Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.

Sort By

Polystyrene standards, GPC/SEC columns calibration

Supplier: VARIAN

Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.

Expand 67 Items
Loading...

Polystyrene standard ReadyCal set Mp 400-2000000, analytical standards for GPC

Supplier: Merck

Set contains 12 different polystyrene standards with Mp ~374, ~1620, ~3420, ~9130, ~18100, ~32500, ~67500, ~128000, ~246000, ~659000, ~1000000, ~2180000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...
Reference substances for GC analysis, Supelco®

Reference substances for GC analysis, Supelco®

Supplier: Merck

Reference substances can be used for the identification of unknown compounds in a gas chromatogram or as standards in quantitative GC analysis. They serve also for the characterisation of GC column properties.

Expand 3 Items
Loading...

Polyethylene glycol Standard ReadyCal Set Mp 200-1200000, for GPC, Supelco

Supplier: Merck

Set contains 10 different polyethylene glycol/polyethylene oxide standards with Mp ~194, ~970, ~2010, ~4450, ~15000, ~22100, ~62000, ~217000, ~490000, ~1190000; always 3 or 4 standards are lyophilised in a 1,5 ml vial (black, blue or yellow); for 1 complete calibration use one of each of the black, blue and yellow vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...

Polymethylmethacrylate standards, GPC/SEC columns calibration

Supplier: VARIAN

Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone and ethyl acetate.

Expand 43 Items
Loading...

Poly(dimethylsiloxane) analytical standard, for GPC

Supplier: Merck

Poly(dimethylsiloxane) [PDMS] is a polymer. It is a stable silicone rubber. It has been used as ion selective membrane for ion-sensitive field-effect transistors, as spring material in accelerometers, elastomer on a tactile sensor and as flexible encapsulation material in decouple sensors.

Expand 1 Items
Loading...

Peptide and protein MALDI-MS calibration kit, ProteoMass™, Supelco®

Supplier: Merck

This kit features a convenient selection of pre-qualified standard peptides, proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionisation (MALDI) mass spectrometers.

Expand 1 Items
Loading...

Programmed test mix, in dichloromethane (varied conc.), certified reference material, Supelco®

Supplier: Merck

This test mix is based on the comprehensive mix developed by Grob (Grob, et al., J. Chromatogr. 156 (1978) p. 1)

Expand 1 Items
Loading...

Poly(acrylic acid sodium salt) analytical standards, for GPC

Supplier: Merck

Poly(acrylic acid sodium salt) is a hydrophilic polymer, which can find wide applications in the production of consumer product like diapers, because of its ability to absorb many more times its mass in water.

Expand 3 Items
Loading...

MALDI validation set polystyrene Mp ~700 - 70000, certified reference material, Supelco®

Supplier: Merck

MALDI Standards are suitable for the validation and comparison of MALDI-ToF instruments. Certificates provide MALDI spectra including Mw, Mn and Mp values of select narrow polymers, which differ in molar mass.

Expand 1 Items
Loading...

Polyethylene glycol Standard ReadyCal Set Mp 102-40′000, for GPC

Supplier: Merck

Set contains 12 different polyethyleneglycol standards with Mp ~106, ~330, ~420, ~600, ~1500, ~2010, ~3120, ~6240, ~8600, ~12000, ~23000, ~40000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations

Expand 1 Items
Loading...

Polyethylene glycol/oxide standards

Supplier: VARIAN

These hydrophilic polymers are suitable for both aqueous SEC and organic GPC using the majority of polar organic solvents. The two types are chemically similar that can be used together across a wider molecular weight range with aqueous and organic polymers.

Expand 58 Items
Loading...

Nonpolar column test mix, certified reference material, Supelco®

Supplier: Merck

Nonpolar Column Test Mix, TraceCERT®, Supelco®, 500 mug/mL in dichloromethane, Certified reference material, Pk Info: ampule of 2 mL

Expand 1 Items
Loading...

Polar column test mix, certified reference material, Supelco®

Supplier: Merck

Polar Column Test Mix, TraceCERT®, Supelco®, 500 mug/mL each component in dichloromethane, Certified reference material, Pk Info: ampule of 2 mL

Expand 1 Items
Loading...

Polystyrene (low molecular) Standard ReadyCal Set M(p) 250-70000 for GPC

Supplier: Merck

Set contains 12 different polystyrene standards with Mp ~266, Mp ~374, Mp~1100, Mp~1920, Mp~2950, Mp ~4870, Mp ~7200, Mp~10400, Mp ~15700, Mp ~19600, Mp ~34800, Mp ~67500; always 4 standards are lyophilised in a 1,5ml vial (yellow, blue or black); for 1 complete calibration use one of each of the yellow, blue and black vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...

Positive electrophoretic mobility standard, NIST-1980

Supplier: LGC Standards PROMOCHEM

This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.

Expand 1 Items
Loading...

Polystyrene film - IR transmission wavelength standards, NIST-1921B

Supplier: LGC Standards PROMOCHEM

NIST-1921B, Polystyrene film - IR transmission wavelength

Expand 1 Items