Solid phase extraction cartridges, Bond Elut™ CH
Supplier: VARIAN
Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ Certify
Supplier: VARIAN
The Bond Elut™ Certify extraction cartridge utilises a packed bed consisting of a special, non-polar C8 sorbent and a strong cation exchanger (SCX). Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but it is also very effective for extraction of a wide range of compounds from a diverse range of aqueous matrices.
Expand 33 Items
Bond elut C18 OH plates
Supplier: VARIAN
Bond Elut C18 OH is unendcapped, offering tightly controlled silanol activity to support fractionation. C18 OH delivers enhanced retention of polar analytes.
Expand 2 Items
Solid phase extraction cartridges, Bond Elut™ PH
Supplier: VARIAN
Bond Elut™ PH is a non-polar bonded silica material which exhibits a different selectivity to alkyl or aliphatic functionalised phases such as C8 or cyclohexyl. The electron density present in the aromatic ring affords an enhancement in the retention of conjugated or aromatic ring-containing analytes due to desirable pi-pi interactions.
Expand 11 Items
PLOT columns, CP-PoraPLOT Q and CP-PoraPLOT Q-HT
Supplier: VARIAN
CP-PoraPLOT Q is recommended for column switching systems that analyze polar and apolar volatile compounds.
Expand 17 Items
HPLC columns, VariTide RPC
Supplier: VARIAN
VariTide RPC column is designed for use across the pH range, making it suitable for the analysis and purification of acid or basic and hydrophilic or hydrophobic peptides, using acid, neutral and basic eluents.
Expand 5 Items
Tubing
Supplier: VARIAN
Copper and stainless steel tubing for gas chromatography (GC) applications.
Expand 6 Items
Resin, PL Cl-Trt-Cl, StratoSpheres™
Supplier: VARIAN
PL Cl-Trt-Cl supports peptide synthesis using the Fmoc approach. This resin can be used for the synthesis of a wide range of organic acids, and has also been used for the synthesis of amines, phenols and other alcohols.
Expand 2 Items
Resin, PL-Wang, StratoSpheres™
Supplier: VARIAN
PL-Wang is a 4-alkoxybenzylalcohol functionalised polystyrene, prepared from copolymerised PL-CMS, for solid phase peptide synthesis using Fmoc protection strategies and is cleaved using ~ 95% TFA. Particularly useful for solid phase synthesis of small molecules which have a carboxylic acid functional group.
Expand 4 Items
HPLC columns, Pursuit™ UPS2,4
Supplier: VARIAN
Pursuit™ UPS 2,4 columns couple highly efficient, fast separations with superior ease-of-use. They are designed for solvent applications and samples where lifetime and back pressure are important concerns.
Expand 9 Items
Well plate tubes for Bond Elut C18 EWP plates
Supplier: VARIAN
VersaPlate well plate tubes, C18 EWP, 300 mg
Expand 1 Items
Merlin Microseal
Supplier: VARIAN
The Merlin Microseal is available in standard and high pressure kits.
Expand 1 Items
Capillary columns, select permanent gases
Supplier: VARIAN
Select Permanent Gases/CO₂ is a set of two parallel columns that combines CP-Molsieve 5 Å for permanent gas analysis and CP-PoraBOND Q for CO₂ analysis.
Expand 3 Items
Tubing kit for aromatic organic solvents
Supplier: VARIAN
The ICP-OES tubing kit for aromatic organic solvents includes:
Expand 4 Items
Capillary columns, Rapid-MS
Supplier: VARIAN
Rapid-MS columns reduce analysis duration by 3 to 5 times for temperature programmed, and up to 10 times for isothermal runs.
Expand 4 Items
Platform rocker, tapped density tester
Supplier: VARIAN
Shaker, Platform, 250 ml, 3 mm drop, USP or ASTM
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ Diol
Supplier: VARIAN
Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.
Expand 6 Items
Capillary columns, volatile, mineral oil
Supplier: VARIAN
Select mineral oil provides the shortest analysis time is required with a stabilized, non-polar bonded phase specifically for fast mineral oil analysis.
Expand 4 Items
Capillary columns, CP-Select 624 CB
Supplier: VARIAN
The CP-Select 624 CB is a highly reproducible version of the popular 624 phase and has 2-3 times lower bleed than conventional columns.
Expand 9 Items
Specialty solid phase extraction cartridges, Bond Elut™ Carbon/NH₂
Supplier: VARIAN
These specialty solid phase extraction cartridges provide higher retention of small organics, including those that are too polar to retain on C18 or polymeric SPE.
Expand 7 Items
Cross-linked and bonded μSIL capillaries
Supplier: VARIAN
A series of coated capillaries specifically designed for CE, which are prepared by cross-linking and bonding a novel, proprietary fluorocarbon (FC) polymer. μSIL-FC capillaries are chemically inert, hydrophobic, and stable from pH 2,5 to 10.
Expand 1 Items
Accessories for 240-MS GC/MS ion trap mass spectrometer
Supplier: VARIAN
CI gas inlet, manifold
Expand 1 Items
HPLC columns, Polaris™ amide C18
Supplier: VARIAN
Polaris™ amide C18 has the greatest polarity of the Polaris™ C18 family. The amide polar groups offer a different selectivity from either the C18-A or C18-ether phases. The surface has been covalently modified with alkyl amide groups and endcapped.
Expand 32 Items
HPLC columns, Polaris™ NH₂
Supplier: VARIAN
Polaris™ NH₂ is an aminopropylsilane-covered silica that can be used in either reversed or normal phase conditions. Exhibit higher efficiencies for carbohydrate analysis than ionic gel-based columns
Expand 31 Items
Capillary columns, VF-1301ms
Supplier: VARIAN
VF-1301ms ultra-low-bleed thin film columns have a similar selectivity to VF-624ms and are suitable for the analysis of semivolatile organic solvents, as well as PCBs and pesticides.
Expand 5 Items
Cuvettes for fluorescence
measurements
Supplier: VARIAN
These cuvettes are designed for use with Cary Eclipse fluorescence spectrophotometer.