This benchtop meter is ideal for a wide range of applications and advanced pH and conductivity analysis in the lab. It offers two measuring channels allowing users to measure pH and conductivity simultaneously or view each channel separately.

  • Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
  • Measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
  • Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
  • Calibration log stores ten most recent calibrations
  • Non volatile meter memory ensures your data and settings are protected, even with loss of power
  • Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
  • Flexible power options with universal power adapter or optional AA batteries

IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.

Measure pH, mV, relative mV or ORP with temperature on channel one and measure conductivity, TDS, salinity or resistivity with temperature on channel two.

Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values. Perform up to a five point conductivity calibration. Calibration editing option allows individual points to be fixed without a full recalibration. Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate.

Use linear, non linear, EP (USP) or off conductivity temperature compensation with 5, 10, 15, 20 or 25 °C reference temperatures.

Certifications: CE, TUV 3-in-1 and FCC Class A certifications.

Delivery information: Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable, meter test certificate and 3-year replacement warranty.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 013005MD DuraProbe 4-cell (K=0,475) epoxy-body conductivity sensor, ROSS pH buffer and storage solution kit and Orion 1413 µS conductivity standard (5× 60 ml).

Specifications for Product Family

Specifikationer

  • Catalog No:
  • 665-0272
  • 665-0271
  • Model:
  • A215
  • A215
  • pH - Område:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH - Aflæsningsinterval:
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • pH - Nøjagtighed:
  • ±0,002
  • ±0,002
  • pH - Kalibrering:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV - Område:
  • ±2000,0
  • ±2000,0
  • mV - Aflæsningsinterval:
  • 0,1
  • 0,1
  • mV - Nøjagtighed:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • Konduktivitetsområde:
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • Konduktivitetsopløsning:
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • Konduktivitetsnøjagtighed:
  • 0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
  • 0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
  • Konduktivitetscellekonstant:
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • Konduktivitetskalibrering:
  • Up to 5 points
  • Up to 5 points
  • Modstand - Område:
  • 2 Ω/cm - 100 MΩ/cm
  • 2 Ω/cm - 100 MΩ/cm
  • Modstand - Nøjagtighed:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Resistivity resolution:
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • Salinitet - Område:
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • Salinitet - Aflæsningsinterval:
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • Salinitet - Nøjagtighed:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS - Område:
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • TDS - Aflæsningsinterval:
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • TDS - Nøjagtighed:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Temperaturinterval:
  • –5,0...+105,0 °C
  • –5,0...+105,0 °C
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,1 °C
  • ±0,1 °C
  • Temperaturkompensation:
  • Linear, non linear nLFn, non linear nLFu, EP (USP), off
  • Linear, non linear nLFn, non linear nLFu, EP (USP), off
  • Sensortype:
  • DuraProbe 4-cell conductivity sensor
  • DuraProbe 4-cell conductivity sensor
  • Display:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Battery life:
  • 800 h
  • 800 h
  • Strømforsyning:
  • AC adapter or 4 AA batteries
  • AC adapter or 4 AA batteries
  • Overensstemmelse:
  • IP 54
  • IP 54
  • Operating temperature range:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Datalog - Log-funktion:
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Datalog Kapacitet:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • IP rating:
  • IP 54
  • IP 54
  • Tilslutninger:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • Output:
  • RS232, USB
  • RS232, USB
  • Referencetemperatur:
  • 5 / 10 / 15 / 20 / 25 °C
  • 5 / 10 / 15 / 20 / 25 °C
  • Input:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Antal kanaler:
  • 2
  • 2
  • Kalibrering:
  • pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
  • pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
  • Kalibreringspunkter:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • B×D×H:
  • 240×180×110 mm
  • 240×180×110 mm
  • Vægt:
  • 0,9 kg
  • 0,9 kg

