These ion-selective half-cells (exception: Sodium-sensitive electrode) consist of two elements: a universal shaft and an ion-specific membrane module.
- Available as half-cells (require external reference electrode) or as electrodes with built-in reference
- Each ion-selective electrode (ISE) and each membrane module is tested wet-chemically
- Each ISE is issued with its own serial number and quality certificate
- Electrodes are filled with electrolyte and ready for use
- Membrane kit comes with an identification ring (ID ring) and an adapter sleeve which will fit any METTLER TOLEDO titration stand
This module may be exchanged allowing users to measure the ion of their choice. They just need to order the membrane kit specific for that ion, mount the new module onto the shaft of the ISE half-cell, and they have a new ISE.
22 Options Available Below
Product Details & Documents
These ion-selective half-cells (exception: Sodium-sensitive electrode) consist of two elements: a universal shaft and an ion-specific membrane module.
- Available as half-cells (require external reference electrode) or as electrodes with built-in reference
- Each ion-selective electrode (ISE) and each membrane module is tested wet-chemically
- Each ISE is issued with its own serial number and quality certificate
- Electrodes are filled with electrolyte and ready for use
- Membrane kit comes with an identification ring (ID ring) and an adapter sleeve which will fit any METTLER TOLEDO titration stand
This module may be exchanged allowing users to measure the ion of their choice. They just need to order the membrane kit specific for that ion, mount the new module onto the shaft of the ISE half-cell, and they have a new ISE.
Documents
Mettler InLab® Sensors
Product Literature
Product Family Options
Electrodes
Product Information
- ConcentrationpHTemp.TypeMaterialElectrolyteConnectionØ×LForAvailabilityPrice
- 662-2803Ion selective half-cell electrode for Na+, solid state membraneIon selective half-cell electrode for Na+, solid state membrane1,0 - 1,0E-07 mol/l8 - 110...+80 °CDX223-Na+Glass-S7Log in for availability1 * 1 items530,00 €Specifications:
More
Specifications
Cat. No.662-2803 - METT51107672Ion selective half-cell electrode for Cd²⁺, polymer membraneIon selective half-cell electrode for Cd²⁺, polymer membrane10⁰ - 1×10⁻⁶ mol/l2 - 80...+50 °CDX312-Cd²⁺POM/PVC1 mol/l KNO₃S7Log in for availability1 * 1 items1 460,00 €Specifications:
More
Specifications
Cat. No.METT51107672 - METT51107673Ion selective half-cell electrode for Li⁺, polymer membraneIon selective half-cell electrode for Li⁺, polymer membrane10⁰ - 1×10⁻⁶ mol/l2 - 90...+50 °CDX207-Li⁺POM/PVC3 mol/l KClS7Log in for availability1 * 1 items1 440,00 €Specifications:
More
Specifications
Cat. No.METT51107673 - METT51107674Ion selective half-cell electrode for Ba²⁺, polymer membraneIon selective half-cell electrode for Ba²⁺, polymer membrane10⁰ - 4×10⁻⁷ mol/l2 - 120...+50 °CDX337-Ba²⁺POM/PVC3 mol/l KClS7Log in for availability1 * 1 items1 440,00 €Specifications:
More
Specifications
Cat. No.METT51107674 - METT51107675Ion selective half-cell electrode for S²⁻/Ag⁺, solid state membraneIon selective half-cell electrode for S²⁻/Ag⁺, solid state membrane10⁰ - 1×10⁻⁸ mol/l4 - 130...+80 °CDX232-S²⁻POM1 mol/l KNO₃S7Log in for availability1 * 1 items1 360,00 €Specifications:
