Injectors and supplies for autosamplers
Supplier: Restek
In-line filter, 7 µm, Siltek treated
Expand 11 Items
Autosampler plunger carrier belt
Supplier: Restek
Autosampler plunger carrier belt for Agilent 7673A and 7673B autosamplers.
Expand 1 Items
GC installation kit
Supplier: Restek
This kit contains the tubing and fittings needed to add an additional GC to lab bench.
Expand 1 Items
FID/NPD adapter fitting
Supplier: Restek
This easy to use adapter fitting is sturdy and made of compact stainless steel.
Expand 1 Items
Autoseal tip assembly for solvent extractor, ASE® 200/300 systems
Supplier: Restek
These assemblies meet original equipment manufacturer's performance.
Expand 4 Items
FID Jet for thermo scientific trace and focus GCs
Supplier: Restek
For use with thermo scientific trace and focus GCs.
Expand 1 Items
FID flow measuring adaptor
Supplier: Restek
This adaptor is suitable for for Agilent 5890/6850/6890/7890 GCs.
Expand 1 Items
Annual service kit for nitrogen generators, Peak Scientific
Supplier: PEAK SCIENTIFIC
Annual service kit for Genius NM32LA, 1022, 1023
Expand 1 Items
PID lamp polishing kit
Supplier: Restek
Photoionisation lamp polishing kit, conatins iron oxide cleaning compound, swabs and instructions
Expand 1 Items
Injector mounting posts
Supplier: Restek
Injector mounting post for Agilent 7673 series autosamplers, for use with 6890 GCs
Expand 2 Items
Pulse dampener, MiniPulse
Supplier: Restek
The MiniPulse pulse damper is ideal for the applications where minimising the total system volume is critical.
Expand 2 Items
Oven temperature sensor assembly for Agilent GCs
Supplier: Restek
The oven sensors works in conjunction with the oven control board to regulate oven temperature.
Expand 2 Items
Carriage motor belt
Supplier: Restek
Carriage motor belt for Agilent 7673A, 7673B and 7673C autosamplers.
Expand 1 Items
FID collector assembly kit
Supplier: Restek
These FID collector assembly kits are made of high-quality stainless steel. Ideal for Agilent 5890/6850/6890/7890 GCs.
Expand 10 Items
Pack in a box kit
Supplier: Restek
A complete column packing system which is used to pack the analytical HPLC columns.
Expand 1 Items
Heater cartridge and platinum resistance thermometer (PRT) sensor for Agilent 5890 GCs
Supplier: Restek
This heater cartridge and PRT sensor can be used with 5890 FID and split/splitless weldments.
Expand 3 Items
Injector adapters
Supplier: Restek
These injector adapters made of stainless steel are ideal for PerkinElmer CAP injector.
Expand 3 Items
Capillary adaptable FID jet
Supplier: Restek
These capillary adaptable FID replacement jets are engineered with a fluted tip to guide the capillary column into the jet.
Expand 4 Items
Universal replacement parts, Omnifit®
Supplier: OMNIFIT
Universal replacement parts for all Omnifit® labware columns which gives complete flexibility to replace lost or worn parts. Compatible with BenchMark, SolventPlus and HiT column ranges.
Expand 21 Items
Split/splitless injection port, EZ Twist Top®
Supplier: Restek
This split/splitless injection port changes inlet liners faster and more easily.
Expand 1 Items
Heater/Sensor assembly
Supplier: Restek
Heater/Sensor assembly for Agilent 6850/6890/7890 GCs use with FID, TCD, NPD, and split/splitless inlets.
Expand 1 Items
Air diverter for Agilent GCs
Supplier: Restek
This air diverter diverts GC exhaust heat up and away from the lab bench.
Expand 1 Items
FID/NPD capillary adapter fitting
Supplier: Restek
FID/NPD capillary adapter fitting, high-quality stainless steel, for Agilent 5890/6850/6890 GC's
Expand 1 Items
Micropacked inlet conversion kits
Supplier: Restek
Micropacked inlet conversion kits are used to convert a capillary GC split/splitless inlet for use with ¹/₁₆" Ext.Ø micropacked columns.
Expand 1 Items
Syringe adaptor kit for single-stage VOC regulator
Supplier: Restek
Used to withdraw sample from a high-pressure cylinder after pressure reduction through the high-purity VOC single-stage regulator.
Expand 1 Items
Packed column inlet adapter kits
Supplier: Restek
Packed column inlet adapter kits center columns perfectly in 6,35 mm injection ports to eliminate bent syringe needles.
Expand 2 Items
Methane cylinder kit for GC
Supplier: Restek
Set the column flow rate by injection the methane and optimising linear velocity is preferred method for establishing reproducible retention times.
Expand 1 Items
Flow splitters, post-column, QuickSplit
Supplier: Restek
Flow splitters with fluid resistor technology eliminate the adjustments to the capillary tubing for optimising split ratio with wide range of interchangeable resistors.
Expand 13 Items
Inlet adaptor kit for dual column installation
Supplier: Restek
Inlet adaptor kit for dual column installation ideal for Agilent capillary injectors, split/splitless fitting for capillary columns.
Expand 1 Items
Septa holder kit
Supplier: Restek
This kit can be used for Thermo Scientific TRACE, 8000, 8000 TOP and Focus SSL. It is made from high quality stainless steel.