VWR offers a broad line of reagent droppers, diagnostic kits, and antigens and antisera, for aid in identifying a variety of microscopic organisms. The visualization of bacteria by means of staining procedures is an important tool for any microbiologist to have at their disposal, and these carefully standardized and reproducible stain reagents help to ensure accurate and easily interpretable results. Stains are also available to provide early detection of positive blood cultures by fluorescence procedures.
VWR® Q Path® Cytofix, Cytology Fixture
Supplier: VWR Chemicals
Fixative, combining the coagulant qualities of alcohol, to enable a better fixation of nuclear and cytoplasmic elements. The erythrocytes are lysed and, therefore, do not obscure observation of the elements of interest. This fixative can be used according to the Saccomanno method.
Expand 1 Items
VWR® Q Path® Freeze Gel (Glue) Mounting Medium for Cryotomy
Supplier: VWR Chemicals
High viscosity mounting media for cryotomy. Less viscous than O.C.T.
Expand 1 Items
VWR® Q Path® Safemount, Mounting Agents for Microscopy
Supplier: VWR Chemicals
Safemount Q Path® is a mounting medium, supplied in an PET bottle, which is compatible with Safesolv. It glues the coverglass to the slide and fixes the probe in position after staining.
Expand 1 Items
VWR® Fixing Solution
Supplier: VWR Chemicals
Fixing solution with 0,02% formaldehyde and 0,01% citric acid in aqueous solution.
Expand 1 Items
RenLam® M-1 for microscopy, suitable as a embedding medium, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
To be used with SIAL 69571 Ren HY 956 (Hardener for Epoxy Embedding Medium)
Expand 2 Items
Aqueous mounting medium, Fluoroshield™, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Fluoroshield™ is an aqueous mounting medium for preserving fluorescence of tissue and cell smears.
Expand 1 Items
Ren™ HY 956 epoxy embedding medium, hardener, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
to be used with SIAL 78711 RenLam M-1 (Epoxy Embedding Medium)
Expand 2 Items
Fikseringsmidler og reagenser til histologi og cytologi
Supplier: Merck
M-FIX is a fixative spray designed for the wet fixation of gynaecological and non-gynaecological preparations processed in Papanicolaou staining. It contains polyglycols in alcoholic solution and a rapid and secure fixation of specimens is possible.
Expand 2 Items
Hartman’s fixative histological tissue fixative, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Hartman′s fixative, which is also known as Davidson′s Fixative, contains acetic acid, alcohol, and formalin. It is widely used for the preservation of eye, bone marrow, breast, testis, and other tissues for histologic examination
Expand 1 Items
Aqueous mounting medium, Fluoroshield™ with PPD, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Fluoroshield™ with PPD (p-phenylenediamine; 1,4-phenylenediamine) is an aqueous mounting medium for preserving fluorescence of tissue and cell smears.
Expand 1 Items
Araldite® M, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Araldite® is an epoxy resin commonly used for embedding. It is basically free from polymerization damage and the plastic does not sublime in the microscope, hence providing continual support and preservation of fine detail.[1] It is composed of araldite M or CY 212, dodecenyl succinic anhydride, dibutyl phthalate and 2,4,6-tridimethylamine methyl phenol.
Expand 2 Items
Epoxy embedding medium, hardener MNA, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Epoxy embedding medium is generally used for biological tissues during study by electron microscopy. Usually, it consists of three components; Epon 812 resin, an anhydride hardener and an accelerator
Expand 1 Items
Embedding kit JB-4, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
JB-4 is a water-soluble, GMA based, plastic resin kit intended for use in the preparation of embedded samples for high resolution light microscopy. It is a technique now widely used for research and clinical diagnosis. JB-4 yields semi-thin sections (0.5μ-2μ) with excellent morphological preservation.
Expand 1 Items
Afkalker, OSTEOMOLL® og OSTEOSOFT®
Supplier: Merck
Hårdt væv som f.eks. knogler eller tænder og prøver af forkalket væv, f.eks. knoglemarvsbiopsier, kræver speciel forbehandling før rutinebehandlingen i et histologisk laboratorium.
