"Restek"
Bio-Safe column system
Supplier: Restek
Bio-Safe columns are biocompatible and precision-machined from virgin PEEK.
Expand 1 Items
Antifoam agent for purge-and-trap samples
Supplier: Restek
Foam generated as purge gas passes through a sample can enter the analytical trap and possibly the GC column. This silica-containing antifoam agent is effective over a wide pH range and will not conflict with chromatography of target analytes.
Expand 1 Items
Oxy setup blend (29 components)
Supplier: Restek
ASTM Method D6730-01 is specifically designed for the determination of the individual hydrocarbons present in spark ignition fuels, as well as fuel blends containing oxygenates such as methyl tert-butyl ether, ethyl tert-butyl ether, tert-butanol, ethanol, etc.
Expand 1 Items
High-capacity oxygen trap
Supplier: Restek
These high-capacity oxygen trap removes up to 135 ml of oxygen or 2 g of water.
Expand 2 Items
Direct replacement reducing nut
Supplier: Restek
Direct replacement reducing nut, high-quality stainless steel, for Agilent 5890/6850/6890 GC's
Expand 1 Items
PCB congener mix, method 8082A (19 components)
Supplier: Restek
Contains 19 components, those are 2-chlorobiphenyl , 2,3-dichlorobiphenyl , 2,2',5-trichlorobiphenyl , 2,4',5-trichlorobiphenyl, 2,2',3,5'-tetrachlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl, 2,3',4,4'-tetrachlorobiphenyl, 2,2',3,4,5'-pentachlorobiphenyl, 2,2',4,5,5'-pentachlorobiphenyl, 2,3,3',4',6-pentachlorobiphenyl, 2,2',3,4,4',5'-hexachlorobiphenyl, 2,2',3,4,5,5'-hexachlorobiphenyl, 2,2',3,5,5',6-hexachlorobiphenyl, 2,2',4,4',5,5'-hexachlorobiphenyl, 2,2',3,3',4,4',5-heptachlorobiphenyl, 2,2',3,4,4',5,5'-heptachlorobiphenyl, 2,2',3,4,4',5',6-heptachlorobiphenyl, 2,2',3,4',5,5',6-heptachlorobiphenyl and 2,2',3,3',4,4',5,5',6-nonachlorobiphenyl.
Expand 1 Items
Capillary columns, Rtx®-Dioxin2 (fused silica)
Supplier: Restek
These capillary columns are isomer specificity for 2,3,7,8-TCDD and 2,3,7,8-TCDF achieved with one GC column. Unique selectivity for toxic dioxin and furan congeners which allows to use as a confirmation GC column.
Expand 2 Items
WA VPH standard (15 components)
Supplier: Restek
WA VPH standard contains (C5) n-pentane, (C6) n-hexane, (C8) n-octane, (C10) n-decane, (C12) n-dodecane
benzene, ethylbenzene, 1-methylnaphthalene, methyl tert-butyl ether (MTBE), naphthalene, toluene, 1,2,3-trimethylbenzene, m-xylene, o-xylene, p-xylene.
Expand 1 Items
N,O-Bis(trimethylsilyl)trifluoroacetamide with 1% trimethylchlorosilane
Supplier: Restek
Silylation derivatization reagent.
Expand 2 Items
European pharmacopoeia/ICH Class 2 mix C (6 components)
Supplier: Restek
The european pharmacopoeia/ICH Class 2 mix C consists of six components, they are 2-ethoxyethanol (160 μg/ml), ethylene glycol (620 μg/ml), formamide (220 μg/ml), 2-methoxyethanol (methyl cellosolve) (50 μg/ml), n-methylpyrrolidone (4,840 μg/m)l and sulpholane (160 μg/m)l.
Expand 1 Items
PEEK tubing elbows
Supplier: Restek
Tubing elbows are ideal for routing 1,6 mm PEEK tubing that snap the tubing into the elbow. Its prevent pinching of PEEK tubing, which can cause high pressure.
Expand 2 Items
Septa, Merlin Microseal™
Supplier: Restek
Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner. The septum uses a 23-gauge (0,63 mm, 0,025”) needle or probe with a blunt, truncated conical tip. Since the syringe plunger end details are determined by manual or autosampler compatibility. The advantages of the septum include elimination of septum coring, longer life, consistent and low needle insertion force.
Expand 7 Items
ASTM D6042-96 calibration mix (7 components)
Supplier: Restek
This mixture contains the common antioxidants and slips listed in ASTM D6042-96, along with BHT.