Specifikationer

Product Family Options

Produktinformation

  • Tilgængelighed
    Price
  • 665-0272
    Bench pH/conductivity meter Orion Star A215, kit incl. ROSS Ultra Triode pH/ATC probe and DuraProbe conductivity cell
    Bench pH/conductivity meter Orion Star A215, kit incl. ROSS Ultra Triode pH/ATC probe and DuraProbe conductivity cell
    Log ind for tilgængelighed
    Log ind for tilgængelighed
    1 * 1 Items
    1 * 1 Items - 26.830,00 kr
    26.830,00 kr
    1 * 1 Items
       26.830,00 kr

    Specifikationer:
    More
    Specifications
    Cat. No.
    665-0272
    Model
    A215
    pH - Område
    –2,000...+20,000
    pH - Aflæsningsinterval
    0,1 / 0,01 / 0,001
    pH - Nøjagtighed
    ±0,002
    pH - Kalibrering
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - Område
    ±2000,0
    mV - Aflæsningsinterval
    0,1
    mV - Nøjagtighed
    ±0,2 mV or ±0,05% of reading, whichever is greater
    Konduktivitetsområde
    0,001 µS/cm - 3000 mS/cm
    Konduktivitetsopløsning
    0,001 μS minimum, auto ranging, up to 4 significant digits
    Konduktivitetsnøjagtighed
    0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
    Konduktivitetscellekonstant
    0,001 - 199,9 cm⁻¹
    Konduktivitetskalibrering
    Up to 5 points
    Modstand - Område
    2 Ω/cm - 100 MΩ/cm
    Modstand - Nøjagtighed
    0,5% of reading ±1 digit
    Resistivity resolution
    1 ohm or 0,1 meg-ohm, auto ranging
    Salinitet - Område
    0,06 - 80,00 psu / 0,05 - 42,00 ppt
    Salinitet - Aflæsningsinterval
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinitet - Nøjagtighed
    0,5% of reading ±1 digit
    TDS - Område
    0,001 - 200,0 ppm
    TDS - Aflæsningsinterval
    0,001 ppm minimum, auto ranging, up to 4 significant digits
    TDS - Nøjagtighed
    0,5% of reading ±1 digit
    Temperaturinterval
    –5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperaturkompensation
    Linear, non linear nLFn, non linear nLFu, EP (USP), off
    Sensortype
    DuraProbe 4-cell conductivity sensor
    Display
    Graphic LCD with backlight
    Battery life
    800 h
    Strømforsyning
    AC adapter or 4 AA batteries
    Overensstemmelse
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Datalog - Log-funktion
    Manual / Automatic with AUTO-READ™
    Datalog Kapacitet
    2000 with date and time stamp
    IP rating
    IP 54
    Tilslutninger
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
    Output
    RS232, USB
    Referencetemperatur
    5 / 10 / 15 / 20 / 25 °C
    Input
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Antal kanaler
    2
    Kalibrering
    pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
    Kalibreringspunkter
    1 point relative mV (RmV) mode, 1 point ORP mode
    B×D×H
    240×180×110 mm
    Vægt
    0,9 kg
  • 665-0271
    Bench pH/conductivity meter Orion Star A215, instrument alone
    Bench pH/conductivity meter Orion Star A215, instrument alone
    Log ind for tilgængelighed
    Log ind for tilgængelighed
    1 * 1 Items
    1 * 1 Items - 17.120,00 kr
    17.120,00 kr
    1 * 1 Items
       17.120,00 kr

