You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Analytical HPLC columns, Ultra Cyano (USP L10)
Supplier: Restek
These analytical HPLC columns with spherical shaped traditional monomeric cyanopropylsilane are well suitable for the analysis of protonated bases and also useful for confirmation of analysis on a C18 or C8 columns.
Expand 72 Items
Capillary columns, Rtx®-5MS (fused silica)
Supplier: Restek
General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g. Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance.
Expand 57 Items
Capillary columns, Rtx®-200
Supplier: Restek
General purpose columns for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, glycols and drugs of abuse. Excellent confirmation column with an Rtx®-5 column for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons and chlorophenoxy herbicides.
Expand 55 Items
HPLC columns, Allure® aqueous C18 (USP L1)
Supplier: Restek
Highly retentive and selective phase for separating polar analytes, including polar acidic compounds. Compatible with highly aqueous (upto 100%) mobile phases. Highly base deactivated.
Expand 3 Items
Rxi®-35Sil MS Columns (Fused Silica)
Supplier: Restek
Rxi® fused silica capillary GC columns are designed specifically for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity.
Expand 3 Items
GC Columns, Rt-bDEXse™ (fused silica)
Supplier: Restek
Separations of more than one hundred chiral compounds have been achieved using our unique DEX columns, and DEX columns continue to demonstrate stability after hundreds of temperature program cycles. By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to columns that have pure cyclodextrin stationary phases. 2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane
Expand 2 Items
CarboBlack columns (packed)
Supplier: Restek
Graphitised carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a non silicone liquid phase. CarboBlack C support can hold up to a 1% loading of a non silicone liquid phase.
Expand 47 Items
Preparative HPLC columns, Ultra Biphenyl
Supplier: Restek
These biphenyl columns offer a greater degree of dispersion than conventional phenyls and a greater degree of polarizability than phenyl hexyls, creating higher selectivity and a greater range of usability. Because of these heightened interactions, this column shows substantial increases in retention—especially for dipolar, unsaturated, or conjugated solutes—and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 3 Items
Solid phase extraction cartridges, Resprep®, method specific
Supplier: Restek
Cartridges have been specifically designed to provide consistent and reproducible results for the method or application stated.
Expand 5 Items
Rt®-Alumina BOND/CFC Columns (Fused Silica PLOT)
Supplier: Restek
Restek Rt®-Alumina BOND columns are highly selective for C1 to C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures.
Expand 1 Items
Solid phase extraction cartridges, Resprep®
Supplier: Restek
These cartridges are manufactured using high density polypropylene and have polyethylene frits unless otherwise noted. Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic solvents (e.g., polar contaminants from sample extracts).
Expand 6 Items
Capillary columns, Rtx®-502.2 (fused silica)
Supplier: Restek
Application-specific columns with unique selectivity for volatile organic pollutants. The Rtx®-502.2 column is cited in U.S. EPA method 502.2 and in many gasoline range organics (GRO) methods for monitoring underground storage tanks. For separation of trihalomethanes, ideal polarity for light hydrocarbons and aromatics.
Expand 11 Items
HPLC columns, Viva biphenyl (USP L11)
Supplier: Restek
These biphenyl coulmns have a greater degree of dispersion than conventional phenyls and a greater degree of polarisability than phenyl hexyls, creating higher selectivity and a greater range of usability. With heightened interactions shows substantial increases in retention for dipolar, unsaturated, or conjugated solutes and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 44 Items
UHPLC columns, Pinnacle® DB IBD UHPLC (USP L68)
Supplier: Restek
An intrinsically base-deactivated (IBD) phase, containing a polar group within, or intrinsic to, the hydrocarbon bonded phase. Unique selectivity and a high level of base deactivation, while reducing or eliminating the need for mobile phase additives.
Expand 3 Items
Columns for Organic Acid Analysis
Supplier: TRANSGENOMIC
Ion exclusion is the preferred method for the separation of weakly ionisable species such as organic acids and alcohols.
Expand 3 Items
UHPLC columns, Ultra Aqueous C18 (USP L1)
Supplier: Restek
Aqueous C18 is a rugged, reversed-phase column with a well-balanced retention profile. It can effectively retain more types of solutes than a conventional C18 and is ideal for multicomponent LC-MS analyses. The general-purpose Aqueous C18 boasts high reproducibility and compatibility with many mobile phase conditions - even 100% aqueous. And when used with a gradient, it eliminates the all-too-common issue of multiple compounds eluting near the column void time.
Expand 42 Items
GC columns, Stabilwax-MS (fused silica)
Supplier: Restek
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels. Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
Expand 2 Items
HPLC columns, Ultra IBD (USP L68)
Supplier: Restek
Ultra IBD is a polar-embedded column that acts as a strong hydrogen bonder. With a unique polar group this column is very retentive and selective for acids. It also provides symmetrical peak shape for strong bases. This columns are compatible with 100% aqueous mobile phases and can be used under reversed-phase or HILIC conditions to retain very polar, ionic compounds in highly organic mobile phases.
Expand 39 Items
UHPLC columns, Pinnacle® DB PAH UHPLC
Supplier: Restek
Base-deactivated spherical silica that is optimised for UHPLC stability. Designed to resolve complex mixtures of polycyclic aromatic hydrocarbons (PAHs). Complete resolution of all 16 EPA 610 PAHs, plus two other routinely analyzed PAH compounds, in less than five minutes to greatly reduce run times and increase sample throughput.
Expand 3 Items
OPTI-LYNX™ Micro Trap Cartridges
Supplier: OPTIMIZE TECHNOLOGIES
Combining a versatile selection of packed beds and the use of a convenient quick-connect holder, OPTI-LYNX™ provides numerous options for chromatographers for on-line or off-line sample clean-up and pre-concentration.
Expand 1 Items
Gel permeation chromatography columns, Styragel® HR
Supplier: WATERS
Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.
Expand 7 Items
Analytical HPLC columns, Nova-Pak® C18
Supplier: WATERS
Nova-Pak® C18 columns are general purpose, silica based, reversed phase C18 columns that are based on 4 µm particle technology.
Expand 5 Items
Reversed phase HPLC columns, Atlantis® Silica HILIC
Supplier: WATERS
Atlantis HILIC silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography.
Expand 2 Items
Preparative columns, µBondapak® C18
Supplier: WATERS
µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.
Expand 1 Items
Analytical HPLC columns, XTerra® MS C8
Supplier: WATERS
XTerra® MS C8 columns are general purpose, hybrid-based, reversed phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.
Expand 2 Items
Analytical HPLC columns, Symmetry® C18
Supplier: WATERS
Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.
Expand 13 Items
Analytical HPLC columns, XTerra® RP18
Supplier: WATERS
XTerra® RP18 columns are general purpose, hybrid-based, reversed phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Expand 6 Items
UPLC columns, ACQUITY UPLC™ BEH Shield RP 18
Supplier: WATERS
These columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Expand 2 Items
Analytical HPLC columns, XBridge™ BEH C8
Supplier: WATERS
The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.
Expand 3 Items
Solid phase extraction cartridges, Sep-Pak® Classic
Supplier: WATERS
Silica-based bonded phase with strong hydrophobicity used to adsorb analytes of even weak hydrophobicity from aqueous solutions.