Order Entry
Czech Republic
ContactUsLinkComponent
151 results for "Solid Phase Extraction"

151 Results for: "Solid Phase Extraction"

Sort By
ASPEC® 241 system

ASPEC® 241 system

Supplier: GILSON LCMS

This compact ASPEC® system combines positive pressure solid phase extraction (SPE) with small footprint and precise liquid handling for reliable automated SPE applications.

Expand 1 Items
Loading...

J.T.Baker® BAKERBOND spe™ PAH Aqua, SPE Columns for Special Applications

Supplier: Avantor

These solid phase extraction columns are designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from water, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.

Expand 1 Items
Loading...

J.T.Baker® BAKERBOND spe™ PAH Soil, SPE Columns for Special Applications

Supplier: Avantor

This solid phase extraction column is designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from soil, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.

Expand 1 Items
Loading...

Aluminium oxide activated neutral Brockmann Grade I, Supelco®

Supplier: Merck

Brockmann aluminum oxides are suitable for column chromatography and adsorptive filtration. Aluminum oxides are generally used as solid support phases in solid phase extraction (SPE)-based clean-up procedures employed in chromatographic methods

Expand 2 Items
Loading...

J.T.Baker® BAKERBOND spe™ Carbon-Amino, SPE Columns for Special Applications

Supplier: Avantor

BAKERBOND spe™ Amino-Carbon is a double-phase solid extraction column packed with spherical activated carbon (lower layer) and aminopropyl modified silica phase (upper layer) of polar, weak anion properties. Designed for pesticide residue analysis in agricultural product.

Expand 1 Items
Loading...

Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®

Supplier: Merck

Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.

Expand 1 Items
Loading...
AmberChrom™ chloride form, 1X8 50 -100 Mesh, Supelco®

AmberChrom™ chloride form, 1X8 50 -100 Mesh, Supelco®

Supplier: Merck

AmberChrom™ 1X8 50-100 MESH (CL-) Anion is a strongly basic anion exchange resin which is used as an absorbent in solid phase extraction.

Expand 3 Items
Loading...
Extraction unit and drying attachment, LiChrolut®

Extraction unit and drying attachment, LiChrolut®

Supplier: Merck

All the individual steps associated with solid phase extraction can be carried out using the LiChrolut® extraction unit. This transparent and vacuum-suitable unit, made of glass, can be used to prepare up to 12 samples simultaneously.

Expand 3 Items
Loading...

CHROMABOND® WAX SPE Columns

Supplier: MACHEREY-NAGEL

State-of-the-art spherical polymer for highest demands in solid phase extraction. PS/DVB copolymer with secondary and tertiary ammonium modification for mixed-mode SPE with weak anion exchange and reversed-phase properties (WAX).

Expand 2 Items
Loading...
Microplates, 24-well, Whatman™ UNIFILTER®

Microplates, 24-well, Whatman™ UNIFILTER®

Supplier: Whatman products (Cytiva)

The 10 ml UNIFILTER is used with large sample or reagent volumes. Typical applications include biomolecule purification by solid phase extraction and organic synthesis in combinatorial chemistry library generation.

Expand 3 Items
Loading...
Micro extraction by packed sorbent (MEPS™)

Micro extraction by packed sorbent (MEPS™)

Supplier: Trajan Scientific and Medical

Micro Extraction by Packed Sorbent (MEPS™) is a new development in the field of sample preparation by SPE (solid phase extraction). The MEPS™ product consists of two parts, the MEPS™ syringe and the MEPS™ Barrel Insert and Needle assembly (BIN). The MEPS™ approach to sample preparation is suitable for reversed phases, normal phases, mixed mode and ion exchange chemistries. Because MEPS™ BINs can be used for sample volumes as small as 10 µl it makes them particularly well suited to on-line use with LC-MS analysis of volume limited samples.

Expand 7 Items
Loading...

Organic reference standard, 4-Hydroxy-4-methyl-2-pentanone, analytical standard, Supelco®

Supplier: Merck

4-Hydroxy-4-methyl-2-pentanone may be used as an internal standard in the analysis of volatile odor-active compounds present in wine using solid phase extraction with gas chromatography (SPE-GC).

Expand 1 Items
Loading...
ASPEC® 274 system

ASPEC® 274 system

Supplier: GILSON LCMS

This ASPEC® system for positive pressure solid phase extraction (SPE) automation maximises throughput by processing up to four samples in parallel. With its small footprint and multiple probes, it is the ideal choice for reproducible and efficient sample cleanup for clinical, forensic, doping, food, and environmental testing labs.

Expand 1 Items
Loading...

Solid phase microextraction fibers

Supplier: VARIAN

Solid phase microextraction (SPME) is a technique for extracting analytes from solid, liquid or gaseous samples by adsorbing them onto the SPME fiber and then desorbing them into an inlet, either on a gas chromatograph (GC) or an HPLC system. SPME is amenable to automation using an autosampler or it can be performed manually as well.

Expand 31 Items
Loading...

Organic reference standard, Bisphenol E, analytical standard, Supelco®

Supplier: Merck

Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).

Expand 1 Items
Loading...

SPME fibers and arrows

Supplier: Thermo Fisher Scientific

Solid Phase Micro Extraction (SPME) uses a thin-fused silica fiber coated with a sorbent which enables extraction of compounds of interest from liquid or gaseous samples through absorption or adsorption. The fiber is then moved to the injector and the compounds thermally desorbed. The SPME consumables come in two formats SPME fibers and SPME arrows.