    Specifikationer:
    More
    Specifications
    Cat. No.
    665-0271
    Model
    A215
    pH - Område
    –2,000...+20,000
    pH - Aflæsningsinterval
    0,1 / 0,01 / 0,001
    pH - Nøjagtighed
    ±0,002
    pH - Kalibrering
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - Område
    ±2000,0
    mV - Aflæsningsinterval
    0,1
    mV - Nøjagtighed
    ±0,2 mV or ±0,05% of reading, whichever is greater
    Konduktivitetsområde
    0,001 µS/cm - 3000 mS/cm
    Konduktivitetsopløsning
    0,001 μS minimum, auto ranging, up to 4 significant digits
    Konduktivitetsnøjagtighed
    0,5% of reading ±1 digit > 3 μS, 0,5% of reading ±0,01 μS ≤ 3 μS
    Konduktivitetscellekonstant
    0,001 - 199,9 cm⁻¹
    Konduktivitetskalibrering
    Up to 5 points
    Modstand - Område
    2 Ω/cm - 100 MΩ/cm
    Modstand - Nøjagtighed
    0,5% of reading ±1 digit
    Resistivity resolution
    1 ohm or 0,1 meg-ohm, auto ranging
    Salinitet - Område
    0,06 - 80,00 psu / 0,05 - 42,00 ppt
    Salinitet - Aflæsningsinterval
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinitet - Nøjagtighed
    0,5% of reading ±1 digit
    TDS - Område
    0,001 - 200,0 ppm
    TDS - Aflæsningsinterval
    0,001 ppm minimum, auto ranging, up to 4 significant digits
    TDS - Nøjagtighed
    0,5% of reading ±1 digit
    Temperaturinterval
    –5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperaturkompensation
    Linear, non linear nLFn, non linear nLFu, EP (USP), off
    Sensortype
    DuraProbe 4-cell conductivity sensor
    Display
    Graphic LCD with backlight
    Battery life
    800 h
    Strømforsyning
    AC adapter or 4 AA batteries
    Overensstemmelse
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Datalog - Log-funktion
    Manual / Automatic with AUTO-READ™
    Datalog Kapacitet
    2000 with date and time stamp
    IP rating
    IP 54
    Tilslutninger
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
    Output
    RS232, USB
    Referencetemperatur
    5 / 10 / 15 / 20 / 25 °C
    Input
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Antal kanaler
    2
    Kalibrering
    pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option
    Kalibreringspunkter
    1 point relative mV (RmV) mode, 1 point ORP mode
    B×D×H
    240×180×110 mm
    Vægt
    0,9 kg
Accessories

Produktinformation

  • Katalog #
    Til
    Tilgængelighed
    Price
  • Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    662-1140
    Thermo Scientific™ Orion™ Versa Star meters, Orion™ Star A series meters (Star A320, Star A220 and Star A210 series) and legacy Orion™ Star and Star Plus meters
    Log ind for tilgængelighed
    1 * 1 Each - 884,00 kr

Produktinformation

  • Katalog #
    Tilgængelighed
    Price
  • Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    662-1547
    Log ind for tilgængelighed
    1 * 1 Items - 838,00 kr

Produktinformation

  • Katalog #
    Tilgængelighed
    Price
  • Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    ORIOSTARA-HB
    Log ind for tilgængelighed
    1 * 1 Items - 651,00 kr

Produktinformation

  • Katalog #
    Til
    Tilgængelighed
    Price
  • Cable adapter, for connecting the RS232 port of a meter to a USB port
    Cable adapter, for connecting the RS232 port of a meter to a USB port
    ORIO1010005
    Orion™ Versa Star, Orion™ Star A series (A320, A220 + A210 series) and Orion™ Star and Star Plus meters
    Log ind for tilgængelighed
    1 * 1 Items - 1.520,00 kr

Produktinformation

  • Katalog #
    Til
    Tilgængelighed
    Price
  • RS232 cable, for connecting a meter to a PC or printer
    RS232 cable, for connecting a meter to a PC or printer
    ORIO1010053
    Orion™ Versa Star, Orion™ Star A series (A320, A220 + A210 series), Orion™ Dual Star benchtop meters, Orion 3-Star, 4-Star and 5-Star meters
    Log ind for tilgængelighed
    1 * 1 Items - 525,00 kr

Produktinformation

  • Katalog #
    Tilgængelighed
    Price
  • Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    ORIOSTARA-BEA
    Log ind for tilgængelighed
    1 * 1 Items - 1.890,00 kr

Recommendations

Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".

Otherwise, you will receive generic recommendations.