"AGILENT"
GC columns, J&W DB-Dioxin
Supplier: Agilent
DB-Dioxin is specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDD) and dibenzofurans (PCDF).
Expand 2 Items
GC columns, J&W DB-225ms
Supplier: Agilent
DB-225ms is excellent for FAME separations and is bonded, cross-linked, and operates from 40 to 240 °C.
Expand 4 Items
Capillary columns, DB-FFAP
Supplier: Agilent
These columns are designed for the analysis of volatile fatty acids and phenols.
Expand 37 Items
GC columns, J&W DB-5.625
Supplier: Agilent
DB-5.625 is specially processed to exhibit excellent inertness for EPA semivolatile methods 625, 1625, 8270, and CLP protocols.
Expand 8 Items
GC columns, J&W DB-5ht
Supplier: Agilent
DB-5ht is a nonpolar column specially processed for an extended temperature limit of 400 °C.
Expand 10 Items
GC columns, J&W DX-1 and DX-4
Supplier: Agilent
DX-Series of GC columns, the polyethylene glycol (PEG) DX-1 and DX-4 columns, deliver excellent performance over a wide temperature range.
Expand 5 Items
J&W DB-608 GC columns
Supplier: Agilent
DB-608 is specifically designed for the analysis of chlorinated pesticides and PCBs and is suitable for use in EPA methods 608, 508, and 8080.
Expand 4 Items
Capillary columns, DB-WAXetr
Supplier: Agilent
DB-WAXetr is a high polarity polyethylene glycol (PEG) column for the analysis of alcohols, solvents, benzenes, styrenes, and organic acids, among others.
Expand 30 Items
GC columns, J&W DB-1701P
Supplier: Agilent
DB-1701P is bonded, cross-linked and solvent rinsable, delivering excellent performance in the analysis of organochlorine pesticides.
Expand 5 Items
GC columns, J&W DB-502.2
Supplier: Agilent
Agilent JW DB-502.2 columns deliver excellent peak shapes for EPA method 502.2 and are available in 105 m lengths for volatiles analysis.
Expand 2 Items
DB-TPH GC columns, J&W
Supplier: Agilent
DB-TPH is specifically designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and leaking underground fuel tanks (LUFT).
Expand 1 Items
GC columns, DB-35ms, J&W
Supplier: Agilent
DB-35ms offers excellent inertness for active compounds while providing very low-bleed characteristics. They are ideal for confirmational analyses.
Expand 6 Items
J&W DB-ALC1 and DB-ALC2 GC columns
Supplier: Agilent
DB-ALC1 and DB-ALC2 results are complete in just two minutes, reducing run time by one-third compared to other blood alcohol analysis columns.
Expand 6 Items
GC column, J&W DB-MTBE
Supplier: Agilent
Agilent provides the DB-MTBE GC column with a low polarity stationary phase which resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation.
Expand 1 Items
J&W DB-1 GC columns, megabore
Supplier: Agilent
DB-1 is a reliable, cross-linked and non-polar column with low bleed and a high temperature limit, delivering superb performance for general purpose applications.
Expand 23 Items
GC columns J&W DB-5ms EVDX
Supplier: Agilent
DB-5 ms EVDX columns provide consistent retention and peak shapes and are specially configured and tested for drugs of abuse confirmation.
Expand 1 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.



