Order Entry
Denmark
ContactUsLinkComponent
31 results for Transfer Membranes

You searched for: Transfer Membranes

Transfer Membranes

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.

Sort By
Immobilon®-P Blotting Sandwich Transfer Membranes

Immobilon®-P Blotting Sandwich Transfer Membranes

Supplier: Merck

Immobilon®-P, Immobilon-P blotting sandwich transfer membranes, 7×8,4 cm

Expand 2 Items
Loading...
Biodyne® Nylon Transfer Membranes

Biodyne® Nylon Transfer Membranes

Supplier: Cytiva (Formerly Pall Lab)

Biodyne® Transfer Membranes offer high sensitivity and low background for enhanced detection and resolution. They are ideal for nucleic acid detection.

Expand 12 Items
Loading...
Millipore® Immobilon®-NC Hydrophilic Transfer Membrane

Millipore® Immobilon®-NC Hydrophilic Transfer Membrane

Supplier: Merck

Triton-free, mixed cellulose esters transfer membrane.

Expand 1 Items
Loading...
Millipore® Immobilon®-E NOW Bundle Hydrophobic PVDF Transfer Membrane

Millipore® Immobilon®-E NOW Bundle Hydrophobic PVDF Transfer Membrane

Supplier: Merck

The first PVDF transfer membrane for western blotting that wets out in transfer buffer or water. For chemiluminescence or chromogenic detection.

Expand 1 Items
Loading...
Millipore® Immobilon®-P NOW Bundle Hydrophobic PVDF Transfer Membrane

Millipore® Immobilon®-P NOW Bundle Hydrophobic PVDF Transfer Membrane

Supplier: Merck

Hydrophobic immobilon-P PVDF transfer membrane for western blotting using chemiluminescence, chromogenic or radioactive detection methods.

Expand 1 Items
Loading...
Millipore® Immobilon®-NC NOW Bundle Hydrophilic Mixed Cellulose Esters Transfer Membrane

Millipore® Immobilon®-NC NOW Bundle Hydrophilic Mixed Cellulose Esters Transfer Membrane

Supplier: Merck

Triton-free, mixed cellulose esters transfer membrane, includes 1 dispenser.

Expand 1 Items
Loading...
Millipore® Immobilon®-FL NOW Bundle Hydrophobic PVDF Transfer Membrane

Millipore® Immobilon®-FL NOW Bundle Hydrophobic PVDF Transfer Membrane

Supplier: Merck

Hydrophobic PVDF transfer membrane for western blotting using fluorescent, chemifluorescence, chromogenic, or chemiluminescence.

Expand 1 Items
Loading...
Millipore® Immobilon® PVDF Transfer Membranes

Millipore® Immobilon® PVDF Transfer Membranes

Supplier: Merck

These Immobilon® PVDF membranes, each optimised for different protein blotting applications.

Expand 25 Items
Loading...
Millipore® Immobilon®-PSQ NOW Bundle Hydrophobic PVDF Transfer Membrane

Millipore® Immobilon®-PSQ NOW Bundle Hydrophobic PVDF Transfer Membrane

Supplier: Merck

PVDF transfer membrane hydrophobic for western blotting using chemiluminescence, chromogenic or radioactive detection methods.

Expand 1 Items
Loading...
Millipore® Immobilon®-NC Nitrocellulose Transfer Membranes

Millipore® Immobilon®-NC Nitrocellulose Transfer Membranes

Supplier: Merck

Immobilon-NC (HATF) membrane is composed of a mixed cellulose esters matrix. It is devoid of surfactants that may interfere with cell wall integrity during cell growth

Expand 2 Items
Loading...
Transfer membranes, PVDF, Pierce™

Transfer membranes, PVDF, Pierce™

Supplier: Thermo Fisher Scientific

Transfer membranes made of high quality PVDF, which provides high binding capacity for proteins and nucleic acids.

