Multi channel data loggers for pH, conductivity and temperature
Om denne vare
Multi-parameter data-logger is a configurable large measurement channel arrays like pH/mV/Ion, conductivity, oxygen and temperature.
- Multichannel up to 448 measurements can be performed at the same time and simultaneous displayed on the screen
- No interference between pH/ORP/Ion and conductivity electrodes in the same solution
- Free data acquisition software to control, collect and store data of a D230 system
- Data-logging can start/stop automatically or at a programmable date/time
- All data is saved in a user defined file in CSV format
- Graphs are generated using automatic or user defined settings
- Password protected
The system is based upon a D230 rack and 2 different measurement modules. Both modules can be used in the D230 system so you can configure a D230 as you wish. 16 fully loaded D230 racks connected to each other the complete D230 system can measure up to 448 channels.
The software automatically detects the maximum number and type of available channels. Data is collected on-line at a programmable interval determined by the program.
Table Data is always stored in a table. Each module has its own programmable table containing an unlimited number of lines. Comments can easily be added to each line in a special information column.
2 tilgængelige muligheder nedenfor
Product Details & Documents
Multi-parameter data-logger is a configurable large measurement channel arrays like pH/mV/Ion, conductivity, oxygen and temperature.
- Multichannel up to 448 measurements can be performed at the same time and simultaneous displayed on the screen
- No interference between pH/ORP/Ion and conductivity electrodes in the same solution
- Free data acquisition software to control, collect and store data of a D230 system
- Data-logging can start/stop automatically or at a programmable date/time
- All data is saved in a user defined file in CSV format
- Graphs are generated using automatic or user defined settings
- Password protected
The system is based upon a D230 rack and 2 different measurement modules. Both modules can be used in the D230 system so you can configure a D230 as you wish. 16 fully loaded D230 racks connected to each other the complete D230 system can measure up to 448 channels.
The software automatically detects the maximum number and type of available channels. Data is collected on-line at a programmable interval determined by the program.
Table Data is always stored in a table. Each module has its own programmable table containing an unlimited number of lines. Comments can easily be added to each line in a special information column.
Specifications for Product Family
Specifikationer
- Catalog No:
- CONSD230-CH
- CONSD230
- CONSD230-UK
- CONSD292
- Grænseflade:
- RS232
- RS232
- RS232
- RS232
- Registreringsintervaller:
- 4 s - 24 h
- 4 s - 24 h
- 4 s - 24 h
- 4 s - 24 h
- Vægt:
- 12 kg
- 12 kg
- 12 kg
- 12 kg
- B×D×H:
- 480×250×130 mm
- 480×250×130 mm
- 480×250×130 mm
- 480×250×130 mm
- Spænding:
- 210 - 250 V
- 210 - 250 V
- 210 - 250 V
- 210 - 250 V
Specifikationer
Product Family Options
Produktinformation
- OmrådeNøjagtighedOpløsningTilgængelighedPrice
- CONSD230-CHTil syv moduler, med software, RS232-kabel og strømkabel, CH-stikTil syv moduler, med software, RS232-kabel og strømkabel, CH-stikpH: 0 - 14
mV: ±2000
Ion: 0,01 ng/l - 100 mg/l
Dissolved oxygen: 0 - 60 mg/l
Conductivity: 0 - 2000 mS/cm
TDS: 0 - 100 g/l
T: –5...+105 °C±0,1 % ±1 cifret pH
±0,1 % ±1 cifret mV
±0,5 % ±1 cifret ion
1 % ±1 cifret opløst ilt
0,5 % f.s. af områdets konduktivitet
0,3 °CpH: 0,001
mV: 0,1
Eisen: dreistellig
Sauerstoffsättigung: 0,01 mg/l (0,1%)
Leitfähigkeit: 0,001 μS/cm
TDS: 0,01 mg/l
T: 0,1 °CDiscontinued-Specifikationer:More
Specifications
Cat. No.CONSD230-CHGrænsefladeRS232Registreringsintervaller4 s - 24 hVægt12 kgB×D×H480×250×130 mmSpænding210 - 250 V - CONSD230Til syv moduler, med software, RS232-kabel og strømkabel, EU-stikTil syv moduler, med software, RS232-kabel og strømkabel, EU-stikpH: 0 - 14
mV: ±2000
Ion: 0,01 ng/l - 100 mg/l
Dissolved oxygen: 0 - 60 mg/l
Conductivity: 0 - 2000 mS/cm
TDS: 0 - 100 g/l
T: –5...+105 °C±0,1 % ±1 cifret pH
±0,1 % ±1 cifret mV
±0,5 % ±1 cifret ion
1 % ±1 cifret opløst ilt
0,5 % f.s. af områdets konduktivitet
0,3 °CpH: 0,001
mV: 0,1
Eisen: dreistellig
Sauerstoffsättigung: 0,01 mg/l (0,1%)
Leitfähigkeit: 0,001 μS/cm
TDS: 0,01 mg/l
T: 0,1 °CLog ind for tilgængelighed1 * 1 Items26.010,00 krSpecifikationer:More
Specifications
Cat. No.CONSD230GrænsefladeRS232Registreringsintervaller4 s - 24 hVægt12 kgB×D×H480×250×130 mmSpænding210 - 250 V - CONSD230-UKTil syv moduler, med software, RS232-kabel og strømkabel, UK-stikTil syv moduler, med software, RS232-kabel og strømkabel, UK-stikpH: 0 - 14
mV: ±2000
Ion: 0,01 ng/l - 100 mg/l
Dissolved oxygen: 0 - 60 mg/l
Conductivity: 0 - 2000 mS/cm
TDS: 0 - 100 g/l
T: –5...+105 °C±0,1 % ±1 cifret pH
±0,1 % ±1 cifret mV
±0,5 % ±1 cifret ion
1 % ±1 cifret opløst ilt
0,5 % f.s. af områdets konduktivitet
0,3 °CpH: 0,001
mV: 0,1
Eisen: dreistellig
Sauerstoffsättigung: 0,01 mg/l (0,1%)
Leitfähigkeit: 0,001 μS/cm
TDS: 0,01 mg/l
T: 0,1 °CDiscontinued-Specifikationer:More
Specifications
Cat. No.CONSD230-UKGrænsefladeRS232Registreringsintervaller4 s - 24 hVægt12 kgB×D×H480×250×130 mmSpænding210 - 250 V - CONSD292Til konduktivitet/TDS/°C, otte kanalerTil konduktivitet/TDS/°C, otte kanalerConductivity: 0 - 2000 mS/cm
TDS: 0 - 100 g/l0,5 % f.s. af områdets konduktivitet; 0,3 °CLeitfähigkeit: 0,001 μS/cm
TDS: 0,01 mg/l
T: 0,1 °CLog ind for tilgængelighed1 * 1 Items8.900,00 krSpecifikationer:More
Specifications
Cat. No.CONSD292GrænsefladeRS232Registreringsintervaller4 s - 24 hVægt12 kgB×D×H480×250×130 mmSpænding210 - 250 V
Accessories
Produktinformation
- Katalog #TilgængelighedPrice
- Module pH/MV/Ion/O2
Produktinformation
- Katalog #TilgængelighedPrice
- Hvidt frontpanel til dækning af ubrugte modulpladserHvidt frontpanel til dækning af ubrugte modulpladserCONSD299Log ind for tilgængelighed1 * 1 Items - 433,00 kr
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".