"Solid Phase Extraction"
Supelco® TraceCERT® Organic Reference Standard, Metrafenone
Supplier: Merck
Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).
Expand 1 Items
Solid phase extraction cartridges, HyperSep™ SAX
Supplier: Thermo Fisher Scientific
Strong anion exchange sorbent for extraction of weak acids.
Expand 9 Items
SPE plates, 96-well, HyperSep™, Retain-AX
Supplier: Thermo Fisher Scientific
HyperSep Retain-AX is a high purity, highly porous polystyrene DVB material partially modified with quaternary functional groups to retain acidic analytes. The problems associated with column drying in traditional silica-based SPE materials are eliminated when using this product.
Expand 1 Items
Solid phase extraction cartridges, HyperSep™ SCX
Supplier: Thermo Fisher Scientific
A strong cation exchange sorbent for extraction of charged basic compounds.
Expand 10 Items
Solid phase extraction disks, Resprep® Oil & Grease
Supplier: Restek
Glass fiber disks embedded with specialty bonded silica. These disks reduce the emulsion formation and amount of solvent required by EPA methods. No chlorofluorocarbons needed.
Expand 1 Items
SPE microelution plates, SOLAµ™
Supplier: Thermo Fisher Scientific
SOLA™μ 96 well SPE micro elution plates are specifically designed to meet the increasingly demanding challenges found within bioanalysis. The micro elution format is uniquely positioned to deliver on bioanalytical needs, but limitations with existing
technological design has prevented significant uptake. The SOLA™μ product eliminates these issues by utilising SOLA technology, which removes the need for frits to retain the sorbent material and, in combination with a macro porous structure, allows for a robust, easily controllable platform for reproducible processing of bioanalytical samples.
Expand 5 Items
Solid phase extraction cartridges, HyperSep™ Aminopropyl
Supplier: Thermo Fisher Scientific
A polar sorbent for both polar and anion exchange interactions.
Expand 9 Items
SPE plates, 96-well, HyperSep™ C8
Supplier: Thermo Fisher Scientific
HyperSep C8 SPE Well Plates and Individual Wells provide excellent performance characteristics for moderately polar analytes. They also offer the potential for polar interactions greater than with C18.
Expand 4 Items
Micro extraction by packed sorbent (MEPS™)
Supplier: Trajan Scientific and Medical
Micro Extraction by Packed Sorbent (MEPS™) is a new development in the field of sample preparation by SPE (solid phase extraction). The MEPS™ product consists of two parts, the MEPS™ syringe and the MEPS™ Barrel Insert and Needle assembly (BIN). The MEPS™ approach to sample preparation is suitable for reversed phases, normal phases, mixed mode and ion exchange chemistries. Because MEPS™ BINs can be used for sample volumes as small as 10 µl it makes them particularly well suited to on-line use with LC-MS analysis of volume limited samples.
Expand 7 Items
SPE plates, 96-well, HyperSep™, C18
Supplier: Thermo Fisher Scientific
Thermo Scientific HyperSep™ C18 SPE 96-well plates and individual wells feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds. The hydrophobic reversed phase material is retentive for most nonpolar compounds, and retains most organic analytes from aqueous matrices.
Expand 5 Items
Solid phase extraction cartridges, HyperSep™ C8
Supplier: Thermo Fisher Scientific
HyperSep™ C8 cartridges, less retentive alternative to C18 for polar and nonpolar compounds.
Expand 8 Items
Flash cartridges, Mega Bond Elut™
Supplier: VARIAN
Flash cartridges for the purification of organic compounds, and also for scale-up, solid phase extraction.
Expand 24 Items
Solid phase extraction cartridges, HyperSep™ C18
Supplier: Thermo Fisher Scientific
These columns feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds.
Expand 12 Items
Solid phase extraction cartridges, Bond Elut™ CN-E
Supplier: VARIAN
A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.
Expand 4 Items
Solid phase extraction cartridges, Resprep®, C18 / C8
Supplier: Restek
These cartridges are made of glass fiber disks embedded with C18 or C8 bonded silica. These hydrophobic (nonpolar) silica-based adsorbents are ideal to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water).
Expand 9 Items
Sample delivery system, Resprep®
Supplier: Restek
This sample delivery system is used to transfer large volumes of low viscosity samples directly from a bottle to a solid phase extraction cartridge or to a disk on a vacuum manifold system for extraction or cleanup.
Expand 1 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".