegyszereit az Avantor®-tól, hogy optimalizálja laboratóriuma ellátását
Már bízik a Thermo Fisher kiváló minőségű vegyi anyagaiban, valamint az Avantor® kiváló szolgáltatásában és támogatásában. Nos, miért ne kombinálná a kettőt?
Columns and standards for GPC/SEC
Supplier: VARIAN
Column type: HPLC column, PS calibration kit, S-M-10, 10×0,5 g
Expand 14 Items
Guard column cartridges, Chromoguard®
Supplier: VARIAN
Column type: HPLC column, High capacity guard column cartridge, silica, Ø int.: 3,00 mm, Length: 50 mm
Expand 12 Items
Capillary columns, Select Biodiesel
Supplier: VARIAN
Select Biodiesel columns address the key challenge of good column lifetime when operating at very high temperatures up to 400 °C.
Expand 7 Items
Capillary columns, CP-Sil PAH CB UltiMetal
Supplier: VARIAN
The UltiMetal CP-Sil PAH CB column combines the advantages of a highly thermo-stable stationary phase with UltiMetal as the column material.
Expand 1 Items
Capillary columns, CP-Sil 8 CB for pesticides
Supplier: VARIAN
CP-Sil 8 CB delivers a linear column response down to femtogram levels.
Expand 2 Items
Capillary columns, VF-5 Pesticides and VF-1701 Pesticides
Supplier: VARIAN
These columns are specially designed for the determination of trace levels of pesticide residue.
Expand 6 Items
Capillary columns, CP-SimDist
Supplier: VARIAN
CP-SimDist Fused Silica columns are guaranteed for simulated distillation up to C100.
Expand 4 Items
GC columns, J&W CP-1301
Supplier: VARIAN
Agilent JW CP-1301 is a medium polarity column ideal for the analysis of herbicides, pesticides, and many pharmaceutical products.
Expand 3 Items
Capillary columns, CP-TAP CB for triglycerides
Supplier: VARIAN
CP-TAP CB is available in special fused silica for maximum column strength at temperatures up to 370 °C, or UltiMetal capillary for the ultimate robustness.
Expand 2 Items
Capillary columns, CarboBOND and CarboPLOT P7
Supplier: VARIAN
These carbon-based PLOT columns offer a simplified solution for ASTM D 2505, which describes the measurement of ppm CO and CO₂ in ethylene and propylene streams.
Expand 6 Items
Capillary columns, CP-TCEP for alcohols in gasoline
Supplier: VARIAN
CP-TCEP column is able to separate benzene after n-dodecane. In addition, the excellent separation power provides the necessary resolution for complex mixtures such as gasoline.
Expand 2 Items
HPLC columns, OmniSpher™ C18
Supplier: VARIAN
OmniSpher™ is an ultra-high bonded silica designed for the analysis of mixtures containing either acidic or basic functionality that would normally tail on more traditional columns.
Expand 5 Items
Capillary columns, VF-Xms
Supplier: VARIAN
VF-Xms delivers the ultimate in sensitivity and signal-to-noise ratio, and is the low bleed, more polar alternative.
Expand 8 Items
Capillary columns, PLOT
Supplier: VARIAN
Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 to C5 hydrocarbons in a main stream of C1 to C5 hydrocarbons.
Expand 10 Items
HPLC columns, MonoChrom® C18
Supplier: VARIAN
MonoChrom® columns are ideal for separation of organic amines, organic acids, amphoteric compounds and neutral compounds. Advanced silica production and silane bonding techniques allow for the production of material with exceptional base-deactivated characteristics.
Expand 14 Items
Empty solid phase extraction cartridges with two frits, Bond Elut™
Supplier: VARIAN
Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.
Expand 7 Items
GC columns J&W CP-Wax 52 CB
Supplier: VARIAN
CP-Wax 52 provides higher resolution of low boiling point analytes, and is ideal for a variety of EPA and ASTM methods.
Expand 13 Items
HPLC columns, Polaris™ C8-ether
Supplier: VARIAN
These Polaris™ phases have rapid high resolution separations based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 18 Items
Columns, MicroBore
Supplier: VARIAN
The microbore columns are ideal for use with detectors requiring low flow rates such as some mass
spectrometers and with capillary LC systems. Easily accommodates high temperatures for better selectivity and resolution between impurities and the target oligo.
Expand 14 Items
Preparative HPLC columns, SepTech™ C18 reverse phase media
Supplier: VARIAN
SepTech™ media has been developed specifically for prep to process HPLC. The high level of batch-to-batch reproducibility and particle integrity give consistent performance and ease of column packing, which are essential for minimising production downtime.
Expand 14 Items
Preparative HPLC columns, PLRP-S
Supplier: VARIAN
The PLRP-S media, rigid poly(styrene/divinylbenzene) particles, are available in a range of pore sizes for small molecule, synthetic biomolecule and macromolecule purification. Their thermal and chemical stability makes them ideal for purifications that require extreme conditions for sample preparation, compound elution and column regeneration
Expand 68 Items
Capillary columns, CP-Sil 5 CB for Formaldehyde
Supplier: VARIAN
CP-Sil 5 CB for Formaldehyde is optimized for the analysis of formaldehyde, water and methanol, and can deliver trace analysis of sulfur compounds and partial permanent gases.
Expand 2 Items
Capillary columns, CP-Wax 57 CB
Supplier: VARIAN
CP-Wax 57 CB for Glycols and Alcohols is guaranteed for the analysis of glycols, diols and alcohols. It has a unique, high polarity wax phase that produces symmetrical peaks.
Expand 2 Items
Capillary columns, CP-Sil 5/C₁₈ CB for PCB
Supplier: VARIAN
CP-Sil 5/C₁₈ CB for PCB has a lower polarity than 100% polydimethylsiloxane due to its C₁₈ substitutions. Due to the absence of cyano groups it provides high signal-to-noise ratios for ECD detectors.
Expand 2 Items
Solid phase extraction cartridges, Bond Elut™ C2
Supplier: VARIAN
Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.
Expand 10 Items
Solid phase extraction cartridges, Bond Elut™ C18
Supplier: VARIAN
Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.
Expand 43 Items
PLOT columns, CP-PoraPLOT Q and CP-PoraPLOT Q-HT
Supplier: VARIAN
CP-PoraPLOT Q is recommended for column switching systems that analyze polar and apolar volatile compounds.