2249 Results for: "Trajan Scientific and Medical"
SGE HT8-PCB GC Capillary Columns
Supplier: Trajan Scientific and Medical
The SGE HT8-PCB GC Capillary Column provides a great low-polarity option for GC analyses. Recommended for PCB congener analyses, nitro-substituted aromatics, polynuclear aromatic hydrocarbons, pesticides/herbicides.
Expand 2 Items
Gas filter connecting units
Supplier: Trajan Scientific and Medical
A connecting unit with inlet and outlet connectors for the gas lines.
Expand 8 Items
Replacement needles for syringes RTC/RSH
Supplier: Trajan Scientific and Medical
Needle, Replacement needle for 25 - 500 µl syringes, Gauge: 23, Length: 50 mm, Ø ext.: 0,63 mm, Type of tip: Side hole/dome
Expand 5 Items
Replacement plungers
Supplier: Trajan Scientific and Medical
Replacement plunger, P250R-AGILENT-MEPS-GT 250 µl
Expand 43 Items
Replacement needles for syringes for CTC analytics systems
Supplier: Trajan Scientific and Medical
Needle, Plunger-in-needle kit, Gauge: 23, Length: 50 mm, Ø ext.: 0,63 mm, Type of tip: Cone
Expand 4 Items
PEEKsil™ Tubing
Supplier: Trajan Scientific and Medical
Chromatography tubing, PEEK, PEEKsil™ capillary tubing for HPLC, LC/MS applications, Ø int.: 0,05 mm, Ø ext.: 0,79 mm, Colour: Beige, Length: 150 mm
Expand 75 Items
Advanced Green 3 Low-Bleed GC Septas
Supplier: Trajan Scientific and Medical
Advanced Green 3 low-bleed GC septa is a premium septa for autosamplers in all critical analyses.
Expand 15 Items
PTFE GC Ferrules
Supplier: Trajan Scientific and Medical
These GC ferrules are made from 100% PTFE. They are soft, completely inert, and have very low friction.
Expand 22 Items
CRS Puresep T GC Septa
Supplier: Trajan Scientific and Medical
Reliabily against the carrier gas pressure in the inlet. Capable of being pierced and resealing time after time without pieces of the septa being deposited in the GC inlet system. Does not contaminate or bleed material into the chromatographic system.
Expand 5 Items
Diamond MS syringes
Supplier: Trajan Scientific and Medical
Diamond MS syringes are designed to improve the sensitivity of your MS analysis.
Expand 17 Items
Syringes for HPLC autosamplers, Waters instruments
Supplier: Trajan Scientific and Medical
Syringe, chromatography, HPLC, With PTFE-tipped plunger, 1/4-28 UNF front thread, 250D-WISP, Volume: 250 µl, For: Waters instruments, Pk: 1
Expand 2 Items
Spanner, open end, SGE
Supplier: Trajan Scientific and Medical
Spanner sizes and uses: 3/16" for use with mini unions, 1/4" for use with 1/16" nuts, 5/16" for use with micro control valves.
Expand 1 Items
EasyLOK fittings
Supplier: Trajan Scientific and Medical
These fittings are composed of a knurled stainless steel nut and a double ended PEEK™ ferrule.
Expand 2 Items
Spare plungers for Luer tip syringes
Supplier: Trajan Scientific and Medical
P1MD-GT, plunger, 1 ml
Expand 7 Items
Capillary electrophoresis tubing
Supplier: Trajan Scientific and Medical
Manufactured from precision bore tubing.
Expand 6 Items
Needles for syringes with valves
Supplier: Trajan Scientific and Medical
Needle, Valve needle for syringes with valves, Gauge: 23, Length: 50 mm, Ø ext.: 0,63 mm, Type of tip: Side hole/dome
Expand 2 Items
Accessories or tubing cutter, Terry-Tool
Supplier: Trajan Scientific and Medical
Replacement cutting wheels
Expand 1 Items
Syringes, Cavro
Supplier: Trajan Scientific and Medical
These cavro syringes are a type of instrument syringes used in chromatography.
