151 Results for: "Solid Phase Extraction"
SPE plates, 96-well, HyperSep™ C8
Supplier: Thermo Fisher Scientific
HyperSep C8 SPE Well Plates and Individual Wells provide excellent performance characteristics for moderately polar analytes. They also offer the potential for polar interactions greater than with C18.
Expand 4 Items
J.T.Baker® BAKERBOND spe™ PCB-N, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction of PCB’s in oil.
Expand 1 Items
SPE plates, 96-well, HyperSep™, C18
Supplier: Thermo Fisher Scientific
Thermo Scientific HyperSep™ C18 SPE 96-well plates and individual wells feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds. The hydrophobic reversed phase material is retentive for most nonpolar compounds, and retains most organic analytes from aqueous matrices.
Expand 5 Items
SPE microelution plates, SOLAµ™
Supplier: Thermo Fisher Scientific
SOLA™μ 96 well SPE micro elution plates are specifically designed to meet the increasingly demanding challenges found within bioanalysis. The micro elution format is uniquely positioned to deliver on bioanalytical needs, but limitations with existing
technological design has prevented significant uptake. The SOLA™μ product eliminates these issues by utilising SOLA technology, which removes the need for frits to retain the sorbent material and, in combination with a macro porous structure, allows for a robust, easily controllable platform for reproducible processing of bioanalytical samples.
Expand 5 Items
Solid phase extraction disk, ENVI™-18
Supplier: Merck
Solid phase extraction disks provides faster flow rates and exhibits less clogging than PTFE discs for the extraction of organic contaminants from drinking water samples.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ PCB-A, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction of PCB’s in oil (dirty samples) in combination with SPE silica gel.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ Carbon-Amino, SPE Columns for Special Applications
Supplier: Avantor
BAKERBOND spe™ Amino-Carbon is a double-phase solid extraction column packed with spherical activated carbon (lower layer) and aminopropyl modified silica phase (upper layer) of polar, weak anion properties. Designed for pesticide residue analysis in agricultural product.
Expand 1 Items
Solid phase extraction cartridges, HyperSep™ Phenyl
Supplier: Thermo Fisher Scientific
Solid phase extraction cartridges, HyperSep™ phenyl offer alternative selectivity for retention of basic compounds. They are used for extraction of aromatic compounds and extraction of basic analytes.
Expand 9 Items
Nunc™ Universal Tubes, Low Profile
Supplier: Thermo Fisher Scientific
Tubes PP/Rack PC/PP. Low profile 5,0 ml externally-threaded universal tubes provide a robust solution for solid or liquid sample storage. Available in configurations that meet your tracking and packaging requirements, the low profile universal tube features 2D barcodes, graduations, a white patch for labelling, and a wide mouth design for easy addition and extraction of sample material. Its externally-threaded design minimises contamination risk in manual handling procedures. The tubes and rack are rated for storage down to vapor phase liquid nitrogen temperatures.
Expand 8 Items
LH software, TRILUTION®
Supplier: GILSON LCMS
TRILUTION® LH provides a solution for customers using Windows 10 and is a comprehensive software package for seamless automation of all liquid handling and solid phase extraction (SPE) methods. With its intuitive interface, simple drag-and-drop method creation, and application simulation, it combines flexibility and ease of use.
Expand 1 Items
Empty solid phase extraction columns, CHROMABOND®
Supplier: MACHEREY-NAGEL
Empty and reservoir columns with accessories for solid phase extraction.
Expand 14 Items
Solid phase extraction cartridges, HyperSep™ Cyano
Supplier: Thermo Fisher Scientific
Solid phase extraction cartridges with medium polarity sorbent, ideal for the isolation of polar compounds from non polar matrices.
Expand 7 Items
Aluminium oxide activated neutral Brockmann Grade I, Supelco®
Supplier: Merck
Brockmann aluminum oxides are suitable for column chromatography and adsorptive filtration. Aluminum oxides are generally used as solid support phases in solid phase extraction (SPE)-based clean-up procedures employed in chromatographic methods
Expand 2 Items
Pesticide reference standard, Promecarb, PESTANAL®, analytical standard, Supelco®
Supplier: Merck
Promecarb may be used as a reference standard for the determination of promecarb in water by solid-phase extraction and liquid chromatography coupled with ionspray mass spectrometry.
