Specifications
- Output:PNP-NO/NC 150 mA (20 °C)/4 - 20 mA/IO-Link
- Range:0 - 2/5/6 L/min (Detection range water/glycol/oil)
- Temperature range:0...60 °C (Ambient temperature); 0...60 °C (Medium temperature)
- Description:Flow rate sensor, SDNC 503/2 GANPL, 3,5 mm (Int.Ø)
- Connection:M12 connector (Electrical connection)
- Response time:0,5 - 10 s
- Pk:1
- Housing material:PBT
- Fluid type:Water, water/glycol/oil, non liner
Specifications
About this item
SDNC 500 sensors with IO-Link interface are the smart solution for process monitoring. They can record the flow speed and temperature in fluid mediums. To do so, there is a configuration soft- ware which configures the sensors via an IO-Link/USB master.
- Limit value and range monitoring for flow rate and temperature
- Adjustable delay for the switching signal
- Analog output scalable for flow rate or temperature
- Pulse output for flow rate
- Logical linking of flow rate and temperature monitoring
- Teach commands for determining the limit and range values
- TAG identification programmable
- Available in the SIO mode analog and switching output
The GAPL models provide flow data for liquid mediums as a linear output signal. The detection range of sensors suitable for all liquid media can be freely configured. Their output signal is not linear.
The flow rate sensors have a G1/4 process connection and can be easily integrated with hoses or pipe connectors in pipes. A special flow adapter shapes the flow profile and ensures a stable signal for the SDNC 502/503/506 GAPL.
In the SDNC 508 GAPL a straight inlet section of 100 mm is sufficient to achieve the specifications. The measuring range of the GANPL variants can be adapted to almost all media. A non-linear signal path results. The robust construction makes the sensors not sensitive to moisture and vibrations.