Order Entry
Denmark
ContactUsLinkComponent
11425 results for "Restek"

 

Sort By
Pharmaceutical mix #2 (4 components)

Pharmaceutical mix #2 (4 components)

Supplier: Restek

This pharmaceutical mix #2 contains four components: Gemfibrozil, Ibuprofen, Naproxen and Triclosan.

Expand 1 Items
 
Canadian drinking water phenoxyacid herbicides mix (11 components)

Canadian drinking water phenoxyacid herbicides mix (11 components)

Supplier: Restek

Consists of 11 components, those are bromoxynil, 2,4-d, dicamba, 2,4-dichlorophenol, diclofop methyl, dinoseb, pentachlorophenol, picloram, 2,4,5-t, 2,3,4,6-tetrachlorophenol and 2,4,6-trichlorophenol.

Expand 1 Items
 

Chlorotrimethylsilane

Supplier: Restek

Chlorotrimethylsilane

Expand 1 Items
 
Capillary columns, Rtx®-624

Capillary columns, Rtx®-624

Supplier: Restek

Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.

Expand 21 Items
 
Deuterium lamps for HPLC systems

Deuterium lamps for HPLC systems

Supplier: Restek

Deuterium lamp, Longlife deuterium lamp, 2000 hours, For: 1100 DAD/MWD/1200/1260

Expand 15 Items
 
GC multi-residue pesticide standard #8 (24 components)

GC multi-residue pesticide standard #8 (24 components)

Supplier: Restek

The multiresidue accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

Expand 1 Items
 
GC multiresidue pesticide standard #4 (28 components)

GC multiresidue pesticide standard #4 (28 components)

Supplier: Restek

Organonitrogen compounds that has accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.

Expand 1 Items
 
Inlet liners, for Varian GCs

Inlet liners, for Varian GCs

Supplier: Restek

Use these liners for increased sensitivity. They are manufactured from borosilicate glass or metal.

Expand 75 Items
 

Tubing, fused silica

Supplier: Restek

Fused silica tubings are strength tested and economical. They are coiled in 7" diameters, banded in 5-meter sections and mounted in a cage.

Expand 9 Items
 
Capillary column caps

Capillary column caps

Supplier: Restek

These non-reusable column caps increase column lifetime, prevent moisture and air from entering the column during storage.

Expand 2 Items
 
Capillary adaptable FID jet

Capillary adaptable FID jet

Supplier: Restek

These capillary adaptable FID replacement jets are engineered with a fluted tip to guide the capillary column into the jet.

Expand 4 Items
 
GC columns, Rt®-βDEXcst (fused silica)

GC columns, Rt®-βDEXcst (fused silica)

Supplier: Restek

The Rt®-βDEXcst columns are specially designed for the fragrance industry and pharmaceutical applications.

Expand 2 Items
 
Capillary columns, Rt®-CW20M F and F (fused silica)

Capillary columns, Rt®-CW20M F and F (fused silica)

Supplier: Restek

Polar phase; Carbowax polyethylene glycol

Expand 2 Items
 

Capillary columns, Rtx®-BAC2 (fused silica)

Supplier: Restek

Application-specific columns for blood alcohol analysis - achieve baseline resolution in less than three minutes.

Expand 4 Items
 
GC columns, Rt-XLSulfur (packed and micropacked)

GC columns, Rt-XLSulfur (packed and micropacked)

Supplier: Restek

These Rt-XLSulfur columns are optimised for low ppbv sulfur analyses. Interior wall and the end fittings of Rt-XLSulfur columns are Sulfinert treated, making the column as inert as PTFE.

Expand 9 Items
 
Single - component oxygenates solutions

Single - component oxygenates solutions

Supplier: Restek

Certified reference materials (CRMs) manufactured and QC-tested in ISO-accredited labs satisfy your ISO requirements.

Expand 10 Items
 
TCLP Acid mix (6 components)

TCLP Acid mix (6 components)

Supplier: Restek

TCLP acid mix contains 2-methylphenol (o-cresol), 3-methylphenol (m-cresol), 4-methylphenol (p-cresol), pentachlorophenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol.

Expand 1 Items
 
Kerosene composite standards

Kerosene composite standards

Supplier: Restek

Kerosene composite standards are comprised of three separate sources blended in equal portions. It may exhibit lot-to-lot variation.

Expand 9 Items
 
610 PAH calibration mix A (16 components)

610 PAH calibration mix A (16 components)

Supplier: Restek

610 PAH calibration mix A contains acenaphthene (1000 μg/ml), acenaphthylene (1000 μg/ml),anthracene (1000 μg/ml), benz(a)anthracene (500 μg/ml), benzo(a)pyrene (500 μg/ml), benzo(b)fluoranthene (500 μg/ml)
benzo(k)fluoranthene (500 μg/ml), benzo(ghi)perylene (500 μg/ml), chrysene (500 μg/ml), dibenz(a,h)anthracene (500 μg/ml), fluoranthene (500 μg/ml), fluorene (1000 μg/ml), indeno(1,2,3-cd)pyrene (500 μg/ml), naphthalene (1000 μg/ml), phenanthrene (500 μg/ml), pyrene (500 μg/ml).

