UV/Vis Calibration Standards
The Hellma® calibration standards comply with all necessary standards and regulations and thus offer the highest quality for recalibrating your spectrometer.
DAkkS calibration certificate*
- 30-year warranty
- All sets including relevant reference
- Traceable to NIST or PTB
- Resource-saving and sustainable
-
Compliant
Center height: 8,5 to 20 mm
Exterior dimension (H×W×D):45×12,5×12,5 mm
Hellma® calibration standards are 100% manufactured in Germany.
Compliant: The Hellma® calibration standards comply with the specifications of quality management. systems and pharmacopoeias (e.g. Ph. Eur. and USP) for the highest quality requirements and international comparability of the measurement results.
DAkkS calibration certificate*: Hellma® calibration standards are manufactured in the Hellma Analytics calibration laboratory, which is accredited by DAkkS* according to DIN EN ISO/IEC 17025, and are delivered with a DAkkS calibration certificate*.
Traceability: All measurement results of the Hellma® calibration standards can be traced back to calibration standards measured by the NIST (National Institute of Standards and Technology for Photometric Accuracy) or the PTB (Physikalisch-Technische Bundesanstalt für die Wellenlängengenauigkeit).
Resource-saving and sustainable: Hellma® calibration standards can be easily reused for years and remain in use for a long time. There is no need for repetitive, time-consuming preparation and production of calibration solutions, thus conserving resources, the environment and budget. A sustainable and environmentally friendly alternative!
30-year warranty: We trust in our quality and you can rely on reliable measurement results! If you recalibrate regularly – at least every two years – in the Hellma Analytics calibration laboratory, you will receive a 30-year manufacturer's warranty on all Hellma® calibration standards.
*) Note: Calibration laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025. The accreditation is only valid for the scope of accreditation listed in the document annex D-K-18752-01-00.
: NIST SRM 1930, European Pharmacopoeia, USP 857.
: The set, along with an empty mount, is supplied in a sturdy carrying case.
The Hellma® calibration standards comply with all necessary standards and regulations and thus offer the highest quality for recalibrating your spectrometer.
DAkkS calibration certificate*
- 30-year warranty
- All sets including relevant reference
- Traceable to NIST or PTB
- Resource-saving and sustainable
-
Compliant
Center height: 8,5 to 20 mm
Exterior dimension (H×W×D):45×12,5×12,5 mm
Hellma® calibration standards are 100% manufactured in Germany.
Compliant: The Hellma® calibration standards comply with the specifications of quality management. systems and pharmacopoeias (e.g. Ph. Eur. and USP) for the highest quality requirements and international comparability of the measurement results.
DAkkS calibration certificate*: Hellma® calibration standards are manufactured in the Hellma Analytics calibration laboratory, which is accredited by DAkkS* according to DIN EN ISO/IEC 17025, and are delivered with a DAkkS calibration certificate*.
Traceability: All measurement results of the Hellma® calibration standards can be traced back to calibration standards measured by the NIST (National Institute of Standards and Technology for Photometric Accuracy) or the PTB (Physikalisch-Technische Bundesanstalt für die Wellenlängengenauigkeit).
Resource-saving and sustainable: Hellma® calibration standards can be easily reused for years and remain in use for a long time. There is no need for repetitive, time-consuming preparation and production of calibration solutions, thus conserving resources, the environment and budget. A sustainable and environmentally friendly alternative!
30-year warranty: We trust in our quality and you can rely on reliable measurement results! If you recalibrate regularly – at least every two years – in the Hellma Analytics calibration laboratory, you will receive a 30-year manufacturer's warranty on all Hellma® calibration standards.
*) Note: Calibration laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025. The accreditation is only valid for the scope of accreditation listed in the document annex D-K-18752-01-00.
: NIST SRM 1930, European Pharmacopoeia, USP 857.
: The set, along with an empty mount, is supplied in a sturdy carrying case.
Product Family Options
Glass filter set for checking the wavelength (W) and photometric (A) accuracy
- DescriptionTypeRangePk
- Holmium- and neutral glass, absorptions: 0,25 /0,5/1,0 AbsStandard wavelengths: A: 440; 465; 546,1; 590; 635 nm W: 279; 361; 453; 536; 638 nm1 SET1 * 1 SET46 470,00 Kč
- Holmium- and neutral glass, absorptions: 0,5/1,0 AbsStandard wavelengths: A: 440; 465; 546,1; 590; 635 nm, W: 279; 361; 453; 536; 638 nm1 SET1 * 1 SET37 170,00 Kč
Glass filter set for checking the photometric accuracy
- DescriptionTypeRangePk
- Neutral glass, absorptions: 0,25/0,5/1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 SET1 * 1 SET35 190,00 Kč
- Neutral glass, conforms to NIST SRM 1930, absorptions: 0,3/1,5/2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 SET1 * 1 SET37 170,00 Kč
- Neutral glass, absorptions: 0,25/0,5/1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 SET37 170,00 Kč
- Neutral glass, conforms to NIST SRM 2930, absorptions: 0,04/2,5/3,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 SET35 190,00 Kč
- Neutral glass, absorptions: 0,25/1,0/2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 SET35 190,00 Kč
Glass filter to check the wavelength accuracy
- DescriptionTypeRangePk
- Didymium glassStandard wavelengths: 329, 472, 512, 681, 875 nm1 * 1 KS13 380,00 Kč
- Holmium oxide glassStandard wavelengths: 279, 361, 453, 536, 638 nm1 * 1 KS12 540,00 Kč
Glass filter to check the photometric accuracy
- DescriptionTypeRangePk
- Optical glass, absorptions: 0,04 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 0,25 AbsNG 11Standard wavelengths: 440, 465, 546.1, 590, 635 nm11 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 0,3 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 0,5 AbsNG 5Standard wavelengths: 440, 465, 546.1, 590, 635 nm11 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 0,7 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 1,5 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 2,5 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
- Neutral glass, absorptions: 3,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 * 1 KS12 540,00 Kč
Calibration plate for checking the photometric accuracy
- DescriptionTypeRangePk
- Neutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.25 Abs; Column 5+6: ND with 0.5 Abs; Column 7+8: ND with 1.0 Abs; Column +10: ND with 1.5 Abs; Column 11+12: ND with 2.5 Abs666.013Standard wavelengths: 405, 450, 490, 650 nm11 * 1 KS74 130,00 Kč
Calibration plate for checking the wavelength (W) and photometric (A) accuracy
- DescriptionTypeRangePk
- Neutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.5 Abs; Column 5+6: ND with 1.0 Abs; Column 7+8: ND with 1.5 Abs; Column 9+10: ND with 2.0 Abs; Column 11+12: Holmium glassStandard wavelengths: A: 405, 450, 490, 650 mm W: 279, 361, 453, 536, 638 nm1 * 1 KS83 850,00 Kč
Blank frame
- DescriptionTypeRangePk