More
Specifications
Cat. No.METT51107675 - METT51107676Ion selective half-cell electrode for BF₄⁻, polymer membraneIon selective half-cell electrode for BF₄⁻, polymer membrane10⁰ - 3×10⁻⁷ mol/l2 - 120...+50 °CDX287-BF₄⁻POM/PVC2 mol/l MgSO₄S7Log in for availability1 * 1 items1 450,00 €Specifications:
More
Specifications
Cat. No.METT51107676 - METT51107678Ion selective half-cell electrode for Cu²⁺, solid state membraneIon selective half-cell electrode for Cu²⁺, solid state membrane10⁰ - 5×10⁻⁷ mol/l2 - 80...+80 °CDX264-Cu²⁺POM1 mol/l KNO₃S7Log in for availability1 * 1 items1 420,00 €Specifications:
More
Specifications
Cat. No.METT51107678 - METT51107680Ion selective half-cell electrode for I⁻, solid state membraneIon selective half-cell electrode for I⁻, solid state membrane10⁰ - 2×10⁻⁸ mol/l1 - 130...+80 °CDX327-I⁻POM1 mol/l KNO₃S7Log in for availability1 * 1 items1 330,00 €Specifications:
More
Specifications
Cat. No.METT51107680 - METT51107681Ion selective half-cell electrode for CN⁻, solid state membraneIon selective half-cell electrode for CN⁻, solid state membrane10⁰ - 2×10⁻⁶ mol/l4 - 130...+80 °CDX226-CN⁻POM1 mol/l KNO₃S7Log in for availability1 * 1 items1 340,00 €Specifications:
More
Specifications
Cat. No.METT51107681 - METT51107870Ion selective half-cell electrode for SCN⁻, solid state membraneIon selective half-cell electrode for SCN⁻, solid state membrane10⁰ - 2×10⁻⁶ mol/l2 - 100...+80 °CDX258-SCN⁻POM1 mol/l KNO₃S7Log in for availability1 * 1 items1 330,00 €Specifications:
More
Specifications
Cat. No.METT51107870 - METT51107873Ion selective half-cell electrode for Pb²⁺, polymer membraneIon selective half-cell electrode for Pb²⁺, polymer membrane10⁰ - 3×10⁻⁶ mol/l2 - 80...+50 °CDX407-Pb²⁺POM/PVC1 mol/l KNO₃S7Log in for availability1 * 1 items1 350,00 €Specifications:
More
Specifications
Cat. No.METT51107873
Membrane kits
Product Information
- ConcentrationpHTemp.TypeMaterialElectrolyteConnectionØ×LForAvailabilityPrice
- METT51107686Membrane kit for DX312-Cd²⁺Specifications:
More
Specifications
Cat. No.METT51107686 - METT51107687Membrane kit for DX207-Li⁺Specifications:
More
Specifications
Cat. No.METT51107687 - METT51107688Membrane kit for DX337-Ba²⁺Specifications:
More
Specifications
Cat. No.METT51107688 - METT51107689Membrane kit for DX232-S²⁻Specifications:
More
Specifications
Cat. No.METT51107689 - METT51107690Membrane kit for DX287-BF₄⁻Specifications:
More
Specifications
Cat. No.METT51107690 - METT51107692Membrane kit for DX264-Cu²⁺Specifications:
More
Specifications
Cat. No.METT51107692 - METT51107694Membrane kit for DX327-I⁻Specifications:
More
Specifications
Cat. No.METT51107694 - METT51107695Membrane kit for DX226-CN⁻Specifications:
More
Specifications
Cat. No.METT51107695 - METT51107871Membrane kit for DX258-SCN⁻Specifications:
More
Specifications
Cat. No.METT51107871 - METT51107874Membrane kit for DX407-Pb²⁺Specifications:
More
Specifications
Cat. No.METT51107874
Reference electrode
Product Information
- ConcentrationpHTemp.TypeMaterialElectrolyteConnectionØ×LForAvailabilityPrice
- METT51089935Glass reference electrode, DX200Glass reference electrode, DX2000 - 140...+80 °CVariable12×172,5 mmISE/pH measurements, aqueous and non-aqueous mediaLog in for availability1 * 1 items645,00 €Specifications:
More
Specifications
Cat. No.METT51089935