Offers precise point-of-use chemical flow control and is designed for point-of-use blending and dispense applications requiring medium to high flow rates (2,5 to 40 L/min).

  • Most accurate in bubble prone media vs. other commonly used technologies
  • Integral pressure transducer for simultaneous dual output - flow and pressure
  • Compact footprint for space savings and easy installation
  • High repeatability for superior process control

The InVue Integrated Flow Controller, NT6520 (2,5 to 40 L/min) combines our differential pressure based flowmeter and leading-edge control valve technology to create a closed-loop flow controller ideal for: Critical dispense applications, Chemical spiking and blending, On-demand chemical mixing and Higher flow applications such as bulk delivery or tool liquid dispense.

Materials of construction:
Wetted parts: Body, valve diaphragms: PTFE
Sensor interface: CTFE or PFA
Primary O-ring: Perfrez® PXC Ultra
Nonwetted parts: Polypropylene, PVDF, Viton®, polyurethane, and nylon

Specifications for Product Family

Specifikationer

  • Catalog No:
  • ENTE6520T7F4B12KP7
  • ENTE6520T8F6B12AP7
  • ENTE6520T8F6B12KP7
  • Maks. tryk:
  • 690 kPa
  • 690 kPa
  • 690 kPa
  • Responstid:
  • <3 seconds
  • <3 seconds
  • <3 seconds
  • Elektrisk forbindelse:
  • 24 VDC (±10%) @ 1,2 Å
  • 24 VDC (±10%) @ 1,2 Å
  • 24 VDC (±10%) @ 1,2 Å
  • Enclosure rating:
  • IP 64
  • IP 64
  • IP 64
  • Input signal:
  • 4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
  • 4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
  • 4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
  • Maks. driftstemperatur:
  • 10...65 °C
  • 10...65 °C
  • 10...65 °C
  • Reproducerbarhed:
  • ±0,5% of full scale
  • ±0,5% of full scale
  • ±0,5% of full scale

Specifikationer

Product Family Options

Produktinformation

  • Produktion
    Tilgængelighed
    Price
  • ENTE6520T7F4B12KP7
    InVue® integrated flow controller (IFC) NT6520, 12,7 mm Flaretek tubing fitting, 0 - 10 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, batch setpoint input signal, CTFE Sensor interface
    InVue® integrated flow controller (IFC) NT6520, 12,7 mm Flaretek tubing fitting, 0 - 10 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, batch setpoint input signal, CTFE Sensor interface
    Two 4 - 20 mA electrically isolated outputs, one for flow and one for pressure
    Log ind for tilgængelighed
    Log ind for tilgængelighed
    1 * 1 Items
    1 * 1 Items

    Specifikationer:
    More
    Specifications
    Cat. No.
    ENTE6520T7F4B12KP7
    Maks. tryk
    690 kPa
    Responstid
    <3 seconds
    Elektrisk forbindelse
    24 VDC (±10%) @ 1,2 Å
    Enclosure rating
    IP 64
    Input signal
    4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
    Maks. driftstemperatur
    10...65 °C
    Reproducerbarhed
    ±0,5% of full scale
  • ENTE6520T8F6B12AP7
    InVue® integrated flow controller (IFC) NT6520, 19,05 mm Flaretek tubing fitting, 0 - 20 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, continuous setpoint input signal, CTFE Sensor interface
    InVue® integrated flow controller (IFC) NT6520, 19,05 mm Flaretek tubing fitting, 0 - 20 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, continuous setpoint input signal, CTFE Sensor interface
    Two 4 - 20 mA electrically isolated outputs, one for flow and one for pressure
    Log ind for tilgængelighed
    Log ind for tilgængelighed
    1 * 1 Items
    1 * 1 Items

    Specifikationer:
    More
    Specifications
    Cat. No.
    ENTE6520T8F6B12AP7
    Maks. tryk
    690 kPa
    Responstid
    <3 seconds
    Elektrisk forbindelse
    24 VDC (±10%) @ 1,2 Å
    Enclosure rating
    IP 64
    Input signal
    4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
    Maks. driftstemperatur
    10...65 °C
    Reproducerbarhed
    ±0,5% of full scale
  • ENTE6520T8F6B12KP7
    InVue® integrated flow controller (IFC) NT6520, 19,05 mm Flaretek tubing fitting, 0 - 20 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, batch setpoint input signal, CTFE Sensor interface
    InVue® integrated flow controller (IFC) NT6520, 19,05 mm Flaretek tubing fitting, 0 - 20 L/min flow range, FEP-jacketed 304,8 mm pigtail electrical cable, 4 - 20 mA, batch setpoint input signal, CTFE Sensor interface
    Two 4 - 20 mA electrically isolated outputs, one for flow and one for pressure
    Log ind for tilgængelighed
    Log ind for tilgængelighed
    1 * 1 Items
    1 * 1 Items

    Specifikationer:
    More
    Specifications
    Cat. No.
    ENTE6520T8F6B12KP7
    Maks. tryk
    690 kPa
    Responstid
    <3 seconds
    Elektrisk forbindelse
    24 VDC (±10%) @ 1,2 Å
    Enclosure rating
    IP 64
    Input signal
    4 - 20 mA, 0 - 10 VDC, 0 - 5 VDC
    Maks. driftstemperatur
    10...65 °C
    Reproducerbarhed
    ±0,5% of full scale