Capillary columns, PLOT
About this item
Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 to C5 hydrocarbons in a main stream of C1 to C5 hydrocarbons.
- High analytical capacity improves efficiency
- No need for sub-ambient cooling simplifies operation
- Choice of two polarities for a broad range of applications
These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, the CP-Al₂O₃ PLOT column offers increased selectivity and allows all C1 to C5 hydrocarbon isomers to be separated.
Aluminium oxide PLOT columns are deactivated using very small salt crystals, providing a reproducible and stable deactivation up to 200 °C. Depending on the type of deactivation salt, the CP-Al₂O₃ PLOT column will show a particular selectivity. The KCl salt results in a relatively apolar Al₂O₃ surface, while Na₂SO₄ deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer.
10 Options Available Below
Product Details & Documents
Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 to C5 hydrocarbons in a main stream of C1 to C5 hydrocarbons.
- High analytical capacity improves efficiency
- No need for sub-ambient cooling simplifies operation
- Choice of two polarities for a broad range of applications
These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, the CP-Al₂O₃ PLOT column offers increased selectivity and allows all C1 to C5 hydrocarbon isomers to be separated.
Aluminium oxide PLOT columns are deactivated using very small salt crystals, providing a reproducible and stable deactivation up to 200 °C. Depending on the type of deactivation salt, the CP-Al₂O₃ PLOT column will show a particular selectivity. The KCl salt results in a relatively apolar Al₂O₃ surface, while Na₂SO₄ deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer.
Product Family Options
CP-Aluminium oxide/Sodium sulfate UltiMetal
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP6968Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 ST1 950,00 €
CP-Aluminium oxide/Potassium chloride
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP7576Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary4,00 µm0,25 mm25 mLog in for availability1 * 1 ST849,00 €
- VARICP7577Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary4,00 µm0,25 mm50 mLog in for availability1 * 1 ST1 460,00 €
- VARICP7511Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm10 mLog in for availability1 * 1 ST513,00 €
- VARICP7515I5Temperature limits -100 to 200/200 °C, 5 in cageTemperature limits -100 to 200/200 °C, 5 in cageCapillary5,00 µm0,32 mm25 mLog in for availability1 * 1 ST1 780,00 €
- VARICP7515Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm50 mLog in for availability1 * 1 ST1 580,00 €
- VARICP7519Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm50 mLog in for availability1 * 1 ST913,00 €
- VARICP7517Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm25 mLog in for availability1 * 1 ST849,00 €
- VARICP7518Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 ST1 630,00 €
CP-Aluminium oxide/Potassium chloride UltiMetal
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP6918Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 ST1 950,00 €