Solid phase extraction cartridges, Oasis® HLB

Supplier: WATERS

Oasis® HLB cartridges contain the Oasis® HLB sorbent, which is a universal polymeric reversed phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol.

Expand 3 Items
Loading...

Analytical HPLC columns, XBridge™ BEH C8

Supplier: WATERS

The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.

Expand 3 Items
Loading...

Analytical HPLC columns, Resolve® C18

Supplier: WATERS

The combination of hydrophobic and silanophilic mechanisms make Resolve® C18 packings highly retentive for polar and non-polar compounds. Resolve® C18 packages are commonly used for agricultural, industrial, chemical and pharmaceutical applications where very retentive surfaces are needed to adsorb polar compounds.

Expand 1 Items
Loading...

Columns, ACQUITY UPLC™ HSS T3

Supplier: WATERS

An universal, silica based bonded phase with ACQUITY HSS T3 sorbents which is used for the separations for polar and non-polar compounds. It is compatibility with 100% of aqueous mobile phase. It exhibit ultra-low MS bleed, scalable and transferable to HPLC separations.

Expand 1 Items
Loading...

Solid phase extraction cartridges, Oasis® WAX

Supplier: WATERS

These Oasis® WAX cartridges contain the WAX sorbent, which is a polymeric reversed phase, weak anion exchange mixed mode sorbent that has been optimised for fast, simple, and highly selective sample preparation of strong acidic compounds.

Expand 1 Items
Loading...

Analytical HPLC columns, XTerra® Phenyl

Supplier: WATERS

XTerra® Phenyl columns are hybrid-based, reversed phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

Expand 1 Items
Loading...

Analytical HPLC columns, SymmetryShield™ RP18

Supplier: WATERS

SymmetryShield™ columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry® C18 ligand.

Expand 7 Items
Loading...

Analytical HPLC columns, XBridge™ BEH Shield RP18

Supplier: WATERS

XBridge™ BEH Shield RP18 columns complement the XBridge™ BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

Expand 3 Items
Loading...

Gel permeation chromatography clean-up columns, Envirogel™

Supplier: WATERS

The Envirogel™ High-Resolution GPC cleanup columns are specifically designed to remove low volatility, high molecular weight interferences such as lipids and natural resins from environmental samples as specified in EPA method 3640A.

Expand 1 Items
Loading...

SPE cartridge, Sep-Pak®

Supplier: WATERS

Specially designed for analysing formaldehyde, other aldehydes and ketones in air.

Expand 1 Items
Loading...

Glycan BEH amide columns, ACQUITY UPLC™

Supplier: WATERS

The ACQUITY UPLC BEH glycan separation technology column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

Expand 3 Items
Loading...

Analytical HPLC columns, XTerra® MS C18

Supplier: WATERS

XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.

Expand 9 Items
Loading...

Analytical HPLC columns, µBondapak® Phenyl

Supplier: WATERS

Column type: HPLC column, µBondapak®, Phenyl, Ø int.: 3,90 mm, Length: 300 mm, Pore size: 125 Å, Particle size: 10 µm

Expand 1 Items
Loading...

Reversed phase HPLC columns, µBondapak® C18

Supplier: WATERS

µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.

Expand 5 Items
Loading...

Analytical HPLC columns, Symmetry® C8

Supplier: WATERS

Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.

Expand 5 Items
Loading...

Columns, ACQUITY UPLC™ CSH C18

Supplier: WATERS

ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.

Expand 3 Items
Loading...

Analytical HPLC columns, XTerra® RP8

Supplier: WATERS

XTerra® RP8 columns are general purpose, hybrid-based, reversed phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

Expand 1 Items
Loading...

Inserts for screw neck vials

Supplier: WATERS

Vial insert, 0,30 ml, Glass, Conical bottom, Non sterile, Cap included: No

Expand 2 Items
Loading...

Reversed phase HPLC columns, Atlantis® dC18

Supplier: WATERS

Atlantis® dC18 columns are universal, silica-based, reversed phase C18 columns that are used for polar compound retention. The Atlantis® dC18 columns feature di-functionally bonded C18 ligands that have been optimised for use with highly aqueous mobile phases, including 100% water.

Expand 8 Items
Loading...

HPLC columns, Waters Spherisorb®

Supplier: WATERS

Spherisorb® is a porous, spherical material with a range of narrow particle and pore size distribution resulting in very efficient chromatographic separations. These columns have industry standard, fixed end-fittings and are available in three particle sizes. For guard columns, use corresponding Spherisorb® guard cartridge with stand-alone holder listed under “Fittings and Accessories'”

Expand 49 Items
Loading...

Guard cartridges, Waters Spherisorb®

Supplier: WATERS

The cartridges are compatible with the Spherisorb® cartridge system. They may also be used in a stand-alone holder or in integral extended cartridge end-fitting.

Expand 11 Items
Loading...

Analytical HPLC columns, SymmetryShield™ RP8

Supplier: WATERS

SymmetryShield™ columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry® C18 ligand.

Expand 3 Items
Loading...

Solid phase extraction cartridges, Sep-Pak® Plus

Supplier: WATERS

These cartridges can used with liquid and gas samples and have the unique capability of reverse flow direction, a useful feature for trace enrichment application.

Expand 3 Items
Loading...

Standard, erbium perchlorate solution, for UV wavelength accuracy check

Supplier: WATERS

Standard for spectrophotometer calibration, UV wavelength accuracy solution (erbium perchlorate)

Expand 1 Items
Loading...

Ion pair reagents for analytical HPLC, PIC®

Supplier: WATERS

Tetrabutylammonium phosphate, PIC A reagent, low UV

Expand 2 Items
Loading...

UPLC columns, ACQUITY UPLC™ BEH C8

Supplier: WATERS

The particals and chemistries of the ACQUITY UPLC columns are used to separate and with maximum speed, sensitivity and resolution without compromise, it produce the ideal combination of ultra performance efficiencies wide complementary selectivities.

Expand 3 Items
Loading...

Guard cartridge holder for HPLC columns

Supplier: WATERS

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3,0; 3,9 and 4,6 mm and a length of 20 mm.

Expand 1 Items
Loading...

Analytical HPLC columns, Nova-Pak® phenyl

Supplier: WATERS

These columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.

Expand 1 Items
Loading...

Accessories for water calorimeters

Supplier: WATERS

Aluminium pans for DSC series

Expand 2 Items
Loading...

Accessories for µBondapak® analytical columns

Supplier: WATERS

End connector kit

Expand 1 Items
Loading...
Sort By