You searched for: Chromatography Standards
Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.
Calibration standards for size exclusion chromatography
Supplier: Resonac
Size Exclusion Standard, Standard P-82, 0,2 g × 8 standards, with MW range 5000 - 800000, pullulan
Expand 5 Items
Mass spectrometry controls, peptide retention time calibration mixture, Pierce™
Supplier: Thermo Fisher Scientific
The Pierce mixture enables reversed phase liquid chromatography (LC) and mass spectrometry (LC-MS) users to optimise and confirm correct operation of their equipment.
Expand 2 Items
Polypropylene Glycol Standards
Supplier: AGILENT
Polypropylene glycol standard, PDI <1,15, 1 g.
Expand 5 Items
Molecular weight calibration standards for SEC
Supplier: TOSOH Bioscience
These standards consists of bulk quantities of polystyrene and polyethylene oxide standards of varying molar mass and pre-mixed quantities of polystyrene polymers for calibration of GPC columns.
Expand 25 Items
Organic standards for gas chromatography
Supplier: PerkinElmer
Standard for GC, Benzidines mix
Expand 31 Items
Standards solutions for HPLC
Supplier: PerkinElmer
HPLC Standard, Universal test mix for Reversed-phase, 5 ml
Expand 1 Items
Test mixtures for gas chromatography
Supplier: MACHEREY-NAGEL
These test mixtures are used for controlling the performance of fused silica capillary columns and the GC system.
Expand 8 Items
Polystyrene Test Film - MIR
Supplier: PerkinElmer
This test film is an easy-to-use standard to check frequency, accuracy and any changes.
Expand 1 Items
Calibration reference materials for autosamplers, Diamond™ DSC
Supplier: PerkinElmer
DSC Standard, Reference material, Alumel, Diamond™
Expand 8 Items
Standards for ion chromatograpghy
Supplier: CPACHEM
Standard for Liqid Chromatography, Monomethylamine 1000 mg/l in water
Expand 7 Items
LC OQ standards kit
Supplier: Restek
Standard for Liqid Chromatography, LC OQ standards kit (acetone)
Expand 1 Items
LC OQ standards kit
Supplier: Restek
Standard for Liqid Chromatography, LC OQ standards kit
Expand 1 Items
LC OQ wavelength accuracy standard
Supplier: Restek
Erbium perchlorate, 14017-55-1
Expand 1 Items
Standards and test mixes for liquid chromatography
Supplier: Restek
Linear detector responses to concentration variations are an important part of operation qualification (OQ) for LC instruments. Kit of five aqueous solutions of caffeine can be used to generate simple plots of UV response versus concentration.
Expand 6 Items
FID performance evaluation standard
Supplier: Restek
FID performance evaluation standard contains three components such as (C14) n-Tetradecane (629-59-4), (C15) n-Pentadecane (629-62-9) and (C16) n-Hexadecane (544-76-3).
Expand 1 Items
Standards for LC performance, test mix, CRM
Supplier: Restek
Highly effective for characterising LC column parameters and tested against the NIST 870 standard.
Expand 1 Items
Carbohydrate LC performance check mix (5 components)
Supplier: Restek
This carbohydrate LC performance check mix consist of five components which performance qualification (PQ) determines the precision of the LC system.
Expand 1 Items
QuEChERS quality control standards for GC-MS analysis
Supplier: Restek
Pesticide analysis is fast and simple using QuEChERS methods. Use these cost-effective QuEChERS standards for even greaterlab efficiency. Standards are compatible with all major methods, including mini-multiresidue, AOAC, and European procedures.
Expand 2 Items
Pre-weighted calibration kits, EasiVial™
Supplier: VARIAN
The quickest and most convenient method to deliver an accurate 12 point column calibration for organic and aqueous GPC/SEC column calibration.
Expand 18 Items
Calibration mixture, Connecticut ETPH
Supplier: Restek
Certified reference materials (CRMs) manufactured and QC-tested in ISO-accredited labs.
Expand 1 Items
MOSH/MOAH Retention Time Standard
Supplier: Restek
Developed specifically for using LC coupled with GC-FID to accurately determine hydrocarbons found in mineral oils, which can migrate from processing equipment and packaging into food.
Expand 1 Items
NPI-1000 column test mix (8 components)
Supplier: Restek
The mix consists of (C9:0) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, 1,6-hexanediol, 4-propylaniline and 1-undecanol.
Expand 1 Items
XERT-500 column test mix (8 components)
Supplier: Restek
This contains (C9:0 FAME) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, n-decylamine, 1,6-hexanediol and 1-undecanol (112-42-5).
Expand 1 Items
Test mix for NPI-350 column (8 components)
Supplier: Restek
This test mix for NPI-350 column contains: (C9:0 FAME) Methyl nonanoate (1731-84-6); (C13) n-Tridecane (629-50-5); (C15) n-Pentadecane (629-62-9); Acenaphthylene (208-96-8); 4-Chlorophenol (106-48-9); 1,6-Hexanediol (629-11-8); 4-Propylaniline (2696-84-6); 1-Undecanol (112-42-5).
Expand 1 Items
Amine column test mix (GC) (8 components)
Supplier: Restek
The amine column test mix consists of (C10) decane (0,60 mg/ml), (C12) dodecane (0.60 mg/ml, 1,2-butanediol (0.60 mg/ml), diethanolamine (DEA) (1.20 mg/ml), diethylenetriamine (1.20 mg/ml), 2,6-dimethylaniline (0.60 mg/ml), 2-nonanol (0.60 mg/ml), pyridine(0.60 mg/ml).
Expand 1 Items
Chiral column test mix (9 components)
Supplier: Restek
The mix consists of (C10:0) Methyl decanoate (210 μg/ml), (C11:0) methyl undecanoate (210 μg/ml), (C12) n-dodecane 150 μg/ml, (C12:0) methyl dodecanoate (210 μg/ml), 2,3-butanediol (+/-) (500 μg/ml), 1-heptanol (180 μg/ml), 3-methylphenol (m-cresol) (160 μg/ml), 1-phenylethanol (+/-) (500 μg/ml) and α-pinene (+/-) (500 μg/ml).
Expand 1 Items
Polystyrene film - IR transmission wavelength standards, NIST-1921B
Supplier: LGC Standards PROMOCHEM
NIST-1921B, Polystyrene film - IR transmission wavelength
Expand 1 Items
Positive electrophoretic mobility standard, NIST-1980
Supplier: LGC Standards PROMOCHEM
This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.
Expand 1 Items
Pre-prepared polystyrene kits, EasiCal™
Supplier: VARIAN
The EasiCal system for organic solvents consists of two different combs, each with ten detachable spatulas supporting a mixture of five polymer standards with MWs selected to provide equidistant calibration points for greater accuracy.
Expand 4 Items
Polystyrene standards, GPC/SEC columns calibration
Supplier: VARIAN
Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.