21 Results for: "ELWE LEHRGERAETEBAU KLINGENTHA"
Franck-hertz tries with
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Franck-Hertz's experiment is one of the best ways to show the quantum properties of atoms. The experiment verifies the excitation energy of the Hg atoms through collisions with free electrons. Franck-Hertz tubes consist of an oxide cathode, gallery anode and a collection electrode. The evacuated tube contains a drop of Hg. Before starting the measurements, the pipe must be heated to 200 °C, partly to increase the pressure of the Hg steam and partly to obtain a sufficient probability of collision. When the temperature in the tube has become constant, the cathode is heated and a direct voltage which can be varied in the range 0 to 50 V is connected between the cathode and the anode. When the counter voltage is set to about -1,5 V and the anode voltage increases slowly from 0 V, the electrons will soon reach speeds in the acceleration range of the tube so that an increasing part of the primary current reaches the collector electrode. As the velocity of the electron flux approaches the lowest excitation level of the Hg atoms (4,9 eV), the electrons of the Hg atoms are capable of leaving the atoms and thus losing some of their velocity. The collector current drops to a minimum value. The Hg atom then emits its 253,7 nm ultraviolet line and then returns to its normal energy level. As the acceleration voltage increases further, the current reaching the collector electrode will increase again. This process is repeated periodically many times.
Expand 1 Items
Sound sensor on rod
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Cone-shaped pressure chamber speaker with high power resistance. Used for general acoustic tests, eg together with resonator 765-0080. Connects to a tone generator with amplifier. Melt protection prevents damage during overload. Technical data.
Expand 1 Items
Wire beam tubes
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
For examination of the deflection of the electron beam in a magnetic field. Particularly suitable for determining e/m in a homogeneous magnetic field generated by Helmholtz coils. Spherical glass flask containing i.a. an electron gun with indirectly heated cathode and anode with holes. The glass flask is filled with neon of low pressure. The gas atoms are ionized by the electrons and are thus excited so that light can be emitted. Therefore, a visible luminous beam is formed along the path of the electrons.
Expand 1 Items
The charge of the electron, acc. busch
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
The exercise oscilloscope is placed at the Helmholtz coils so that its main axis coincides with the axis of the coils. A sawtooth-shaped voltage is applied to the deflection plates of the oscilloscope so that a smooth horizontal line appears on the screen. Let direct current pass through the coils at a preset anode voltage and adjust the intensity of the current so that the line is focused at one point. The specific charge e/m of the electron can be calculated from the measured values of the anode voltage and the current through the coil.
Expand 1 Items
Helmholtz coils
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Used e.g. to form homogeneous magnetic fields. Two identical coils placed in parallel by means of three fastening devices. The coils can be connected in series or in parallel. To determine e/m, the wire beam tube is placed between the Helmholtz coils in such a way that the visible beam is perpendicular to the homogeneous magnetic field. The generated magnetic field can be measured with a magnetic field meter with hall elements. Specifications.
Expand 1 Items
Motor, 12 V DC, with iron-free rotor
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Motor with rotor that lacks iron and thereby has a very low moment of inertia, which in turn enables fast start and stop or change of direction of rotation. The time from start to maximum speed (3000 rpm) is only 11 ms. Can be used for experiments with mechanical oscillations. The motor is most conveniently operated with a function generator.
Expand 1 Items
Vekt mikro 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Vekt mikro 1 * 1 Items
Expand 1 Items
FRANCK-HERTZ RÖR MED ENDAST HG RÖR 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
FRANCK-HERTZ RÖR MED ENDAST HG RÖR 1 * 1 Items
Expand 1 Items
TRÅDSTRÅLERØR U/STATIV 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
TRÅDSTRÅLERØR U/STATIV 1 * 1 Items
Expand 1 Items
FRANCK HERTZ STYRENHED 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
FRANCK HERTZ STYRENHED 1 * 1 Items
Expand 1 Items
ELEKTROSTATISK VOLTMETER 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
ELEKTROSTATISK VOLTMETER 1 * 1 Items
Expand 1 Items
KATODSTRÅLE RÖR ENL. BRAUNSCH 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
KATODSTRÅLE RÖR ENL. BRAUNSCH 1 * 1 Items
Expand 1 Items
FRANCK HERTZ SKRMET KABEL 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
FRANCK HERTZ SKRMET KABEL 1 * 1 Items
Expand 1 Items
HÅNDLEDNING T/195800-26 1 * 1 Each
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
HÅNDLEDNING T/195800-26 1 * 1 Each
Expand 1 Items
FRANCK HERTZ SKÆRMET KABEL 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
FRANCK HERTZ SKÆRMET KABEL 1 * 1 Items
Expand 1 Items
ELEKTRO T/BSTS 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
ELEKTRO T/BSTS 1 * 1 Items
Expand 1 Items
ELEKTROFELTMETER 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
ELEKTROFELTMETER 1 * 1 Items
Expand 1 Items
FRANCK HERTZ TERMOMETER 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
FRANCK HERTZ TERMOMETER 1 * 1 Items
Expand 1 Items
EXPERIMENTHÅNDLEDNING 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
EXPERIMENTHÅNDLEDNING 1 * 1 Items
Expand 1 Items
Metallofon, 12 toner 1 * 1 Items
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
Metallofon, 12 toner 1 * 1 Items
Expand 1 Items
MIKROBØLGE 1 * 1 Each
Supplier: ELWE LEHRGERAETEBAU KLINGENTHA
MIKROBØLGE 1 * 1 Each