Expand 1 Items
SGE BPX90 GC Capillary Columns
Supplier: Trajan Scientific and Medical
The SGE BPX90 GC capillary column provides a great polar option for GC analyses. Recommended for fast separation of fragrances, aromatics, petrochemical, pesticides, PCBs, isomers of Fatty Acid Methyl Esters (FAMEs).
Expand 5 Items
SGE BPX70 GC Capillary Columns
Supplier: Trajan Scientific and Medical
The SGE BPX70 GC capillary column provides a great polar option for GC analyses. Recommended for fatty acid methyl esters (FAMEs), carbohydrates, pharmaceuticals, GC-MS applications.
Expand 16 Items
CRS ONE O-Rings for Inlet Liner Seals
Supplier: Trajan Scientific and Medical
The o-ring prevents gas leaks and maintains a uniform flow path through the inlet, where even small leaks can cause sample loss - affecting accuracy and reproducibility of results.
Expand 3 Items
Pure-Pass™ Well Plates, 96- and 384-Wells
Supplier: Trajan Scientific and Medical
These as-molded, untreated plates are manufactured from a high purity polypropylene copolymer, making them some of the cleanest uncoated plastic plates.
Expand 12 Items
Vespel® Graphite GC Ferrules
Supplier: Trajan Scientific and Medical
Vespel/graphite GC ferrules are made from quality polyimide/graphite blend. They seal with minimal torque and can be reused and repositioned along capillary columns if not over compressed in the fitting. Due to slight shrinking at high temperatures, they must be retightened after initial temperature cycles to avoid leaks.
Expand 57 Items
CRS Advanced Filter System Gas Purifiers
Supplier: Trajan Scientific and Medical
A high-capacity gas purifying system that can remove a combination of oxygen, moisture and hydrocarbons, (greater than C4) from inert gases and hydrogen.
Expand 11 Items
CRS SPure™ H₂O/HC Filters
Supplier: Trajan Scientific and Medical
The SPure H₂O/HC Filter removes moisture, oil, dust, and hydrocarbons (C5 and heavier) from dry air and inert gases.
Expand 48 Items
CRS ZPure™ O₂/H₂O Gas Filters
Supplier: Trajan Scientific and Medical
ZPure™ O₂/H₂O gas filters removes oxygen and water from inert gases, He, Ar, N₂ and H₂, making it ideal for use with GC and GC/MS carrier gas lines. It differs from the Zpure dual filter in that it is completely non-hazardous and is recommended for any application requiring ultra-pure gas, free from oxygen and water.
Expand 42 Items
CRS ZPure™ H₂O HSMI Indicating Filters
Supplier: Trajan Scientific and Medical
The ZPure™ H₂O 'High Sensitivity Moisture Indicating' Filter is used for applications requiring high efficiency moisture removal. The high sensitivity indicator signals breakthrough at 1 ppm water and changes from blue to brown.
Expand 10 Items
Mitra® Microsamplers, Clamshell Format
Supplier: Trajan Scientific and Medical
The Mitra® is a small, portable device with an absorbent VAMS® tip that is designed to collect a tiny, precise volume of blood. The Mitra device is used for capillary sampling from a fingertip or other site on the body. This approach is less invasive than venipuncture, doesn't require expensive cold shipping, and requires only a small blood volume for dried-matrix analysis.
Expand 2 Items
SGE OptChem™ Straight Inlet Liners
Supplier: Trajan Scientific and Medical
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner. Choosing the right inlet liner and injection parameters can increase peak areas and reduce detection limits by up to 300%.
Expand 6 Items
SGE OptChem™ FocusLiners Inlet Liners
Supplier: Trajan Scientific and Medical
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner. Choosing the right inlet liner and injection parameters can increase peak areas and reduce detection limits by up to 300%.