Expand 1 Items
SPME fibers and arrows
Supplier: Thermo Fisher Scientific
Solid Phase Micro Extraction (SPME) uses a thin-fused silica fiber coated with a sorbent which enables extraction of compounds of interest from liquid or gaseous samples through absorption or adsorption. The fiber is then moved to the injector and the compounds thermally desorbed. The SPME consumables come in two formats SPME fibers and SPME arrows.
Expand 14 Items
Solid phase microextraction fibers
Supplier: VARIAN
Solid phase microextraction (SPME) is a technique for extracting analytes from solid, liquid or gaseous samples by adsorbing them onto the SPME fiber and then desorbing them into an inlet, either on a gas chromatograph (GC) or an HPLC system. SPME is amenable to automation using an autosampler or it can be performed manually as well.
Expand 31 Items
J.T.Baker® BAKERBOND spe™ PAH Aqua, SPE Columns for Special Applications
Supplier: Avantor
These solid phase extraction columns are designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from water, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.
Expand 1 Items
J.T.Baker® BAKERBOND spe™ PAH Soil, SPE Columns for Special Applications
Supplier: Avantor
This solid phase extraction column is designed for the extraction and clean-up of Poly Aromatic Hydrocarbons (PAH) from soil, including the 16 priority pollutant EPA PAH’s and for several applications using different SPE columns.
Expand 1 Items
Specialty solid phase extraction cartridges, Bond Elut™ Carbon/NH₂
Supplier: VARIAN
These specialty solid phase extraction cartridges provide higher retention of small organics, including those that are too polar to retain on C18 or polymeric SPE.
Expand 8 Items
SPE columns, CHROMABOND® CN
Supplier: MACHEREY-NAGEL
CHROMABOND® CN is a cyanopropyl modified silica phase for solid phase extraction.
Expand 2 Items
Solid phase extraction cartridges, Bond Elut™ SPEC
Supplier: VARIAN
SPEC SPE solid phase extraction cartridges available in standard straight barrel tube format, offering flexibility in sample size. Use on any standard vacuum manifold such as the Vac Elut 20 or SPS 24.
Expand 25 Items
Organic reference standard, 4-Hydroxy-4-methyl-2-pentanone, analytical standard, Supelco®
Supplier: Merck
4-Hydroxy-4-methyl-2-pentanone may be used as an internal standard in the analysis of volatile odor-active compounds present in wine using solid phase extraction with gas chromatography (SPE-GC).
Expand 1 Items
QuEChERS Dispersive Solid Phase Extraction (SPE) Kit
Supplier: Thermo Fisher Scientific
The QuEChERS Extraction Kit is designed for the efficient extraction of pesticides from food samples, ensuring compliance with the 2025 China Pharmacopeia.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ Focus
Supplier: VARIAN
Bond Elut™ Focus solid phase extraction cartridges with enhanced polar recovery. Features a unique amide functionalised polar-enhanced sorbent technology that delivers outstanding retention for polar and non-polar analytes.
Expand 4 Items
Organic reference standard, Bisphenol E, analytical standard, Supelco®
Supplier: Merck
Bisphenol E may be used as a reference standard in the determination of bisphenol E in beverages using on-line solid-phase extraction with fast liquid chromatography coupled with tandem mass spectrometry (on-line SPE fast LC-MS/MS).
Expand 1 Items
Microplates, 24-well, Whatman™ UNIFILTER®
Supplier: Whatman products (Cytiva)
The 10 ml UNIFILTER is used with large sample or reagent volumes. Typical applications include biomolecule purification by solid phase extraction and organic synthesis in combinatorial chemistry library generation.
Expand 3 Items
AmberChrom™ chloride form, 1X8 50 -100 Mesh, Supelco®
Supplier: Merck
AmberChrom™ 1X8 50-100 MESH (CL-) Anion is a strongly basic anion exchange resin which is used as an absorbent in solid phase extraction.
Expand 3 Items
Vacuum manifolds, Visiprep
Supplier: Merck
Solid phase extraction vacuum manifolds allow to simultaneously process up to 12 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover, this ensures the packing will not dry out in some tubes while others finish draining.
Expand 4 Items
Flash cartridges, Mega Bond Elut™
Supplier: VARIAN
Flash cartridges for the purification of organic compounds, and also for scale-up, solid phase extraction.
Expand 24 Items
Extraction unit and drying attachment, LiChrolut®
Supplier: Merck
All the individual steps associated with solid phase extraction can be carried out using the LiChrolut® extraction unit. This transparent and vacuum-suitable unit, made of glass, can be used to prepare up to 12 samples simultaneously.