Order Entry
Denmark
Orders LinkContactUsLinkComponent
Multi-parameter meter (pH/conductivity), bench, 3540

Multi-parameter meter (pH/conductivity), bench, 3540

Supplier:   Cole-Parmer
Multi-parameter meter (pH/conductivity), bench, 3540
Supplier:  Cole-Parmer
Certificates
Multi-parameter meter (pH/conductivity), bench, 3540
Multi-parameter meter (pH/conductivity), bench, 3540

1 Options Available Below

Product Details & Documents

Ideal for use in all laboratories where pH and conductivity analyses are required.

  • Simultaneous display of pH and conductivity
  • Two independent channels to prevent interference between probes
  • Additional modes for resistivity, salinity, TDS and mV
  • Data logger with auto save/print options
  • Storage of up to 500 readings (250 for each mode)

Ordering information: Supplied with glass combination pH electrode 662-0343, glass conductivity probe (K=1, 663-0005), electrode stand and holder, ATC probe 662-0338, BNC shorting plug, pH buffers and power supply.

Specifications for Product Family

Specifications

  • Catalog No:
  • 662-0331
  • JENW79000-58
  • Model:
  • 3540
  • 3540
  • pH range:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH resolution:
  • 0,001 / 0,01 / 0,1 selectable
  • 0,001 / 0,01 / 0,1 selectable
  • pH accuracy:
  • ±0,003
  • ±0,003
  • pH calibration:
  • Automatic, 1, 2 or 3-point
    Auto. buffer recognition: Jenway, NIST, DIN and JIS
  • Automatic, 1, 2 or 3-point
    Auto. buffer recognition: Jenway, NIST, DIN and JIS
  • mV range:
  • ±1999,9
  • ±1999,9
  • mV resolution:
  • 0,1
  • 0,1
  • mV accuracy:
  • ±0,2
  • ±0,2
  • Conductivity range:
  • Auto–selected from 0,01 µS to 1999 mS/cm
  • Auto–selected from 0,01 µS to 1999 mS/cm
  • Conductivity resolution:
  • 0,01 µS to 1 mS
  • 0,01 µS to 1 mS
  • Conductivity accuracy:
  • ±0,5% ±2 digits
  • ±0,5% ±2 digits
  • Conductivity cell constant:
  • 0,010 - 19,999 cm⁻¹
  • 0,010 - 19,999 cm⁻¹
  • Conductivity calibration:
  • Automatic, 1, 2 or 3 points
    Automatic standard recognition: 10 µS, 84 µS, 1413 µS, 12,88 mS (with manual override)
  • Automatic, 1, 2 or 3 points
    Automatic standard recognition: 10 µS, 84 µS, 1413 µS, 12,88 mS (with manual override)
  • Temperature range:
  • –10...+105 °C
  • –10...+105 °C
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,5 °C
  • ±0,5 °C
  • Temperature compensation:
  • ATC and manual, 0...+100 °C
  • ATC and manual, 0...+100 °C
  • Display:
  • Backlit 1/8 VGA LCD
  • Backlit 1/8 VGA LCD
  • Compliance:
  • GLP
  • GLP
  • Data logging capacity:
  • Up to 500 readings (250 for each mode)
  • Up to 500 readings (250 for each mode)
  • Connections:
  • BNC (pH) and 7–pin DIN (conductivity)
  • BNC (pH) and 7–pin DIN (conductivity)
  • Outputs:
  • Analogue, RS232 and IrDA interface
  • Analogue, RS232 and IrDA interface
  • W×D×H:
  • 210×250×55 mm
  • 210×250×55 mm
  • Weight:
  • 0,850 kg
  • 0,850 kg

Specifications

Product Family Options

Product Information

  • Availability
    Price
  • 662-0331
    Bench pH/conductivity meter 3540, UK-plug
    Bench pH/conductivity meter 3540, UK-plug
    Discontinued
    Specifications:
    More
    Specifications
    Cat. No.
    662-0331
    Model
    3540
    pH range
    –2,000...+20,000
    pH resolution
    0,001 / 0,01 / 0,1 selectable
    pH accuracy
    ±0,003
    pH calibration
    Automatic, 1, 2 or 3-point
    Auto. buffer recognition: Jenway, NIST, DIN and JIS
    mV range
    ±1999,9
    mV resolution
    0,1
    mV accuracy
    ±0,2
    Conductivity range
    Auto–selected from 0,01 µS to 1999 mS/cm
    Conductivity resolution
    0,01 µS to 1 mS
    Conductivity accuracy
    ±0,5% ±2 digits
    Conductivity cell constant
    0,010 - 19,999 cm⁻¹
    Conductivity calibration
    Automatic, 1, 2 or 3 points
    Automatic standard recognition: 10 µS, 84 µS, 1413 µS, 12,88 mS (with manual override)
    Temperature range
    –10...+105 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,5 °C
    Temperature compensation
    ATC and manual, 0...+100 °C
    Display
    Backlit 1/8 VGA LCD
    Compliance
    GLP
    Data logging capacity
    Up to 500 readings (250 for each mode)
    Connections
    BNC (pH) and 7–pin DIN (conductivity)
    Outputs
    Analogue, RS232 and IrDA interface
    W×D×H
    210×250×55 mm
    Weight
    0,850 kg
  • JENW79000-58
    Bench pH/conductivity meter 3540, EU-plug
    Bench pH/conductivity meter 3540, EU-plug
    Log in for availability
    Log in for availability
    1 * 1 Items
    1 * 1 Items - 12.040,00 kr
    12.040,00 kr
    1 * 1 Items
       12.040,00 kr

    Specifications:
    More
    Specifications
    Cat. No.
    JENW79000-58
    Model
    3540
    pH range
    –2,000...+20,000
    pH resolution
    0,001 / 0,01 / 0,1 selectable
    pH accuracy
    ±0,003
    pH calibration
    Automatic, 1, 2 or 3-point
    Auto. buffer recognition: Jenway, NIST, DIN and JIS
    mV range
    ±1999,9
    mV resolution
    0,1
    mV accuracy
    ±0,2
    Conductivity range
    Auto–selected from 0,01 µS to 1999 mS/cm
    Conductivity resolution
    0,01 µS to 1 mS
    Conductivity accuracy
    ±0,5% ±2 digits
    Conductivity cell constant
    0,010 - 19,999 cm⁻¹
    Conductivity calibration
    Automatic, 1, 2 or 3 points
    Automatic standard recognition: 10 µS, 84 µS, 1413 µS, 12,88 mS (with manual override)
    Temperature range
    –10...+105 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,5 °C
    Temperature compensation
    ATC and manual, 0...+100 °C
    Display
    Backlit 1/8 VGA LCD
    Compliance
    GLP
    Data logging capacity
    Up to 500 readings (250 for each mode)
    Connections
    BNC (pH) and 7–pin DIN (conductivity)
    Outputs
    Analogue, RS232 and IrDA interface
    W×D×H
    210×250×55 mm
    Weight
    0,850 kg