Expand 4 Items
Loading...
Transfer membranes, PVDF, Owl™, Immobilon-P™

Transfer membranes, PVDF, Owl™, Immobilon-P™

Supplier: THERMO OWL SCIENTIFIC

Hydrophobic polyvinylidene fluoride transfer membrane has a high signal-to-noise ratio, which allows for the use of mild blocking procedures

Expand 3 Items
Loading...
FluoroTrans® PVDF Transfer Membranes

FluoroTrans® PVDF Transfer Membranes

Supplier: Cytiva (Formerly Pall Lab)

Naturally hydrophobic PVDF, ideal for a wide variety of protein-analysis applications. The family of FluroTrans® media are white, microporous solid phase supports that bind proteins tenaciously via hydrophobic interactions. FluoroTrans® membrane is optimised for N-terminal protein sequencing. FluoroTrans® W membranes are optimised for Western transfer applications. They allow for sensitive protein detection with low background and very low protein burn-through. Immobilised proteins can be visually detected with Coomassie® Blue, Amido black, Ponceau S, and colloidal gold.

Expand 8 Items
Loading...
Blotting membranes, nitrocellulose

Blotting membranes, nitrocellulose

Supplier: Thermo Fisher Scientific

Nitrocellulose membranes are a popular matrix used in protein blotting because of their high protein-binding affinity, compatibility with a variety of detection methods (chemiluminescence, chromogenic, and fluorescence), and the ability to immobilise proteins, glycoproteins, or nucleic acids. Protein immobilisation is thought to occur by hydrophobic interactions, and high salt and low methanol concentrations help improve protein immobilisation to the membrane during electrophoretic transfer, especially for proteins with higher molecular weights. Nitrocellulose membranes are not optimal for electrophoretic transfer of nucleic acids, as the high salt concentrations that are required for efficient binding will effectively elute some or all of the charged nucleic acid fragments.

Expand 7 Items
Loading...

Blotting membranes, nylon, Biodyne™ B

Supplier: Thermo Fisher Scientific

Biodyne™ B nylon membranes are sheets of positively charged nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ B nylon membrane is manufactured with a matrix pore size of 0,4 micron. It contains exclusively positive charges, providing the highest possible binding capacity for negatively charged molecules, like DNA and RNA.

Expand 1 Items
Loading...
Pierce™, Biodyne™ A Blotting Membranes, Nylon

Pierce™, Biodyne™ A Blotting Membranes, Nylon

Supplier: Thermo Fisher Scientific

Biodyne™ A nylon membranes are sheets of unmodified nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ A nylon membrane is manufactured with a matrix pore size of 0,45 micron. It contains both negatively and positively charged groups, enabling it to bind many kinds of macromolecules.

Expand 1 Items
Loading...
Membranes and padding for Western protein transfers, pre-cut

Membranes and padding for Western protein transfers, pre-cut

Supplier: G-Biosciences

Pre-cut transfer membranes and padding for Western blot transfer procedures. Pre-cut membranes are supplied sandwiched between blotting paper padding. Simply soak the membrane in transfer buffer and assemble with the gel in a transfer cassette. Nitrocellulose (0,22 µm pore size) and PVDF (0,45 µm pore size) membranes are available.

Expand 3 Items
Loading...
Whatman™ Protran® BA85 & BA83 NC Western Blotting Membranes, Nitrocellulose

Whatman™ Protran® BA85 & BA83 NC Western Blotting Membranes, Nitrocellulose

Supplier: Whatman products (Cytiva)

Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pre treatment steps are necessary.

Expand 6 Items
Loading...
Blotting membranes, Nytran® N, Whatman™

Blotting membranes, Nytran® N, Whatman™

Supplier: Whatman products (Cytiva)

The Nytran® Nylon (Nytran® N) membrane is ideal for applications that require a lower charge. It is designed for Southern and Northern blotting as well as colony and plaque lifts and Dot or Slot Blots. Nytran® N is compatible with isotopic detection methods.

Expand 2 Items
Loading...
Blotting membranes, Nytran® SuPerCharge, Whatman™

Blotting membranes, Nytran® SuPerCharge, Whatman™

Supplier: Whatman products (Cytiva)

Nytran® SuPerCharge (SPC) nylon membranes have a very high positive charge and a higher density of nylon per unit area. Available as circles, sheets or rolls for microplates.

Expand 3 Items
Loading...
Amersham™ Protran® Premium Western Blotting Membranes, Nitrocellulose

Amersham™ Protran® Premium Western Blotting Membranes, Nitrocellulose

Supplier: Cytiva

Amersham™ Protran® Premium nitrocellulose blotting membranes provide excellent sensitivity, resolution and low background in fluorescence Western blotting detection applications.