Expand 14 Items
Loading...
LH software, TRILUTION®

LH software, TRILUTION®

Supplier: GILSON LCMS

TRILUTION® LH provides a solution for customers using Windows 10 and is a comprehensive software package for seamless automation of all liquid handling and solid phase extraction (SPE) methods. With its intuitive interface, simple drag-and-drop method creation, and application simulation, it combines flexibility and ease of use.

Expand 1 Items
Loading...

SampliQ SPE cartridges

Supplier: Agilent

High quality SampliQ SPE (Solid Phase Extraction) products help the user confidently extract and concentrate samples from complex matrices, ensuring fast, accurate, and reproducible results from the very first step. The SampliQ line includes polymers, silica and non-silica options to meet user's specific SPE needs.

Expand 3 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Metrafenone

Supplier: Merck

Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).

Expand 1 Items
Loading...
Vacuum manifolds, Visiprep

Vacuum manifolds, Visiprep

Supplier: Merck

Solid phase extraction vacuum manifolds allow to simultaneously process up to 12 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover, this ensures the packing will not dry out in some tubes while others finish draining.

Expand 4 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Monolinuron

Supplier: Merck

Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionisation-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).

Expand 1 Items
Loading...
Hazardous Waste Filtration System

Hazardous Waste Filtration System

Supplier: MILLIPORE

If your waste samples contain non-volatile or semi-volatile substances or metals, use this hazardous waste filtration system for saparation, extratction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed specifically for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.

Expand 2 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebutam

Supplier: Merck

Tebutam CRM may also be used as given below:
Optimisation of sample extraction based on QuEChERS and dispersive-solid-phase extraction (d-SPE) clean-up for the multi-residue analysis of 120 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls by liquid and gas chromatography coupled with tandem mass spectrometry (MS/MS)
Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
Determination of 90 pesticides 16 polycyclic aromatic hydrocarbons and 22 polychlorinated biphenyls in honey samples by using QuEChERS combined with dispersive solid-phase extraction (SPME) for sample pre-treatment and liquid chromatography-triple-quadrupole tandem mass spectrometry and gas chromatography-ion-trap tandem mass spectrometry for quantitation
Screening and quantification of 569 pesticides in honeysuckle samples by a combination of ultrahigh-performance liquid chromatography (UHPLC) and quadrupole-Orbitrap high-resolution mass spectrometry
Simultaneous determination of 134 pesticide residues in tea samples using d-SPE extraction with a multi-functional filter (MFF) followed by ultra-high performance liquid chromatography (UPLC) and quadrupole time-of-flight mass spectrometry (TOF-MS).

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Simazine

Supplier: Merck

Simazine CRM may also be used as given below: Development and validation of an ultrasonic-assisted dispersive liquid-liquid microextraction (UA-DLLME) method for sample extraction followed by gas chromatography-mass spectrometry based determination of endocrine-disrupting herbicides in the river and seawater samples. Determination of triazine pesticide residues in samples of apples pears carrots potatoes tomatoes avocado cucumber spinach bananas and oranges by modified QuEChERS and solid-phase extraction (SPE) procedures followed by liquid chromatography-photodiode array (LC-DAD) analysis. Multi-residue analysis of 67 pesticides in olive oil olives and avocado samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) to evaluate various clean-up sorbents. Quantitation of 20 pesticides in eel and shrimp samples by a scheduled multiple reaction monitoring (sMRM) method and QuEChERS with EDTA for sample extraction and purification. Analysis of 35 micropollutants including pesticides in water samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after their solid-phase extraction. Simultaneous quantification of 58 pharmaceuticals and personal care products (PPCPs) and pesticides in water samples by solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME) combined with liquid chromatography-tandem mass spectrometry (LCMS/MS).

Expand 1 Items
Loading...
Nunc™ Universal Tubes, Low Profile

Nunc™ Universal Tubes, Low Profile

Supplier: Thermo Fisher Scientific

Tubes PP/Rack PC/PP. Low profile 5,0 ml externally-threaded universal tubes provide a robust solution for solid or liquid sample storage. Available in configurations that meet your tracking and packaging requirements, the low profile universal tube features 2D barcodes, graduations, a white patch for labelling, and a wide mouth design for easy addition and extraction of sample material. Its externally-threaded design minimises contamination risk in manual handling procedures. The tubes and rack are rated for storage down to vapor phase liquid nitrogen temperatures.

   Sustainable Options Available
Expand 8 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad

Supplier: Merck

Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.

Expand 1 Items
Loading...
Distillation and separation apparatus, behrotest® Kompact

Distillation and separation apparatus, behrotest® Kompact

Supplier: BEHR

Complete sets of equipment for preparation and distillation for commonly required analyses of solid and aqueous samples.

Expand 1 Items
Loading...
SLE plates, 96-well, HyperSep®

SLE plates, 96-well, HyperSep®

Supplier: Thermo Fisher Scientific

HyperSep® SLE provides a fast and effective sample preparation technique for removal of phospholipids from biological matricies. HyperSep® SLE deals with sample preparation of biological matricies via a simple, efficient and an effective protocol, the focus being the removal of interfering phospholipids which cause a number of issues for end point analysis.

Expand 2 Items
Loading...
Glass block manifolds, HyperSep™

Glass block manifolds, HyperSep™

Supplier: Thermo Fisher Scientific

Vacuum manifolds for HyperSep™ SPE columns allow easy processing of samples.

Expand 2 Items
Loading...

C8 octyl - box, 3x 6 ml tubes, 5 mg sampliq solid phase extraction (spe) 1 * 1 items

Supplier: Agilent

C8 octyl - box, 3x 6 ml tubes, 5 mg sampliq solid phase extraction (spe) 1 * 1 items

Expand 1 Items
Loading...
Sort By
Recommended for You