Refrigerated/heating circulators, DYNEO™ DD series
DYNEO™ DD refrigerated circulators are powerful cooling units suitable for internal or external applications between –50 and +200 °C. The circulators function precisely and reliably even at elevated ambient temperatures up to +40 °C. The multilingual 8,89 cm colour display and unique rotary knob allow straightforward and intuitive operation. Units have ergonomic handles and a built in drain tap for easy and safe drainage.
- Optimised cooling coil design saves space in the bath tank
- Powerful and infinitely adjustable pressure pump
- Easy to switch between internal and external circulation
- Large colour TFT display, multilingual user interface and USB port
- Central rotary knob (controller) simplifies operation
- Integrated programmer for 8×60 program steps
- Integrated external PT100 connection
- RS232 interface or analogue interface (optional)
- Choice of models with environmentally-friendly natural refrigerant
Max. flow rate/max. pressure:
DD: 8 to 27 L/min, 0,1 to 0,7 bar.
Certifications: Classification III according to DIN 12876-1
IP protection class according to DIN EN 60529: IP 21.
Ordering information: An extensive range of accessories mean that the circulators can be modularly and individually adapted to applications.
Delivery information: Supplied with bath cover and two each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16×1 male).
Caution: NOTE: Cooling capacity at +20, 0, −10, −20, −30 and −40 °C.
DYNEO™ DD refrigerated circulators are powerful cooling units suitable for internal or external applications between –50 and +200 °C. The circulators function precisely and reliably even at elevated ambient temperatures up to +40 °C. The multilingual 8,89 cm colour display and unique rotary knob allow straightforward and intuitive operation. Units have ergonomic handles and a built in drain tap for easy and safe drainage.
- Optimised cooling coil design saves space in the bath tank
- Powerful and infinitely adjustable pressure pump
- Easy to switch between internal and external circulation
- Large colour TFT display, multilingual user interface and USB port
- Central rotary knob (controller) simplifies operation
- Integrated programmer for 8×60 program steps
- Integrated external PT100 connection
- RS232 interface or analogue interface (optional)
- Choice of models with environmentally-friendly natural refrigerant
Max. flow rate/max. pressure:
DD: 8 to 27 L/min, 0,1 to 0,7 bar.
Certifications: Classification III according to DIN 12876-1
IP protection class according to DIN EN 60529: IP 21.
Ordering information: An extensive range of accessories mean that the circulators can be modularly and individually adapted to applications.
Delivery information: Supplied with bath cover and two each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16×1 male).
Caution: NOTE: Cooling capacity at +20, 0, −10, −20, −30 and −40 °C.
Documents
DYNEO™ Refrigerated and Heating Circulators
Additional Product Details
Julabo CORIO DYNEO MAGIO Heating and Refrigerated Circulators
Product Literature
- Catalog No:
- 461-1388
- 461-1389
- 461-1390
- 461-1391
- 461-1392
- 461-1394
- 461-1401
- 461-1402
- 461-1403
- 461-1404
- 461-1405
- 461-1407
- 461-1415
- 461-1416
- 461-1417
- 461-1418
- 461-1419
- 461-1421
- JULA9021713.S1.A
- JULA9021714.S1.A
- JULA9021701.N1
- JULA9021713.N1
- JULA9021714.N1
- JULA9021715.N1
- JULA9021716.N1
- JULA9021717.N1
- JULA9021728.N1
- JULA9021701.N1.A
- JULA9021713.N1.A
- JULA9021714.N1.A
- JULA9021715.N1.A
- JULA9021716.N1.A
- JULA9021717.N1.A
- JULA9021728.N1.A
- JULA9021701.N1.D
- JULA9021715.N1.D
- JULA9021717.N1.D
- JULA9021728.N1.D
- JULA9021713.S1.D
- JULA9021714.S1.D
- JULA9021713.N1.D
- JULA9021714.N1.D
- JULA9021716.N1.D
- JULA9021713.S1
- JULA9021714.S1
- Environmentally Preferable:
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
- Safer Human and Environmental Health
Product Family Options
Standard models
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 160,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1388Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-201F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm440×410×440 mm25,7 kg1 * 1 items5 130,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1389Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-300F–25...+200 °C±0,01 °C2 kW0,3 kW3 - 4 LR134a130×150×150 mm240×420×660 mm27,7 kg1 * 1 items5 770,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1390Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-600F–35...+200 °C±0,01 °C2 kW0,6 kW5 - 7,5 LR449A220×150×150 mm330×470×690 mm35,7 kg1 * 1 items6 810,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1391Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-601F–35...+200 °C±0,01 °C2 kW0,6 kW8 - 10 LR449A220×150×150 mm360×460×740 mm38,2 kg1 * 1 items7 230,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1392Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1000F–50...+200 °C±0,01 °C21,0 kW5 - 7,5 LR449A180×130×150 mm420×490×700 mm51,2 kg1 * 1 items8 970,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1394Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
DYNEO™ DD models with analogue option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 610,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1401Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-201F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm440×410×440 mm25,7 kg1 * 1 items5 580,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1402Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-300F–25...+200 °C±0,01 °C2 kW0,3 kW3 - 4 LR134a130×150×150 mm240×420×660 mm27,7 kg1 * 1 items6 220,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1403Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-600F–35...+200 °C±0,01 °C2 kW0,6 kW5 - 7,5 LR449A220×150×150 mm330×470×690 mm35,7 kg1 * 1 items7 260,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1404Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-601F–35...+200 °C±0,01 °C2 kW0,6 kW8 - 10 LR449A220×150×150 mm360×460×740 mm38,2 kg1 * 1 items7 680,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1405Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1000F–50...+200 °C±0,01 °C2 kW1,0 kW5 - 7,5 LR449A180×130×150 mm420×490×700 mm51,2 kg1 * 1 items9 420,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1407Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
