These bench top meters with conductivity module meet most challenging applications for pH, ion concentration, mV, ORP and temperature. The meters offer interchangeable measurement modules that allow multiple users to customise four separate channels to meet their specific requirements.
- Colour display with adjustable text sizes; numeric keypad; onscreen measurement stability indicator
- Auto-read to hold a stable reading; ten password-protected methods per channel
- Audible alarms automatically notify users when a set offset value, high/low limit value, and calibration time interval are reached
- Data log collects and date/time stamps up to 2000 measurement sets with optional electrode ID, sample ID and account ID
- Calibration log stores ten most recent calibrations per parameter with viewable graph for multipoint pH and ISE calibrations
- Advanced ISE features include non-linear selectable auto-blank, low range stability and electrode ID with calibration verification
- Meter facilitates data transfers to a computer via USB or RS232 connections
IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.
When used in conjunction with the Orion navigator pro software, the Orion versa star pro meter is designed to create electronic data records and audit trails with password-protection, which can be used to assist with 21 CFR Part 11 requirements when paired with each laboratory's proper IT protocols, SOPs and training records.* Orion navigator pro software offers multi-level system access for an administrator and up to 10 users. The system administrator can customise each user's access level from full system access to basic data collection only. The navigator pro software controls all meter functions including meter settings, calibration, measurement, and reporting to help ensure data integrity and provide a complete audit trail.
Features and benefits
- Generates electronic records and signatures
- Creates audit trail report for electronic records
- Limits access to authorized individuals
- Password protection with system administrator and up to 10 users
- Full computer control of meter functions including setup, calibration and measurement
- Paperless record keeping system
Temperature (metric) operating: 5 to 45 °C (ambient). Isopotential point: 7,000 pH (adjustable), 1,000 ISE (adjustable). Three year meter and module warranty.
- Catalog No:
- 662-2309
- 662-2306
- 662-2307
- 662-2308
- Model:
- Orion™ Versa Star™ Pro™, with pH/ISE module
- Orion™ Versa Star™ Pro™, with pH/ISE module
- Orion™ Versa Star™ Pro™, with pH/ISE module
- Orion™ Versa Star™ Pro™, with pH/ISE module
- pH range:
- −2,000...+20,000
- −2,000...+20,000
- −2,000...+20,000
- −2,000...+20,000
- pH resolution:
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- pH accuracy:
- ±0,002
- ±0,002
- ±0,002
- ±0,002
- pH calibration:
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Up to 6 points
- mV range:
- ±2000,0
- ±2000,0
- ±2000,0
- ±2000,0
- mV resolution:
- 0,1
- 0,1
- 0,1
- 0,1
- mV accuracy:
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- ISE range:
- 0,0001 - 19990
- 0,0001 - 19990
- 0,0001 - 19990
- 0,0001 - 19990
- ISE resolution:
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- ISE accuracy:
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ISE calibration:
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Up to 6 points
- ISE units:
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- Temperature range:
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- Temperature resolution:
- 0,1 °C, 0.1 °F
- 0,1 °C, 0.1 °F
- 0,1 °C, 0.1 °F
- 0,1 °C, 0.1 °F
- Temperature accuracy:
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- Temperature calibration:
- 1 point offset
- 1 point offset
- 1 point offset
- 1 point offset
- Temperature compensation:
- Manual or automatic with ATC temperature probe
- Manual or automatic with ATC temperature probe
- Manual or automatic with ATC temperature probe
- Manual or automatic with ATC temperature probe
- Display:
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Power supply:
- Universal AC adapter (included)
- Universal AC adapter (included)
- Universal AC adapter (included)
- Universal AC adapter (included)
- Compliance:
- IP 54
- IP 54
- IP 54
- IP 54
- Operating temperature range:
- 41...113 °F (ambient)
- 41...113 °F (ambient)
- 41...113 °F (ambient)
- 41...113 °F (ambient)
- Data logging - log function:
- Automatic data logging with auto-read, timed and single shot measure modes; manual data logging with continuous measure mode
- Automatic data logging with auto-read, timed and single shot measure modes; manual data logging with continuous measure mode
- Automatic data logging with auto-read, timed and single shot measure modes; manual data logging with continuous measure mode
- Automatic data logging with auto-read, timed and single shot measure modes; manual data logging with continuous measure mode
- Data logging capacity:
- 2000 points
- 2000 points
- 2000 points
- 2000 points
- Memory:
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Languages:
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- Dimensions:
- 28×24×10 cm (11×9,5×3,9"), modules add ≤ 2 cm (0,8") L and H
- 28×24×10 cm (11×9,5×3,9"), modules add ≤ 2 cm (0,8") L and H
- 28×24×10 cm (11×9,5×3,9"), modules add ≤ 2 cm (0,8") L and H
- 28×24×10 cm (11×9,5×3,9"), modules add ≤ 2 cm (0,8") L and H
- Connections:
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- Outputs:
- RS232, USB (2)
- RS232, USB (2)
- RS232, USB (2)
- RS232, USB (2)
- Input:
- Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)
- Alarm:
- Set point alarm, high/low limit alarm, calibration due alarm
- Set point alarm, high/low limit alarm, calibration due alarm
- Set point alarm, high/low limit alarm, calibration due alarm
- Set point alarm, high/low limit alarm, calibration due alarm
- Calibration:
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- Calibration points:
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- W×D×H:
- 280×240×100 mm
- 280×240×100 mm
- 280×240×100 mm
- 280×240×100 mm
- Weight:
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)