Expand 15 Items
Loading...
Blotting membranes, Amersham™ Hybond™-N+

Blotting membranes, Amersham™ Hybond™-N+

Supplier: Cytiva

Amersham™ Hybond™-N+ is a positively charged nylon membrane with a binding capacity for nucleic acids up to 600 µg/cm² recommended for use with radioactive or non radioactive chemiluminescence and chemifluorescence detection systems.

Expand 8 Items
Loading...
Blotting membranes, Amersham™ Hybond™ SEQ 0,2 PVDF

Blotting membranes, Amersham™ Hybond™ SEQ 0,2 PVDF

Supplier: Cytiva

Amersham™ Hybond™ SEQ 0.2 PVDF is a 0,2 µm pore size hydrophobic membrane designed specifically for protein sequencing applications. The small pore size of this membrane minimises ‘blow-through’ and increases protein binding over a wide range of molecular weights.

Expand 1 Items
Loading...
Blotting membranes, Amersham™ Hybond™ 0.2 PVDF

Blotting membranes, Amersham™ Hybond™ 0.2 PVDF

Supplier: Cytiva

Amersham™ Hybond™ 0.2 PVDF is a 0,2 μm pore size hydrophobic membrane with high physical strength. This results in significant handling advantages over unsupported nitrocellulose and makes the membrane highly suitable for stripping and reprobing. The small pore size of the membrane minimises 'blow-through' and increases protein binding over a wide range of molecular weights. Ideal for use with standard colorimetric and chemiluminescent detection methods for proteins of

Expand 5 Items
Loading...
Blotting membranes, Amersham™ Hybond™ LFP 0,2 PVDF

Blotting membranes, Amersham™ Hybond™ LFP 0,2 PVDF

Supplier: Cytiva

Amersham™ Hybond™ LFP 0.2 PVDF is a low fluorescent, hydrophobic membrane, with 0,2 µm pore size, for protein transfer. Amersham™ Hybond™ LFP is optimised for fluorescent detection in Western blotting applications and for use with the Amersham™ ECL Plex™ detection system.

Expand 4 Items
Loading...
Blotting membranes, Amersham™ Hybond™ ECL™

Blotting membranes, Amersham™ Hybond™ ECL™

Supplier: Cytiva

Hybond™ ECL™ gives excellent sensitivity, resolution, and low background for all labelling and detection systems (radioactive, non radioactive, and chromogenic), especially when used with ECL™, ECL™ Prime, and ECL™ Plex Western Blotting Detection kits and reagents. Special packaging features include interleaf on both sides of the membrane and air-tight resealable aluminium bag with label space for marking the 'opened on' date.

Expand 2 Items
Loading...
Blotting membranes, Amersham™ Hybond™ 0,45 PVDF

Blotting membranes, Amersham™ Hybond™ 0,45 PVDF

Supplier: Cytiva

Amersham™ Hybond™ P 0,45 PVDF is a 0,45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing. For use in chemiluminescent and fluorescent detection methods for proteins of >Mr 20000.

Expand 8 Items
Loading...
Amersham™ Protran® Supported Nitrocellulose Western Blotting Membranes, Cytiva

Amersham™ Protran® Supported Nitrocellulose Western Blotting Membranes, Cytiva

Supplier: Cytiva

Amersham™ Protran® Supported is a robust protein blotting membrane, with 0,2 µm pore size, made of reinforced nitrocellulose for multiple reprobings.

Expand 11 Items
Loading...
Amersham™ Protran® Western Blotting Membranes, Nitrocellulose

Amersham™ Protran® Western Blotting Membranes, Nitrocellulose

Supplier: Cytiva

Amersham™ Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pretreatment steps are necessary.

Expand 26 Items
Loading...
Blotting membrane, nitrocellulose

Blotting membrane, nitrocellulose

Supplier: Sartorius

These nitrocellulose blotting membranes are ideal for Western blotting, DNA blotting, as well as dot or slot blots. They are optimally adapted to all protein blotting systems, such as electro transfer, semi-dry or simple capillary blotting. A high protein binding capacity is combined with low background to give good blocking possibilities. High membrane stability ensures easy handling of the blotting membrane, even when wet.

Expand 1 Items
Loading...
Sort By
Recommended for You