Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Solid phase extraction cartridges, Bond Elut™ PBA
Supplier: VARIAN
PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ PRS
Supplier: VARIAN
Bond Elut™ PRS is a strong cation exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in non-polar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, a high ionic strength eluent must be used, and so the use of PRS is recommended for weaker cationic species such as pyridinium compounds.
Expand 7 Items
Solid phase extraction cartridges, Bond Elut™ Plexa
Supplier: VARIAN
The water-wettable, hydroxylated exterior allows excellent flow, even with biological fluids. A gradient of polarity on the polymer surface shunts small analytes to the more hydrophobic centre of the polymer bead, where they are retained prior to the washing and elution steps. Plexa provides these performance enhancements due to a unique polymeric architecture with a non-retentive, hydroxylated, amide-free surface and a non-polar PS/DVB core for retaining small molecules.
Expand 11 Items
Solid phase extraction cartridges, Bond Elut™ Certify II
Supplier: VARIAN
Bond Elut™ Certify II was developed specifically for the rapid and effective extraction of acidic drugs and metabolites from urine and other biological matrices. Certify II is a mixed-mode cartridge packed with non-polar C8 and strong anion exchange (SAX) sorbent. It has been optimised for acidic drugs such as 11-nor-delta-9-tetrahydrocannibinol-carboxylic acid, salicylic acid, ibuprofen, acetaminophen and other compounds that possess both non-polar and anionic characteristics.
Expand 11 Items
Solid phase extraction cartridges, Bond Elut™ C1
Supplier: VARIAN
Due to the methyl group and subsequent low carbon load, Bond Elut™ C1 is the least retentive of all alkyl group bonded phases for non-polar compounds. However, due to the extensive end capping of this sorbent to mask polar silanol activity, retention and elution of polar and multi-functional analytes can still be achieved. Typical applications include plasma, urine and aqueous samples.
Expand 3 Items
Gel permeation chromatography columns, Styragel® HR
Supplier: WATERS
Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.
Expand 7 Items
Reversed phase HPLC columns, Atlantis® Silica HILIC
Supplier: WATERS
Atlantis HILIC silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography.
Expand 2 Items
Preparative columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 1 Items
Analytical HPLC columns, Nova-Pak® C18
Supplier: WATERS
Nova-Pak® C18 columns are general purpose, silica based, reversed phase C18 columns that are based on 4 µm particle technology.
Expand 5 Items
Analytical HPLC columns, XTerra® MS C8
Supplier: WATERS
XTerra® MS C8 columns are general purpose, hybrid-based, reversed phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 2 Items
Analytical HPLC columns, XTerra® RP18
Supplier: WATERS
XTerra® RP18 columns are general purpose, hybrid-based, reversed phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 6 Items
Analytical HPLC columns, Symmetry® C18
Supplier: WATERS
Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.
Expand 13 Items
UPLC columns, ACQUITY UPLC™ BEH Shield RP 18
Supplier: WATERS
These columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Expand 2 Items
Solid phase extraction cartridge, Sep-Pak® XPoSure™ Plus
Supplier: WATERS
Specially designed for monitoring aldehydes in indoor air.
Expand 1 Items
Analytical HPLC columns, XBridge™ BEH C18
Supplier: WATERS
XBridge™ BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Expand 7 Items
Analytical HPLC columns, SunFire™ C8
Supplier: WATERS
SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.
Expand 2 Items
Analytical HPLC columns, XBridge™ BEH C8
Supplier: WATERS
The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.
Expand 3 Items
UPLC columns, ACQUITY UPLC™ BEH phenyl
Supplier: WATERS
These columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds.
Expand 4 Items
Analytical HPLC columns, XSelect™ CSH C18
Supplier: WATERS
XSelect™ CSH C18 is a general purpose column that provides alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps to overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed and slow mobile-phase re-equilibration.
Expand 2 Items
Reversed phase HPLC columns, Atlantis® T3
Supplier: WATERS
Atlantis T3 columns are universal, silica based, reversed phase C18 columns that provide balanced retention of polar and hydrophobic molecules and useful for developing separations of polar and non-polar compounds.
Expand 8 Items
Reversed phase HPLC columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 4 Items
Analytical HPLC columns, Symmetry® C8
Supplier: WATERS
Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.
Expand 5 Items
Analytical HPLC columns, SunFire™ C18
Supplier: WATERS
SunFire™ columns provide symmetrical peak shapes for improved resolution. With new bonding and endcapping technologies, they offer great efficiency for acid, neutral, and basic compounds at low and intermediate pH ranges. They are compatible with mass spectrometry applications, providing sharp peaks, high sensitivity, large peak capacities and very low bleed.
Expand 11 Items
Reversed phase HPLC columns, Atlantis® dC18
Supplier: WATERS
Atlantis® dC18 columns are universal, silica-based, reversed phase C18 columns that are used for polar compound retention. The Atlantis® dC18 columns feature di-functionally bonded C18 ligands that have been optimised for use with highly aqueous mobile phases, including 100% water.
Expand 8 Items
UPLC columns, ACQUITY UPLC™ BEH C8
Supplier: WATERS
The particals and chemistries of the ACQUITY UPLC columns are used to separate and with maximum speed, sensitivity and resolution without compromise, it produce the ideal combination of ultra performance efficiencies wide complementary selectivities.
Expand 3 Items
Analytical HPLC columns, Nova-Pak® phenyl
Supplier: WATERS
These columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.
Expand 1 Items
Gel permeation chromatography clean-up columns, Envirogel™
Supplier: WATERS
The Envirogel™ High-Resolution GPC cleanup columns are specifically designed to remove low volatility, high molecular weight interferences such as lipids and natural resins from environmental samples as specified in EPA method 3640A.
Expand 1 Items
Solid phase extraction cartridges, Sep-Pak® Vac
Supplier: WATERS
These cartridges deliver the option of minimum sample preparation. Consists of moulded, high purity PP syringe-barrel bodies with two PE frits to contain the packing material.
Expand 7 Items
UPLC columns, ACQUITY UPLC™ CSH phenyl-hexyl
Supplier: WATERS
These columns provides complementary selectivity to straight-chain-alkyl phases, particularly for polyaromatic compounds. Built on Charged Surface Hybrid (CSH) particle platform.
Expand 1 Items
Solid phase extraction cartridges, Oasis® WCX
Supplier: WATERS
These cartridges contain the Oasis® WCX sorbent, which is a polymeric reversed phase, weak ion exchange mixed mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong basic compounds and quaternary amines.