"Mass Spectrometry"
HPTLC and TLC plates, silica gel 60, MS-grade
Supplier: Merck
Coupling TLC plates to mass spectrometry is a new field of high interest, which will contribute strongly to the progress of planar chromatography. The MS-grade plates are much cleaner than standard TLC/HPTLC plates providing higher sensitivity and reduced background signals. This allows trace analysis with mass spectrometry detection in lower nanogram range.
Expand 4 Items
Supelco® TraceCERT® Organic Reference Standard, Monolinuron
Supplier: Merck
Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).
Expand 1 Items
Organic reference standard, Zearalenone-¹³C₁₈ solution, analytical standard, Supelco®
Supplier: Merck
Zearalenone-¹³C₁₈ may be used as an analytical standard for the determination of zearalenone in animal feed by liquid chromatography combined with tandem mass spectrometry (LC-MS/MS).
Expand 1 Items
High Select™ HSA/immunoglobulin depletion resin
Supplier: Thermo Fisher Scientific
Thermo Scientific™ High Select HSA/Immunoglobulin Depletion Resin decreases the albumin and antibody components that are abundant in human plasma samples, helping prepare the samples for mass spectrometry or 1D or 2D electrophoresis.
Expand 1 Items
2,3,4,5,6-Pentafluorobenzyl chloroformate 97%
Supplier: Apollo Scientific
Derivatisation agent for the analysis of amines, alcohols, and amino acids by Electron-Capture Negative Ion Chemical Ionisation-Mass Spectrometry.
Expand 3 Items
High Select™ top14 abundant protein depletion resin, Pierce™
Supplier: Thermo Fisher Scientific
Thermo Scientific™ High Select Top14 Abundant Protein Depletion Resin decreases the abundant protein and antibody components of human plasma samples, helping prepare the samples for mass spectrometry or 1D or 2D electrophoresis.
Expand 1 Items
Silver stain, FOCUS™ FASTsilver™
Supplier: G-Biosciences
FOCUS™ FASTsilver™ produces crystal clear backgrounds and maximal peptide recovery needed for critical analysis by mass spectrometry. Complete proteolytic digestion and recovery of peptides is required for optimal analysis, however silver ions in traditional silver staining kits inhibit proteolytic digestion. In addition, glutaraldehyde, a common sensitiser in silver stains, modifies peptide lysine residues preventing complete digestion and recovery.
Expand 2 Items
Replacement parts for mass spectrometry
Supplier: AGILENT HEWLETT PACKARD
Filter for solvent
Expand 29 Items
Organic reference standard, Melamine-13C3, analytical standard, VETRANAL™, Supelco®
Supplier: Merck
Melamine-¹³C₃ may be used as an analytical standard for the determination of melamine in milk powder samples by liquid chromatography-electrospray ionisation-isotope dilution mass spectrometry (LC-ESI-IDMS).
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Metrafenone
Supplier: Merck
Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).
Expand 1 Items
Pesticide reference standard, Ronidazole-d3, VETRANAL(TM), analytical standard, Supelco®
Supplier: Merck
Ronidazole-d₃ may be used internal standard in the determination of avermectins, benzimidazoles and nitroimidazoles residues in bovine muscle tissue using ultra-high performance liquid chromatography coupled with mass spectrometry (UHPLC/MS-MS).
Expand 1 Items
Organic reference standard, Leucocrystal Violet-d6, analytical standard, Supelco®
Supplier: Merck
Leucocrystal violet-d₆ might be used as an internal standard in the determination of triphenylmethane dyes in rainbow trout samples using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS).
Expand 1 Items
Organic reference standard, 2,3-Hexanedione, analytical standard, Supelco®
Supplier: Merck
2,3-Hexanedione can be used as an internal standard for the quantitative determination of methylglyoxal present in the tissues of Sprague-Dawley rats using electrospray ionization liquid chromatography coupled with mass spectrometry(ESI/LC/MS).
Expand 1 Items
Endoproteinase Glu-C protease, MS grade, Pierce™
Supplier: Thermo Fisher Scientific
Glu-C protease is a highly specific endoproteinase use to improve sequence coverage in mass spectrometry protein identification applications.
Expand 1 Items
Endoproteinase Asp-N protease, MS grade, Pierce™
Supplier: Thermo Fisher Scientific
Asp-N protease is a highly specific endoproteinase used to improve sequence coverage in mass spectrometry protein identification applications.
Expand 1 Items
Supelco® TraceCERT® Organic Reference Standard, Simazine
Supplier: Merck
Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).



