"SEC Chromatography"
Gel filtration media, Sephadex™ G-100
Supplier: Cytiva
Sephadex™ G-100 is useful for desalting and buffer exchange of very large biomolecules. Sephadex™ G-100 Superfine is designed for specific cases requiring very high resolution.
Expand 2 Items
Superose™ 6 Gel Filtration Media, Prep Grade
Supplier: Cytiva
Superose™ 6 PG for separations of proteins and other biomolecules according to size. Wide separation in two molecular weight ranges from 1000 up to 5 million.
Expand 1 Items
Gel filtration media, Sephacryl™ High Resolution
Supplier: Cytiva
Sephacryl™ High Resolution (HR) gel filtration media allow fast and reproducible purification of proteins, polysaccharides, and other macromolecules by gel filtration at laboratory and industrial scale.
Expand 10 Items
Size exclusion chromatography columns, illustra™ NAP™
Supplier: Cytiva
NAP™ columns are disposable columns prepacked with Sephadex™ G-25 DNA grade and require only gravity to run.
Expand 6 Items
Pre-packed columns, 1 and 5 ml, SkillPak™
Supplier: TOSOH Bioscience
SkillPak 1 and 5 ml columns are designed for fast method development, resin screening or sample concentration. Pre-packed with TOYOPEARL®, TSKgel® or Ca++Pure-HA™ process chromatography media, these columns offer superior separation of biomelocules, such as monoclonal antibodies, proteins and oligonucleotides. SkillPak 50 and 200 ml pre-packed columns are the best solution for seamless scale up of methods developed on SkillPak 1 and 5.
Expand 2 Items
Sepharose™ 6B Gel Filtration Base Matrix
Supplier: Cytiva
Sepharose™ 6B is an agarose gel filtration base matrix and is frequently used for coupling affinity ligands to the matrix. The matrix is not pre-activated and the user performs all steps in coupling.
Expand 1 Items
Sepharose™ 4B Gel Filtration Base Matrix
Supplier: Cytiva
Sepharose™ 4B is an agarose gel filtration base matrix and is frequently used for coupling affinity ligands to the matrix. The matrix is not pre-activated and the user performs all steps in coupling.
Expand 1 Items
Sepharose™ CL-2B Gel Filtration Base Matrix
Supplier: Cytiva
Sepharose CL-2B is a well-proven cross-linked agarose gel filtration base matrix and is frequently used for coupling affinity ligands to the matrix. The matrix is not pre-activated and the user performs all steps in coupling.
Expand 1 Items
Superose™ 12 Gel Filtration Media, Prep Grade
Supplier: Cytiva
Good resolution separations of proteins and other biomolecules according to size, Wide separation range – separations in two molecular weight ranges from 1,000 up to 5 million, Excellent reproducibility and durability
Expand 1 Items
Pierce™ Desalting Columns, Polyacrylamide
Supplier: Thermo Fisher Scientific
Protein desalting spin columns are designed to desalt or exchange buffer of protein samples with volumes of 30 to 120 µl. These devices have exceptional desalting characteristics with ≥95% retention of salts and small molecules while providing excellent recovery of proteins greater than 7 kDa. Multiple samples can be processed in less than five minutes without cumbersome column preparation steps.
Expand 3 Items
Desalting columns, HiPrep™
Supplier: Cytiva
HiPrep™ 26/10 desalting column is a convenient, easy to use column pre-packed with Sephadex™ G-25 Fine for desalting and buffer exchange with sample sizes of up to 15 ml per column.
Expand 2 Items
Columns, PD SpinTrap™ G-25
Supplier: Cytiva
PD SpinTrap G-25 is a single-use column for cleanup of large biomolecules.
Expand 1 Items
Gel filtration columns, HiPrep™ with Sephacryl® S-200 HR
Supplier: Cytiva
HiPrep™ 16/60 Sephacryl® S-200 HR and HiPrep™ 26/60 Sephacryl® S-200 HR are pre-packed gel filtration columns for preparative separation of biomolecules of up to 5 and 13 ml sample volume respectively. Sephacryl® S-200 is used for separating mid-size proteins including antibodies and serum proteins.
Expand 2 Items
Gel filtration columns, HiPrep™ with Sephacryl® S-400 HR
Supplier: Cytiva
HiPrep™ 16/60 Sephacryl® S-400 HR and HiPrep™ 26/60 Sephacryl® S-400 HR are pre-packed gel filtration columns for preparative separation of biomolecules of up to 5 and 13 ml sample volume respectively. Sephacryl® S-400 is used for separating polysaccarides, macromolecules with extended structures, and even small plasmids.
Expand 2 Items
Gel filtration columns, HiPrep™ with Sephacryl® S-500 HR
Supplier: Cytiva
HiPrep™ 16/60 Sephacryl S-500 HR and HiPrep™ 26/60 Sephacryl® S-500 HR are pre-packed gel filtration columns for preparative separation of biomolecules of up to 5 and 13 ml sample volume respectively. Sephacryl® S-500 is used for separating polysaccarides, macromolecules with extended structures, and even small plasmids.
Expand 2 Items
Columns, PD MiniTrap™ G-10
Supplier: Cytiva
PD MiniTrap G-10 columns are prepacked, single-use gravity columns for buffer exchange and cleanup of biological samples, for example peptides, small proteins, and oligosaccharides.
Expand 1 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".