You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Flash chromatography cartridges, CHROMABOND® Flash RS
Supplier: MACHEREY-NAGEL
These ready-to-use Flash cartridges are designed for use in the Teledyne Isco® Companion® and other Teledyne Isco® CombiFlash® systems without additional connectors or capillaries or as stand-alone version for any pump/detector combinations.
Expand 57 Items
HPLC columns, biochemical analysis, NUCLEOGEL® RP
Supplier: MACHEREY-NAGEL
Polymer based reversed phase columns for biochemical applications.
Expand 7 Items
Capillary columns, Elite-SimDist for autosystem
Supplier: PerkinElmer
Elite-SimDist Dimethylpolysiloxane capillary columns processed for simulated distillation.
Expand 1 Items
Capillary columns, Elite-1ht for autosystem
Supplier: PerkinElmer
The Elite-1ht columns are 100% dimethyl polysiloxane and come in a variety of sizes.
Expand 1 Items
Capillary columns, Elite-WAX for autosystem
Supplier: PerkinElmer
Elite-WAX Polyethylene Glycol capillary columns are ideal for the analysis of polar compounds.
Expand 20 Items
Capillary columns, fused silica
Supplier: MACHEREY-NAGEL
The retention gap technique in combination with on-column injection allows concentration of a large sample volume in the capillary column. The retention gap depends on the solvent used:
Expand 52 Items
Capillary columns, Elite-TPH for autosystem
Supplier: PerkinElmer
Elite-TPH specialty phase capillary columns are ideal for the analysis of total petroleum hydrocarbons.
Expand 1 Items
Reversed phase HPLC columns, PRP-3
Supplier: HAMILTON BONADUZ
PRP-3 polymeric reversed phase columns are ideal for gradient separations of peptides and proteins. The columns are packed with a poly(styrene-divinyl)benzene support.
Expand 17 Items
HPLC columns, Cogent Diol™
Supplier: MICROSOLV
These useful HPLC columns are TYPE-C™ silica columns and have a single, direct silicon-carbon point attachment to the silica-hydride surface.
Expand 22 Items
Capillary columns, Elite-17 for autosystem
Supplier: PerkinElmer
Elite-17 (50% Phenyl) Methylpolysiloxane series capillary columns are ideal for confirmation analysis and are inert for active compounds.
Expand 9 Items
CHROMABOND® C18 SPE Columns
Supplier: MACHEREY-NAGEL
CHROMABOND® C18 is an octadecyl modified silica phase for SPE.
Expand 15 Items
Capillary columns, OPTIMA® XLB
Supplier: MACHEREY-NAGEL
Nonpolar silarylene GC phase with low bleeding for envrionmental analysis.
Expand 2 Items
Anion exchange HPLC columns, NUCLEOGEL® Anion I
Supplier: MACHEREY-NAGEL
This strongly basic polymer-based anion exchange column is used for the analysis of inorganic anions. Contrary to silica-based phase the column is also suited for fluoride analysis.
Expand 1 Items
PE™ C18 Analytical HPLC Columns
Supplier: MICROSOLV
This polar embedded stable C18 column is useful when very high aqueous content mobile phases are required for retention of hydrophobic compounds.
Expand 1 Items
Capillary columns, OPTIMA® 5 HT
Supplier: MACHEREY-NAGEL
Nonpolar silarylene GC phase with low bleeding and high temperature stability.
Expand 8 Items
SPE columns, AOX analysis, CHROMABOND® HR-P-AOX
Supplier: MACHEREY-NAGEL
CHROMABOND® HR-P-AOX is a special PS/DVB phase for the SPE enrichment of AOX from water.
Expand 2 Items
Chiral HPLC columns, RESOLVOSIL
Supplier: MACHEREY-NAGEL
These columns contain a silica-based protein phase for HPLC enantiomer separation. The base material is NUCLEOSIL® silica, the chiral selector bovine serum albumin (BSA).
Expand 2 Items
SPE columns, CHROMABOND® PCA
Supplier: MACHEREY-NAGEL
CHROMABOND® PCA is a propylcarboxylic acid modified silica cation exchanger for SPE.
Expand 3 Items
SPE columns, CHROMABOND® HILIC
Supplier: MACHEREY-NAGEL
CHROMABOND® HILIC is an ammonium – sulfonic acid modified silica phase for SPE.
Expand 2 Items
SPE columns, CHROMABOND® SB
Supplier: MACHEREY-NAGEL
CHROMABOND® SB is a quaternary ammonium modified silica anion exchanger (SAX) for SPE.
Expand 9 Items
HPLC columns, NUCLEODUR® CN/CN-RP
Supplier: MACHEREY-NAGEL
NUCLEODUR® CN and CN-RP are cyano (nitrile) modified silica phases for HPLC.
Expand 20 Items
HPLC columns, PAH analysis, NUCLEOSIL® C18 PAH
Supplier: MACHEREY-NAGEL
Special octadecyl modified silica phase for HPLC analysis of PAHs.
Expand 8 Items
HPLC columns, NUCLEODUR® C4 ec
Supplier: MACHEREY-NAGEL
NUCLEODUR® C4 ec is a medium density monomeric butyl modified silica phase for HPLC.
Expand 18 Items
HPLC columns, NUCLEOSHELL® RP 18plus
Supplier: MACHEREY-NAGEL
NUCLEOSHELL® RP 18plus based on core-shell particle technology for fast and efficient HPLC.
Expand 32 Items
HPLC columns, NUCLEOSIL® C18 Nautilus
Supplier: MACHEREY-NAGEL
NUCLEOSIL® C18 Nautilus is an endcapped octadecyl modified silica phase with an embedded polar group, using for HPLC.
Expand 10 Items
HPLC columns, NUCLEODUR® C18 ec
Supplier: MACHEREY-NAGEL
NUCLEODUR® C18 ec is a medium density monomeric octadecyl modified silica phase for HPLC.
Expand 74 Items
HPLC columns, Cogent TYPE-C Silica™
Supplier: MICROSOLV
Cogent TYPE-C Silica™ is HPLC grade silica with a silica hydride surface. Their unique stationary phase will adsorb and desorb solvents commonly used in mobile phases very differently from ordinary silica resulting in excellent benefits to the chromatographer. Excellent for normal phase chromatography and solvent drying is not needed.
Expand 32 Items
Reversed phase HPLC columns, PRP-1
Supplier: HAMILTON BONADUZ
PRP-1 polymeric HPLC columns are designed for broad ranging uses, similar to C8 or C18 HPLC materials. They combine the best characteristics of silica-based and polymeric columns resulting in highly inert and long-lasting columns. These columns are ideal for applications that require a high degree of column to column and batch to batch consistency (quality assurance, clinical trials). Unlike C8 or C18 columns, PRP-1 has no stationary phase coating. Since there is no stationary phase to hydrolyse, the column maintains its performance characteristics longer than many C8 or C18 columns.
Expand 42 Items
SPE columns, PFAS, CHROMABOND
Supplier: MACHEREY-NAGEL
Special phase for SPE analysis. For enrichment of PFAS from water, textiles and sediments (contaminated soils). Polymeric combination phase with weak anion exchanger, highly porous, spherical particles.
Expand 2 Items
Chiral HPLC columns, NUCLEOSIL® CHIRAL
Supplier: MACHEREY-NAGEL
Silica based phases for HPLC enantiomer separation in which CHIRAL-1 seperation is based on ligand exchange and CHIRAL-2 or CHIRAL-3 on charge-transfer and further interactions as well as on steric effects.