201 Results for: "Solid Phase Extraction"
Solid phase extraction cartridges, Bond Elut™ C18
Supplier: VARIAN
Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.
Expand 43 Items
Solid phase extraction cartridges, Bond Elut™ Diol
Supplier: VARIAN
Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ NH₂
Supplier: VARIAN
Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.
Expand 24 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
Solid phase extraction cartridges, Bond Elut™ Certify II
Supplier: VARIAN
Bond Elut™ Certify II was developed specifically for the rapid and effective extraction of acidic drugs and metabolites from urine and other biological matrices. Certify II is a mixed-mode cartridge packed with non-polar C8 and strong anion exchange (SAX) sorbent. It has been optimised for acidic drugs such as 11-nor-delta-9-tetrahydrocannibinol-carboxylic acid, salicylic acid, ibuprofen, acetaminophen and other compounds that possess both non-polar and anionic characteristics.
Expand 11 Items
Accessories for solid phase extraction cartridges, Bond Elut™ SPEC
Supplier: VARIAN
Bond Elut™, Environmental disk manifold
Expand 3 Items
Solid phase extraction cartridges, Bond Elut™ C18 EWP
Supplier: VARIAN
Bond Elut™ EWP is based upon standard particle size silica but with 500 Å pores to allow more efficient extraction of large molecules (>15000 MW), which are typically excluded from standard porosity silica phases.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ C18 OH
Supplier: VARIAN
Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ Plexa PCX
Supplier: VARIAN
Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.
Expand 11 Items
Solid phase extraction cartridge, Sep-Pak® XPoSure™ Plus
Supplier: WATERS
Specially designed for monitoring aldehydes in indoor air.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying
Supplier: VARIAN
Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX
Supplier: VARIAN
Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.
Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.
Expand 8 Items
Empty solid phase extraction cartridges with two frits, Bond Elut™
Supplier: VARIAN
Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.
Expand 7 Items
J.T.Baker® BAKERBOND spe™ PCB-N, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction of PCB’s in oil.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ PCB-A, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction of PCB’s in oil (dirty samples) in combination with SPE silica gel.
Expand 1 Items
SPE columns, CHROMABOND® CN
Supplier: MACHEREY-NAGEL
CHROMABOND® CN is a cyanopropyl modified silica phase for solid phase extraction.
Expand 2 Items
Aluminium oxide activated neutral Brockmann Grade I, Supelco®
Supplier: Merck
Brockmann aluminum oxides are suitable for column chromatography and adsorptive filtration. Aluminum oxides are generally used as solid support phases in solid phase extraction (SPE)-based clean-up procedures employed in chromatographic methods
Expand 2 Items
Positive pressure manifold, ASPEC®
Supplier: GILSON LCMS
The ASPEC® Positive pressure manifold uses positive pressure to improve reproducibility and recovery for solid phase extraction (SPE) applications.
Expand 1 Items
Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®
Supplier: Merck
Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ SDB, SPE Columns, Polymer Based
Supplier: Avantor
Solid phase extraction, as a sample preparation technique, often requires stationary phases stable in the whole pH range. Styrene-divinylbenzene (SDB) copolymer sorbent can improve the quality of sample preparation.
Expand 11 Items
Extraction unit and drying attachment, LiChrolut®
Supplier: Merck
All the individual steps associated with solid phase extraction can be carried out using the LiChrolut® extraction unit. This transparent and vacuum-suitable unit, made of glass, can be used to prepare up to 12 samples simultaneously.
Expand 3 Items
Flash cartridges, Mega Bond Elut™
Supplier: VARIAN
Flash cartridges for the purification of organic compounds, and also for scale-up, solid phase extraction.
Expand 24 Items
Cerex® FLORASIL SPE Columns
Supplier: Tecan
Florisil is used for sample preparation (solid phase extraction) of e.g., organic tin compounds and aliphatic carboxylic acids. Florisil is a magnesium silicate.
Expand 1 Items
ASPEC® 241 system
Supplier: GILSON LCMS
This compact ASPEC® system combines positive pressure solid phase extraction (SPE) with small footprint and precise liquid handling for reliable automated SPE applications.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ PAH Soil, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from soil, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ PAH Aqua, SPE Columns for Special Applications
Supplier: Avantor
These solid phase extraction columns are designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from water, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.
Expand 1 Items
Organic reference standard, 4-Hydroxy-4-methyl-2-pentanone, analytical standard, Supelco®
Supplier: Merck
4-Hydroxy-4-methyl-2-pentanone may be used as an internal standard in the analysis of volatile odor-active compounds present in wine using solid phase extraction with gas chromatography (SPE-GC).
Expand 1 Items
Sample delivery system, Resprep®
Supplier: Restek
This sample delivery system is used to transfer large volumes of low viscosity samples directly from a bottle to a solid phase extraction cartridge or to a disk on a vacuum manifold system for extraction or cleanup.
Expand 1 Items
Organic reference standard, Bisphenol E, analytical standard, Supelco®
Supplier: Merck
Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).
Expand 1 Items
J.T.Baker® BAKERBOND spe™ Carbon-Amino, SPE Columns for Special Applications
Supplier: Avantor
BAKERBOND spe™ Amino-Carbon is a double-phase solid extraction column packed with spherical activated carbon (lower layer) and aminopropyl modified silica phase (upper layer) of polar, weak anion properties. Designed for pesticide residue analysis in agricultural product.