Order Entry
Germany
Orders LinkContactUsLinkComponent
  | Avantor

Chromatography Columns

Chromatography Columns

Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.

  |
 

Gel permeation chromatography columns, Styragel® HR

Supplier: WATERS

Styragel® HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterising samples in the low to mid molecular range where high resolution is critical.

Expand 7 Items
Loading...

Analytical HPLC columns, Symmetry® C18

Supplier: WATERS

Symmetry® C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactivated silica.

Expand 13 Items
Loading...

Analytical HPLC columns, XSelect™ CSH C18

Supplier: WATERS

XSelect™ CSH C18 is a general purpose column that provides alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps to overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed and slow mobile-phase re-equilibration.

Expand 2 Items
Loading...

HPLC columns, YMC-Pack™ ODS-AQ

Supplier: YMC

ODS-AQ is a C18 reversed phase silica based HPLC packing material specifically designed for use in 100% aqueous eluents.

Expand 3 Items
Loading...

Solid phase extraction cartridges, Sep-Pak® Vac

Supplier: WATERS

These cartridges deliver the option of minimum sample preparation. Consists of moulded, high purity PP syringe-barrel bodies with two PE frits to contain the packing material.

Expand 9 Items
Loading...

Sentry guard cartridges, XBridge™

Supplier: WATERS

XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1 to 12). The trifunctionally bonded C18 ligand provides with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent.

Expand 5 Items
Loading...

Analytical HPLC columns, XBridge™ BEH C8

Supplier: WATERS

The XBridge™ BEH C8 sorbent is less retentive compared to the XBridge™ BEH C18 sorbent. The trifunctionally bonded sorbent offers the widest usable pH range (1 to 12), superior low pH stability and ultra-low column bleed.

Expand 3 Items
Loading...

Analytical HPLC columns, Resolve® C18

Supplier: WATERS

The combination of hydrophobic and silanophilic mechanisms make Resolve® C18 packings highly retentive for polar and non-polar compounds. Resolve® C18 packages are commonly used for agricultural, industrial, chemical and pharmaceutical applications where very retentive surfaces are needed to adsorb polar compounds.

Expand 1 Items
Loading...

Analytical HPLC columns, Nova-Pak® C18

Supplier: WATERS

Nova-Pak® C18 columns are general purpose, silica based, reversed phase C18 columns that are based on 4 µm particle technology.

Expand 5 Items
Loading...

Solid phase extraction cartridges, Oasis® HLB

Supplier: WATERS

Oasis® HLB cartridges contain the Oasis® HLB sorbent, which is a universal polymeric reversed phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol.

Expand 2 Items
Loading...

Solid phase extraction cartridges, Sep-Pak® Classic

Supplier: WATERS

Silica-based bonded phase with strong hydrophobicity used to adsorb analytes of even weak hydrophobicity from aqueous solutions.

Expand 1 Items
Loading...

HPLC columns, YMC-Triart, C18 (ODS), 3 µm

Supplier: YMC

YMC-Triart C18 HPLC columns have balanced hydrophobicity and silanol activity, which makes them for the ideal choice for the separation of acid, neutral, basic and chelating compounds. In addition to that these can also behave as a versatile stationary phase.

Expand 6 Items
Loading...

Analytical HPLC columns, Symmetry® C8

Supplier: WATERS

Symmetry® C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactivated silica.

Expand 5 Items
Loading...

Columns, ACQUITY UPLC™ CSH C18

Supplier: WATERS

ACQUITY UPLC method validation kit includes three batches of chromatographic media (derived from different base particles) to judge the quality, reliability, and consistency of the chromatographic method.

Expand 3 Items
Loading...

Analytical HPLC columns, XTerra® MS C18

Supplier: WATERS

XTerra® MS C18 columns are general purpose, hybrid-based, reversed phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica based column.

Expand 9 Items
Loading...

Reversed phase HPLC columns, µBondapak® C18

Supplier: WATERS

µBondapak® C18 columns are general purpose, silica-based, reversed phase C18 columns that are based on 10 µm particle technology.

Expand 5 Items
Loading...