Expand 1 Items
 
Phenol

Phenol

Supplier: Restek

Organic Standard, Phenol, 1 ml/ampoule

Expand 1 Items
 
VOA purgeable halocarbon mix #1 (23 components)

VOA purgeable halocarbon mix #1 (23 components)

Supplier: Restek

Mix contains: Bromodichloromethane (75-27-4); Bromoform (75-25-2); Carbon tetrachloride (56-23-5); Chlorobenzene (108-90-7); 2-Chloroethyl vinyl ether (110-75-8); Chloroform (67-66-3); Dibromochloromethane (124-48-1); 1,2-Dichlorobenzene (95-50-1); 1,3-Dichlorobenzene (541-73-1); 1,4-Dichlorobenzene (106-46-7); 1,1-Dichloroethane (75-34-3); 1,2-Dichloroethane (107-06-2); 1,1-Dichloroethene (75-35-4); trans-1,2-Dichloroethene (156-60-5); 1,2-Dichloropropane (78-87-5); cis-1,3-Dichloropropene (10061-01-5); trans-1,3-Dichloropropene (10061-02-6); Methylene chloride (dichloromethane) (75-09-2); 1,1,2,2-Tetrachloroethane (79-34-5); Tetrachloroethene (127-18-4); 1,1,1-Trichloroethane (71-55-6); 1,1,2-Trichloroethane (79-00-5); Trichloroethene (79-01-6).

Expand 1 Items
 
Capillary columns, Rtx®-VMS (fused silica)

Capillary columns, Rtx®-VMS (fused silica)

Supplier: Restek

Proprietary Crossbond® phase, specific columns for volatile organic compounds.

Expand 13 Items
 
Reference standards for food analysis

Reference standards for food analysis

Supplier: Restek

FAME mix, for food industry (37 components)

Expand 33 Items
 
Ethylene oxide

Ethylene oxide

Supplier: Restek

The test for ethylene oxide is specified in many individual drug monographs of USP24/NF19. The limit test concentration is currently 10 ppm. While the specific test solution and method will vary depending on the particular drug monograph, the solution below is suitable for most tests.

Expand 2 Items
 

HPLC columns, Allure® C18 (USP L1)

Supplier: Restek

Allure® C18 columns are designed using a unique bonding chemistry that offers resistance to hydrolysis and superior batch to batch reproducibility. The high carbon load phase exhibits maximum retention characteristics, making it ideal for liquid chromatography/mass spectrometry (LC/MS) applications. The phase is bonded onto a highly base deactivated type B silica, resulting in improved peak symmetry, even for basic analytes. The column can be used to analyse compounds, steroids, antibiotics and explosives.

Expand 10 Items
 

HPLC columns, Ultra PFP (USP L43)

Supplier: Restek

Ultra PFP columns are with a pentafluorophenyl phase and has unique selectivity for compounds containing organohalogens or other basic functional groups.

Expand 14 Items
 
UHPLC columns, Pinnacle® DB Cyano (USP L10)

UHPLC columns, Pinnacle® DB Cyano (USP L10)

Supplier: Restek

Highly base-deactivated spherical silica manufactured by Restek. Cyano bonding. Suitable for analyses of a wide range of compounds, from acidic through slightly basic. Also useful for confirmation of analyses on a C18 or C8 column. Can be used in normal phase or reversed phase mode of separation.

Expand 71 Items
 
Luer lock valve adaptors

Luer lock valve adaptors

Supplier: Restek

These Luer lock valve adaptors are suitable for connecting a Luer lock fitting to a Rheodyne or Valco valve.

Expand 1 Items
 
FID collector assembly kit

FID collector assembly kit

Supplier: Restek

These FID collector assembly kits are made of high-quality stainless steel. Ideal for Agilent 5890/6850/6890/7890 GCs.

Expand 10 Items
 
Installation kits for packed columns

Installation kits for packed columns

Supplier: Restek

Installation Kit for 2 mm ID columns; for valve applications, Kit contains 1× stainless steel nut 3,2 mm, 1× stainless steel Valco nut, 1× Vespel/graphite ferrule 3,2 mm, 1× stainless steel Valco ferrule 3,2 mm, 1× stainless steel front ferrule 3,2 mm, 1× stainless steel back ferrule 3,2 mm

Expand 1 Items
 
Sort By
Recommended for You