Sentry guard cartridges, XBridge™
Supplier: WATERS
XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent.
Expand 5 Items
Solid phase extraction cartridges, Sep-Pak® Vac
Supplier: WATERS
These cartridges deliver the option of minimum sample preparation. Consists of moulded, high purity PP syringe-barrel bodies with two PE frits to contain the packing material.
Expand 6 Items
Analytical HPLC columns, Symmetry® C18
Supplier: WATERS
Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.
Expand 13 Items
Gel permeation chromatography columns, Styragel® HR
Supplier: WATERS
Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.
Expand 6 Items
Analytical HPLC columns, XSelect™ CSH C18
Supplier: WATERS
XSelect™ CSH C18 is a general purpose column that provides alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps to overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed and slow mobile-phase re-equilibration.
Expand 2 Items
Analytical HPLC columns, Nova-Pak® C18
Supplier: WATERS
Nova-Pak® C18 columns are general purpose, silica based, reversed phase C18 columns that are based on 4 µm particle technology.
Expand 5 Items
Solid phase extraction cartridges, Sep-Pak® Classic
Supplier: WATERS
Silica-based bonded phase with strong hydrophobicity used to adsorb analytes of even weak hydrophobicity from aqueous solutions.
Expand 2 Items
Analytical HPLC columns, Resolve® C18
Supplier: WATERS
The combination of hydrophobic and silanophilic mechanisms make Resolve® C18 packings highly retentive for polar and non-polar compounds. Resolve® C18 packages are commonly used for agricultural, industrial, chemical and pharmaceutical applications where very retentive surfaces are needed to adsorb polar compounds.
Expand 1 Items
Screw neck vials
Supplier: WATERS
Chromatography vial, Screw neck, external thread, 1,00 ml, Glass, Clear, Ø×H: 12×32 mm, Non sterile, Cap included: Yes, Septum: PTFE/silicone, pre-slit
Expand 16 Items
Solid phase extraction cartridges, Oasis® HLB
Supplier: WATERS
Oasis® HLB cartridges contain the Oasis® HLB sorbent, which is a universal polymeric reversed phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol.
Expand 3 Items
Analytical HPLC columns, XBridge™ BEH C8
Supplier: WATERS
The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.
Expand 2 Items
Caps for screw neck vials
Supplier: WATERS
Dark blue PE screw cap with bonded slit septum for 12×32 mm vials.
Expand 1 Items
Analytical HPLC columns, SymmetryShield™ RP18
Supplier: WATERS
SymmetryShield™ columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry® C18 ligand.
Expand 7 Items
Glycan BEH amide columns, ACQUITY UPLC™
Supplier: WATERS
The ACQUITY UPLC BEH glycan separation technology column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.
Expand 3 Items
UPLC columns, ACQUITY UPLC™ BEH C18
Supplier: WATERS
These columns are suitable for a diverse range of analytes. With mobile phase (pH 1 to 12) and temperature (80 °C) compatibility, this trifunctionally-bonded alkyl column is a universal method development tool that can impact the retention, selectivity and sensitivity of ionisable compounds (with mobile phase pH) while delivering low- and high-pH stability for all analyte types.
Expand 5 Items
Gel permeation chromatography clean-up columns, Envirogel™
Supplier: WATERS
The Envirogel™ High-Resolution GPC cleanup columns are specifically designed to remove low volatility, high molecular weight interferences such as lipids and natural resins from environmental samples as specified in EPA method 3640A.
Expand 1 Items
Columns, ACQUITY UPLC™ HSS T3
Supplier: WATERS
An universal, silica based bonded phase with ACQUITY HSS T3 sorbents which is used for the separations for polar and non-polar compounds. It is compatibility with 100% of aqueous mobile phase. It exhibit ultra-low MS bleed, scalable and transferable to HPLC separations.
Expand 1 Items
Analytical HPLC columns, XBridge™ BEH Shield RP18
Supplier: WATERS
XBridge™ BEH Shield RP18 columns complement the XBridge™ BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Expand 3 Items
Solid phase extraction cartridges, Oasis® WAX
Supplier: WATERS
These Oasis® WAX cartridges contain the WAX sorbent, which is a polymeric reversed phase, weak anion exchange mixed mode sorbent that has been optimised for fast, simple, and highly selective sample preparation of strong acidic compounds.
Expand 1 Items
Analytical HPLC columns, XTerra® Phenyl
Supplier: WATERS
XTerra® Phenyl columns are hybrid-based, reversed phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 1 Items
SPE cartridge, Sep-Pak®
Supplier: WATERS
Specially designed for analysing formaldehyde, other aldehydes and ketones in air.
Expand 1 Items
Analytical HPLC columns, XTerra® MS C18
Supplier: WATERS
XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 9 Items
Analytical HPLC columns, Symmetry® C8
Supplier: WATERS
Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.
Expand 5 Items
Reversed phase HPLC columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 5 Items
Columns, ACQUITY UPLC™ CSH C18
Supplier: WATERS
ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.
Expand 3 Items
Analytical HPLC columns, µBondapak® Phenyl
Supplier: WATERS
Column type: HPLC column, µBondapak®, Phenyl, Ø int.: 3,90 mm, Length: 300 mm, Pore size: 125 Å, Particle size: 10 µm
Expand 1 Items
Analytical HPLC columns, XTerra® RP8
Supplier: WATERS
XTerra® RP8 columns are general purpose, hybrid-based, reversed phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 1 Items
Analytical HPLC columns, SunFire™ C18
Supplier: WATERS
SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.
Expand 10 Items
Reversed phase HPLC columns, Atlantis® Silica HILIC
Supplier: WATERS
Atlantis HILIC silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography.
Expand 2 Items
Analytical HPLC columns, XTerra® MS C8
Supplier: WATERS
XTerra® MS C8 columns are general purpose, hybrid-based, reversed phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.