Expand 4 Items
Mounting medium, kaiser's glycerol gelatine, phenol-free
Supplier: Merck
Kaiser's glycerol gelatin is an aqueous mounting medium for microscopy and works well with specimens prepared for enzyme, lipid, and immunohistochemistry determinations.
Expand 1 Items
Aqueous mounting medium, glycerol gelatin, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Glycerol alters the hygroscopic property of gelatin and its permeability to water vapour. Glycerol gelatin or glycerine jelly medium is an aqueous slide mounting media, used for mounting samples in microscopy and histology.
Expand 2 Items
Zinc Formalin Fixative
Supplier: SIGMA ALDRICH MICROSCOPY
Zinc formalin fixative is a non-precipitating fixative. This fixative is compatible with histochemical, immunochemical and special stains. It may be used with automated tissue processors and also in manual methods. The zinc chloride component of the formulation increases the rigidity of cellular components to withstand subsequent processing, sectioning and staining procedures. Tissue specimens initially fixed using 10% neutral buffered formalin solution may be post-fixed using the zinc formalin fixative.
Expand 1 Items
Osteo-Bed Bone embedding kit, Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Suitable for use with large and small mineralized (undecalcified) bone sections. Yields clear, hard blocks for cutting sections. Not water-soluble.
Expand 1 Items
Immersion oil viscosity 150 cSt (lit.), Sigma-Aldrich®
Supplier: SIGMA ALDRICH MICROSCOPY
Immersion Oil has a defined refractive index of about 1,516. It is important that the refractive index (nD) is about 1,5, similar to that of glass. This enables a homogeneous oil immersion to be achieved.
Expand 2 Items
PMA enhancer for Gram negative bacteria solution 5X
Supplier: Biotium
PMA Enhancer for Gram Negative Bacteria was designed to improve PMA- and PMAxx™-mediated discrimination between live and dead gram-negative bacteria.
Expand 1 Items
Tissue-clearing reagent, CUBIC-R+ for animals
Supplier: TCI
Specifications
Appearance: Colorless to Light orange to Yellow clear liquid
Functionality test: to pass test (Remaining fluorescence strength)
Expand 2 Items
VWR® Q Path® DC3, Decalcifier Rapid-Acting
Supplier: VWR Chemicals
Contains a mixture of hydrochloric acid and alcohols with some EDTA.
Expand 1 Items
VWR® HistoChoice®, Clearing agent
Supplier: VWR Chemicals
HistoChoice® clearing agent is a much less hazardous replacement for xylene/toluene.
Expand 2 Items
Mounting medium, ultrakitt, histo grade, J.T.Baker®
Supplier: Avantor
Monteringsmedie for belægning af slides.
Expand 3 Items
VWR® Mollifex™, Softening agent
Supplier: VWR Chemicals
Mollifex™ is used to soak the cut face of paraffin embedded tissue blocks prior to sectioning is useful to facilitate the mechanical process of sectioning.
Expand 1 Items
VWR®, D.F.B (Decalcifying solution - H.K. Kristenson) Histological grade
Supplier: VWR Chemicals
Decalcifier according to Kristenson.
Expand 1 Items
VWR® Q Path® Coverquick, Mounting Agents for Microscopy
Supplier: VWR Chemicals
A range of mounting media for manual and automatic mounting of slides. The Q Path® Coverquick range consists of four different mounting media with different viscosities to meet all microscopy needs. The number after the name indicates increasing viscosity: Q Path® Coverquick 1000 has the lower viscosity (around 260 mPaS) and Q Path® Coverquick 4000 has the higher viscosity (around 920 mPaS).
Expand 5 Items
Cervix fixative, J.T. Baker®
Supplier: Avantor
Microscopy and staining reagents, J.T.Baker®, Cervix spray fixative
Expand 1 Items
Immersion oil, BioChemica
Supplier: PanReac AppliChem
Biochemical grade immersion oil for microscopy.
Expand 1 Items
VWR® Q Path®, Stick on (cellelim) til mikroskopi
Supplier: VWR Chemicals
Glue for improving adherance of histologicals sections to slides. Alternative to albumin-glycerol.