Mini power supply, EV245
Über diesen Artikel
Recommended for mini horizontal and vertical gels.
- Manual programming allows voltage, current, power and time to be set for a routine electrophoresis run parameters can be changed temporarily without interrupting the run
- Timer operation: the microcomputer will automatically terminate the run and sound an alarm when the count down to the selected value is complete
- Automatic recovery after power failure: after a mains power failure the instrument will automatically continue the run for the remaining time
- The unit has constant voltage, constant current and constant power capabilities with automatic cross-over and shows which parameter is kept constant
: Supplied with instruction manual and mains lead.
0 mögliche Produktvariationen vorhanden
Product Details & Documents
Recommended for mini horizontal and vertical gels.
- Manual programming allows voltage, current, power and time to be set for a routine electrophoresis run parameters can be changed temporarily without interrupting the run
- Timer operation: the microcomputer will automatically terminate the run and sound an alarm when the count down to the selected value is complete
- Automatic recovery after power failure: after a mains power failure the instrument will automatically continue the run for the remaining time
- The unit has constant voltage, constant current and constant power capabilities with automatic cross-over and shows which parameter is kept constant
: Supplied with instruction manual and mains lead.
Spezifikationen für diese Produktfamilie
Spezifikationen:
- Catalog No:
- CONSEV1450-UK
- CONSEV1450-CH
- Model:
- EV245
- EV245
- Voltage:
- 0 - 400 V
- 0 - 400 V
- Current:
- 0 - 500 mA
- 0 - 500 mA
- Power requirements:
- 210 - 250 V AC; 50/60 Hz; 75 W
- 210 - 250 V AC; 50/60 Hz; 75 W
- Display:
- LCD, 2×16 characters
- LCD, 2×16 characters
- Programs:
- 9×9 set of parameters
- 9×9 set of parameters
- Parameter range (full scale):
- 1 - 100%
- 1 - 100%
- Min. load resistance:
- 30 (Ω)
- 30 (Ω)
- Overload detection:
- Yes
- Yes
- Ground leakage detection:
- Yes
- Yes
- Ambient temperature:
- 0...40 °C
- 0...40 °C
- Relative humidity:
- 0 - 95 %, non-condensing
- 0 - 95 %, non-condensing
- W×D×H:
- 240×200×130 mm
- 240×200×130 mm
- Load detection:
- On/off, programmable
- On/off, programmable
- Output:
- 3 in parallel, 4 mm sockets
- 3 in parallel, 4 mm sockets
- Timer:
- 0 - 99 h, 59 minutes
- 0 - 99 h, 59 minutes
- Weight:
- 3 kg
- 3 kg