You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Diatomaceous earth sorbents, Chem Elut™ and Hydromatrix™
Supplier: VARIAN
Chem Elut sorbent for rapid, general sample preparation of biological samples such as plasma, serum, whole blood and urine. Chem Elut products are available in buffered and unbuffered formats. The buffered devices can be used for simple scrubbing operations on organic reactions. The base-treated cartridge can remove residual acid compounds from a variety of matrices.
Expand 18 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
Solid phase extraction cartridges, Bond Elut™ Focus
Supplier: VARIAN
Bond Elut™ Focus solid phase extraction cartridges with enhanced polar recovery. Features a unique amide functionalised polar-enhanced sorbent technology that delivers outstanding retention for polar and non-polar analytes.
Expand 4 Items
PLOT columns, CP-PoraPLOT U and CP-PoraPLOT S
Supplier: VARIAN
CP-PoraPLOT U and CP-PoraPLOT S provide symmetrical peaks from polar and non-polar volatiles for ultimate accuracy.
Expand 6 Items
PLOT column particle traps
Supplier: Restek
When extreme pressure shocks and gas flow changes are anticipated there is a possibility for particles to dislodge. In those cases, using particle traps is recommended.
Expand 2 Items
Analytical HPLC columns, Inertsil®
Supplier: GL Sciences B.V.
Inertsil® series phases are based on a purer, higher surface area silica which is specially manufactured to provide maximum phase coverage. The result is a series of columns which provide excellent peak shapes using simple eluents while operating at low pressure.
Expand 2 Items
Capillary columns, CP-Sil 88 for FAME
Supplier: VARIAN
Guaranteed analysis of FAME cis/trans isomers for complete confidence.
Expand 3 Items
HPLC Columns, Raptor™ ARC-18
Supplier: Restek
Raptor™ ARC 18 columns are ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
Expand 15 Items
Capillary columns, MXT®-2887
Supplier: Restek
These MXT-2887 columns stationary phase, column dimensions, and film thicknesses have been optimised to exceed the resolution and skewing factor requirements. Siltek-treated stainless steel tubing.
Expand 1 Items
HPLC columns, Polaris™ amide C18
Supplier: VARIAN
Polaris™ amide C18 has the greatest polarity of the Polaris™ C18 family. The amide polar groups offer a different selectivity from either the C18-A or C18-ether phases. The surface has been covalently modified with alkyl amide groups and endcapped.
Expand 32 Items
HPLC columns, Ultra IBD (USP L68)
Supplier: Restek
Ultra IBD is a polar-embedded column that acts as a strong hydrogen bonder. With a unique polar group this column is very retentive and selective for acids. It also provides symmetrical peak shape for strong bases. This columns are compatible with 100% aqueous mobile phases and can be used under reversed-phase or HILIC conditions to retain very polar, ionic compounds in highly organic mobile phases.
Expand 31 Items
Analytical HPLC columns, Microsorb™ C18
Supplier: VARIAN
Microsorb™ C18 is an octadecylsilane-covered silica that has been bonded using monofunctional bonding agents under optimised conditions. This material is then endcapped with trimethylsilyl groups to minimise nonspecific binding, maximise mass recoveries and improve peak shape.
Expand 4 Items
UHPLC columns, Pinnacle® DB C8 (USP L7)
Supplier: Restek
Highly base-deactivated spherical silica manufactured by Restek. Monomeric C8 bonding. Similar to Pinnacle® DB C18, but the shorter alkyl chain provides less hydrophobic retention. Less retention can be useful for shortening analysis time, if resolution is adequate. Replaces Hypersil® BDS C8 and Pinnacle® C8 Amine.
Expand 59 Items
Solid phase extraction cartridges, Bond Elut™ PCB
Supplier: VARIAN
Bond Elut™ PCB is a specially designed sorbent which allows for the facile extraction of polychlorinated biphenyl (PCB) compounds from a variety of matrices. Desired analytes can be loaded and eluted using a simple, single solvent method prior to analysis by GC/ECD.
Expand 1 Items
HPLC columns, MetaSil AQ C18
Supplier: VARIAN
The MetaSil AQ materials are based on silica that is highly coated with hydrophobic alkyl chains interspersed with hydrophilic short-chain endcapping groups. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase. These columns remain fully extended in aqueous phases, allowing increased interaction between samples and the bonded phase.
Expand 2 Items
HPLC columns, Pursuit™
Supplier: VARIAN
These Pursuit™ columns are ideal for analysing lead compounds and biological samples. The need for ion pairing agents such as TFA is often eliminated, thus maximising the performance of single and parallel multi-channel LC/MS systems.
Expand 144 Items
Solid phase extraction cartridges, Bond Elut™ C2
Supplier: VARIAN
Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.
Expand 10 Items
Preparative HPLC columns, Ultra Biphenyl
Supplier: Restek
These biphenyl columns offer a greater degree of dispersion than conventional phenyls and a greater degree of polarizability than phenyl hexyls, creating higher selectivity and a greater range of usability. Because of these heightened interactions, this column shows substantial increases in retention—especially for dipolar, unsaturated, or conjugated solutes—and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 3 Items
GC columns, Stabilwax-MS (fused silica)
Supplier: Restek
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels. Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
Expand 1 Items
HPLC columns, Polaris™ C8-A
Supplier: VARIAN
These Polaris™ phases have rapid high resolution separations based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 25 Items
HPLC columns, Polaris™ C18-A
Supplier: VARIAN
The Polaris C18-A phase is specially designed for high-throughput and LC/MS analysis of polar analytes in drug discovery, drug metabolism, and AR&D areas.
Expand 48 Items
Preparative HPLC columns, Ultra Aqueous C18
Supplier: Restek
Ultra Aqueous C18 is a rugged, reversed phase column with a well balanced retention profile that boasts high reproducibility and compatibility with many mobile phase, even in 100% aqueous conditions.
Expand 12 Items
GC Columns, Rt-bDEXse™ (fused silica)
Supplier: Restek
Separations of more than one hundred chiral compounds have been achieved using our unique DEX columns, and DEX columns continue to demonstrate stability after hundreds of temperature program cycles. By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure cyclodextrin stationary phases. 2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane
Expand 2 Items
Force EXP Guard Column Cartridge
Supplier: Restek
Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connections, with no tools needed.
Expand 1 Items
CarboBlack columns (packed)
Supplier: Restek
Graphitised carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a non silicone liquid phase. CarboBlack C support can hold up to a 1% loading of a non silicone liquid phase.
Expand 10 Items
Gel Permeation Chromatography Columns, PL HFIPgel
Supplier: VARIAN
Hexafluoroisopropanol (HFIP) is used as a solvent in GPC for the analysis of important industrial polymers such as polyesters, polyamides and polylactide/glycolide copolymers. For greatly improved performance in extremely polar solvents such as HFIP and trifluoroethanol, we have developed novel 'multipore' technology to produce PL HFIPgel, a PS/DVB packing featuring a monodisperse particle size, high pore volume and high resolution.
Expand 1 Items
Solid phase extraction cartridges, EnvirElut™
Supplier: VARIAN
EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.
Expand 6 Items
Capillary columns, CP-Chirasil-Dex CB
Supplier: VARIAN
The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.
Expand 3 Items
Capillary columns, CP-Chirasil Val
Supplier: VARIAN
The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.
Expand 3 Items
Capillary columns, CP-Sil
Supplier: VARIAN
The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.