DYNEO™ DD models with RS232 option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 420,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1415Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-201F–20...+200 °C±0,01 °C2 kW0,2 kW3 - 4 LR134a130×150×150 mm440×410×440 mm25,7 kg1 * 1 items5 390,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1416Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-300F–25...+200 °C±0,01 °C2 kW0,3 kW3 - 4 LR134a130×150×150 mm240×420×660 mm27,7 kg1 * 1 items6 030,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1417Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-600F–35...+200 °C±0,01 °C2 kW0,6 kW5 - 7,5 LR449A220×150×150 mm330×470×690 mm35,7 kg1 * 1 items7 070,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1418Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-601F–35...+200 °C±0,01 °C2 kW0,6 kW8 - 10 LR449A220×150×150 mm360×460×740 mm38,2 kg1 * 1 items7 490,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1419Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1000F–50...+200 °C±0,01 °C2 kW1,0 kW5 - 7,5 LR449A180×130×150 mm420×490×700 mm51,2 kg1 * 1 items9 230,00 €
Safer Human and Environmental Health Specifications
Cat. No.461-1421Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
Models with analogue interface option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 090,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.S1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 580,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.S1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
Models with natural refrigerant
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C1 kW0,2; 0,17; 0,15; 0,1; 0,02 kW3 - 4 LR290130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 010,00 €
Specifications
Cat. No.JULA9021701.N1Environmentally Preferable - DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items5 640,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.N1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 130,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.N1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-800F–40...+200 °C±0,01 °C2 kW0,84; 0,74; -; 0,39; 0,24; 0,1 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items7 730,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021715.N1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-449F–32 ... +200 °C±0,01 °C2 kW0,44; 0,35; 0,27; 0,2; 0,06 kW21 - 30 LR290280×350×200 mm370×590×690 mm39,5 kg1 * 1 items7 140,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021716.N1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200F–50...+200 °C±0,01 °C2 kW1,24; 1,09; -; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items9 040,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021717.N1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200FW–50...+200 °C±0,01 °C1 kW1,24; 1,09; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm391×231×701 mm44 kg1 * 1 items10 980,00 €
Specifications
Cat. No.JULA9021728.N1Environmentally Preferable
Models with natural refrigerant and analogue interface option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C1 kW0,02 - 0,2 kW3 - 4 LR290130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 460,00 €
Specifications
Cat. No.JULA9021701.N1.AEnvironmentally Preferable - DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 090,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.N1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 580,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.N1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-800F–40...+200 °C±0,01 °C2 kW0,84; 0,74; -; 0,39; 0,24; 0,1 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items8 180,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021715.N1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-449F–32 ... +200 °C±0,01 °C2 kW0,44; 0,35; 0,27; 0,2; 0,06 kW21 - 30 LR290280×350×200 mm370×590×690 mm39,5 kg1 * 1 items7 590,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021716.N1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200F–50...+200 °C±0,01 °C2 kW1,24; 1,09; -; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items9 490,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021717.N1.AEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200FW–50...+200 °C±0,01 °C1 kW1,24; 1,09; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm391×231×701 mm44 kg1 * 1 items11 430,00 €
Specifications
Cat. No.JULA9021728.N1.AEnvironmentally Preferable
Models with natural refrigerant and digital interface option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-200F–20...+200 °C±0,01 °C1 kW0,02 - 0,2 kW3 - 4 LR290130×150×150 mm230×390×650 mm25,7 kg1 * 1 items5 270,00 €
Specifications
Cat. No.JULA9021701.N1.DEnvironmentally Preferable - DD-800F–40...+200 °C±0,01 °C2 kW0,84; 0,74; -; 0,39; 0,24; 0,1 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items7 990,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021715.N1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200F–50...+200 °C±0,01 °C2 kW1,24; 1,09; -; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm330×470×700 mm42 kg1 * 1 items9 300,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021717.N1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-1200FW–50...+200 °C±0,01 °C1 kW1,24; 1,09; 0,62; 0,37; 0,2 kW5 - 7,5 LR1270180×130×150 mm391×231×701 mm44 kg1 * 1 items11 240,00 €
Specifications
Cat. No.JULA9021728.N1.DEnvironmentally Preferable
Models with RS232 interface option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items5 900,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.S1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 390,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.S1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
Models with natural refrigerant and RS232 interface option
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items5 900,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.N1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR290130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 390,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.N1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-449F–32 ... +200 °C±0,01 °C2 kW0,44; 0,35; 0,27; 0,2; 0,06 kW21 - 30 LR290280×350×200 mm370×590×690 mm39,5 kg1 * 1 items7 400,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021716.N1.DEnvironmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health
- TypeTemperature RangeTemp. stabilityHeating capacityCooling capacityCapacityRefrigerantBath W×D×HW×D×HWeight
- DD-310F–30...+200 °C±0,01 °C2 kW0,3; 0,27; 0,21; 0,12; 0,02 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items5 640,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021713.S1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health - DD-450F–30...+200 °C±0,01 °C2 kW0,44; 0,37; 0,27; 0,16; 0,06 kW3 - 4 LR449A130×150×150 mm230×400×650 mm27,4 kg1 * 1 items6 130,00 €
Safer Human and Environmental Health Specifications
Cat. No.JULA9021714.S1Environmentally PreferableSafer Human and Environmental HealthSafer Human and Environmental Health