You searched for: Chromatography Standards
Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.
Poly(2-vinylpyridine), analytical standards, Supelco®
Supplier: Merck
GPC Standard, Mw 37,500 (Typical), Supelco®, Glass bottle
Expand 3 Items
Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), Supelco®, 25 wt. % in toluene, Analytical standard
Expand 1 Items
Poly(ethylene glycol) analytical standards, for GPC, Supelco
Supplier: Merck
Poly(ethylene glycol) is the most widely used non-ionic, hydrophilic polymer, which can find wide applications in biomedical industry such as in drug delivery systems.
Expand 1 Items
Reversed phase test mix, in methanol: water (3:2) (varied conc.), certified reference material, Supelco®
Supplier: Merck
HPLC Standard, Reversed Phase Test Mix, in methanol: water (3:2) (varied conc.), TraceCERT®, Supelco®, Certified reference material, Pk Info: ampule of 1 mL
Expand 1 Items
Poly(Bisphenol A carbonate), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(Bisphenol A carbonate), Supelco®, Analytical standard
Expand 1 Items
HPLC isocratic systems diagnostics mix, in methanol: water (3:2) (varied concentration), certified reference material, Supelco®
Supplier: Merck
This formulation is designed for evaluating how reliably a chromatographic system is providing such fundamentally important parameters as flow rate, proportioning, and mixing.
Expand 1 Items
Poly(methacrylic acid sodium salt) analytical standards, for GPC, Supelco®
Supplier: Merck
GPC Standard, ~18600,Mw, Mw/Mn <1,20, Supelco®
Expand 3 Items
Polystyrene, analytical standards for GPC
Supplier: Merck
GPC Standard, Mw 2000000 (typical), Supelco®
Expand 23 Items
Test mixture 2 for apolar capillary columns according to Grob, for GC
Supplier: Merck
Standard for GC, Test mixture 2 for apolar capillary columns according to Grob, Supelco®, ready-to-use
Expand 1 Items
Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), Supelco®, Analytical standard
Expand 1 Items
Reversed phase test mix 2, certified reference material, Supelco®
Supplier: Merck
HPLC Standard, Reversed Phase Test Mix 2, TraceCERT®, Supelco®, in acetonitrile: water (varied conc.) solution, Certified reference material, Pk Info: ampule of 1 mL
Expand 1 Items
Poly(α-methylstyrene) analytical standards, for GPC
Supplier: Merck
Poly(α-methylstyrene) may find applications as a radical producing agent, in the thermal degradation of polystyrene.
Expand 3 Items
Polyethylene analytical standards, for GPC
Supplier: Merck
GPC Standard, ∼2010 Mw, Mw/Mn ~1,12, Supelco®
Expand 1 Items
Dimethylpolysiloxane set of analytical standards, molecular weight series
Supplier: Merck
Clear, colorless fluid polymer useful as a stationary phase in gas chromatography and as an anti-foaming agent.
Expand 1 Items
Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), Supelco®, Analytical standard
Expand 1 Items
Poly(methyl methacrylate) PMMA, analytical standard, for GPC
Supplier: Merck
Poly(methyl methacrylate) is a rigid and transparent type of polymer material. It is obtained via polymerization of methyl methacrylate monomer.
Expand 10 Items
Poly(dimethylsiloxane), average Mw 95000 (Typical), average Mn 50000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(dimethylsiloxane), average Mw 95000 (Typical), average Mn 50000 (Typical), Supelco®, Analytical standard
Expand 1 Items
Poly(styrenesulfonic acid sodium salt) analytical standards for GPC
Supplier: Merck
GPC Standard, ~10600 Mw, Mw/Mn ≤1,20, Supelco®
Expand 9 Items
Poly(butylmethacrylate), analytical standard, for GPC
Supplier: Merck
GPC Standard, ∼682000 Mn, Mw/Mn ~1,06, Supelco®
Expand 1 Items
Poly(acrylic acid), average Mn 130000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(acrylic acid), average Mn 130000 (Typical), Supelco®, Analytical standard
Expand 1 Items
HPLC standards, LiChroTest®, Supelco®
Supplier: Merck
Standard samples for HPLC System Qualification.
Expand 6 Items
Nucleosides test mix, analytical standard, Supelco®
Supplier: Merck
HPLC Standard, Nucleosides Test Mix, Supelco®, in 1% sodium formate (varied conc.), Analytical standard, Pk Info: ampule of 1 mL
Expand 1 Items
Polystyrene standard ReadyCal set Mp 400-2000000, analytical standards for GPC
Supplier: Merck
Set contains 12 different polystyrene standards with Mp ~374, ~1620, ~3420, ~9130, ~18100, ~32500, ~67500, ~128000, ~246000, ~659000, ~1000000, ~2180000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations.
Expand 1 Items
Peptide and protein MALDI-MS calibration kit, ProteoMass™, Supelco®
Supplier: Merck
This kit features a convenient selection of pre-qualified standard peptides, proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionisation (MALDI) mass spectrometers.
Expand 1 Items
Polyethylene glycol Standard ReadyCal Set Mp 200-1200000, for GPC, Supelco
Supplier: Merck
Set contains 10 different polyethylene glycol/polyethylene oxide standards with Mp ~194, ~970, ~2010, ~4450, ~15000, ~22100, ~62000, ~217000, ~490000, ~1190000; always 3 or 4 standards are lyophilised in a 1,5 ml vial (black, blue or yellow); for 1 complete calibration use one of each of the black, blue and yellow vials; 1 set contains 30 vials for 10 complete calibrations.
Expand 1 Items
VWR® PESTINORM®, Dichloromethane (DCM) Stabilised, Secondary Reference Standard for GC
Supplier: VWR Chemicals
A secondary GC solvent reference standard for various chromatographic and analytical applications.
Expand 1 Items
Poly(butyl acrylate) solution, Mw 60000 (Typical), average Mn 20000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(butyl acrylate) solution, Mw 60000 (Typical), average Mn 20000 (Typical), Supelco®, 25 wt. % in toluene, Analytical standard
Expand 1 Items
Poly(Bisphenol A carbonate) analytical standards kit, molecular weight series, for GPC
Supplier: Merck
Poly(Bisphenol A carbonate) (PC) is a thermoplastic material. It is injected in molding operations and is majorly studied to understand its thermal behaviour, especially thermal degradation property.
Expand 1 Items
Polyethylene glycol Standard ReadyCal Set Mp 102-40′000, for GPC
Supplier: Merck
Set contains 12 different polyethyleneglycol standards with Mp ~106, ~330, ~420, ~600, ~1500, ~2010, ~3120, ~6240, ~8600, ~12000, ~23000, ~40000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations
Expand 1 Items
VWR® PESTINORM®, Gas Chromatography (GC) Certified Reference Material
Supplier: VWR Chemicals
Due to its excellent separation capacity and its high sensitivity gas chromatography is a widely used technique for analytical purposes. In order to get proper identification and quantification results of the analysed compounds, reference standards are needed. These PESTINORM® reference substances can be used for the characterisation of GC column properties. In addition they may also be used for the identification of unknown compounds in a gas chromatogram or as standards in quantitative GC analysis.